1、a * - t a a 18 July 1988 MILITARY SPECIFICATION SHEET SCANNER, MECHANICAL MX-9872(V)7/UA This specification sheet is approved for use by USACECOM, Department of the Army, and is available for ilse by Cl Departments and Agencies of the Department of Defense. The complete requirements for procuring th
2、e MX- 9872(V)7/UA Scanner shall consist of this document and MIL-S-49166(ER). 1. SCOPE 1.1 Scope. This specification sheet covers the Mechanical Scanner, MX- The MX-g872(V)7/UA is used on the M-65 9872(V)7/U- augments MIL-S-49166. C-Nite Thermal Imaging System. 1.2 Purpose. The purpose of this speci
3、fication sheet is to modify or expand the contents of MIL-S-49166 to describe the MX-g872(V)7/UA Mechanical Scanner. All the MIL-S-49166 contents apply except as specifically modified herein. specification sheet. Paragraph numbers directly correlate between MIL-S-49166 and this 2. APPLICABLE DOCUMEN
4、TS 2.1 Issues of documents. The following documents of the issue in effect: or date of invitation for bids or request for proposal form a part of this specification to the extent specified herein. SPECIFICATIONS MILITARY DRAWINGS USA Electronics Command Drawings 80063 SM-D-807690 80063 SM-D-657598 8
5、0063 SM-D-773950 - Scanner, Mechanical, MX-9872(V)/UA, General Specifications for - Mechanical Scanner Assembly, MX-9872(V)/UA - Scan-Interlace PL-l403A/UA - Scan-Interlace PL-l403/UA 2.2 Order of precedence. this specification sheet and the references cited herein, the text of this specification sh
6、eet shall take precedence. In the event of a conflict between the text of Beneficial comments (recommendations, additions, deletions) and any pertinent data which may be of use in improving this document should be addressed to: HQ, USA Communications-Electronics Command, ATTN: AMSEL-ED-TO, Fort Monm
7、outh, NJ 07703, by using the self-addressed Standardization Document Imrpovement Proposal (DD Form 1426) appearing at the end of this document or by letter. AMSC N/A FSC 5855 DISTRIBUTION STATET A. ADD roved for public release; distribution is unlimited. THIS DOCUMENT CONTAINS fg PAGES. -. , /- - .
8、Copyright Communications - Electronics Command Provided by IHS under license with CRAINot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-S-49Lbb/7 58 W 99999Ob OLb0343 L m- 3. REQUIREMENTS 3.1 Description. The MX-g872(V)T/UA Scanner, herein known as the MX- 9872(V
9、)7/UA, shall consist of the MIL-S-49166, MX-9872(V)/UA Scanner adjusted for a nominal 30.0 Hz and 8.0 degree scan angle operation. Scanner can be operated with either Scan-Interlace Assembly PL-1403NA (SM-D- 773950) on PL-l403A/UA (SM-D-657598). These two assemblies will be referred to as the Scan-I
10、nterlace Assembly throughout this specification sheet. The MX-l0717(V)7/U 3.2 Construction. The MX-9872(V)7/UA shall be constructed in accordance with drawing 80063 SM-D-807690-4. 3.2.1 Weight. Weight of the MX-9872(V)7/UA shall be 1.90 pounds maximum, 3.6 Performance characteristics. The Characteri
11、stics specified herein shall apply as constructed (3.2). 2:l rear interlace mode while using the Scan-Interlace Assembly. Operation shall be at a nominal 30.0 Hz, 3.6.1 Scan angle and frequency. 3.6.1.1 Variable scan frequency. Not applicable. 3.6.1.2 Specific scan frequency (30.0 HZ) . Scan frequen
12、cy of the MX- . 9872(V)7/UA shall be adjusted to 30.0 + 0.5 Hz. not be greater than + 1.5 Hz from the nominal frequency at +73 + 9 degrees F when exposed to high-and low temperature environmental conditions (see MIL-S- 49166). Scan frequency drift shall 3.6.1.3 Synchronous scan frequency. Not applic
13、able. 3.6.1.4 Scan angle. The scan angle shall be 4.0 + 0.1 degrees in each direction (8.0 + 0.2 degrees total) from a true 45 degree position with respect to the optical axis (DATUM -A- in figure 1 ) . 3.6.2 Interlace. The MX-9872(V)7/U shall operate in a 2:l rear interlace mode. The switching time
14、 shown in figure 1 of MIL-S-49166 shall no, be greater than 3.5 milliseconds (ms) and the average amplitude shall be 1 .O - + 0.2 vp-p. 3.6.2.1 Interlace angle. The interlace solenoid stops and Scan- Interlace Assembly potentiometers shall be used to determine an object space interlace angle of 155
15、- + 15 arc seconds when used with the Scan-Interlace Assembly. 3.6.2.2 Elevation boresight. The scan mirror shall not deviate by more than + 16 arc minutes in elevation from the scanner (DATUM -A- mounting surfaOe). See figure 2. 3.6.2.3 Interlace transducer D.C. offset The interlace position trans-
16、 ducer shall have a D.C. offset of 0.0 - + 0.2 Vdc. Copyright Communications - Electronics Command Provided by IHS under license with CRAINot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-S-LI7Lhb/7 58 a 77777Oh OLb03LI4 3 m 3.6.3 Scan direction. The MX-9872(V)7/
17、UA shall be in accordance with the waveform shapes and phase relationships in figure 3 while operating in the 2:l rear interlace mode. 3.6.4 Power consumption. Power required to operate the MX-9872(V)7/UA connected to the Scan-Interlace Assembly shall not exceed 2,2 watts total. 3.6.5 Scan efficienc
18、y. The MX-g872(V)7/UA scan efficiency shall be a minimum of 75 percent. 3.6.6 Scan jitter in azimuth. Horizontal jitter shall not exceed 62.0 microseconds. 3.7 Environmental conditions. See MIL-S-49166 except as follows: 3.7.4 Shock. See MIL-S-49166 and 3.7.4.1. 3.7.4.1 Shock and scan frequency. Sca
19、n frequency (3.6.1.2) shall return to normal within 0.2 seconds after the MX-9872(V)7/UA is subjected to the operating shock environment. 3.7.5 Vibration. The MX-9872(V)7MA shall not be damaged by vibration over a frequency spectrum at the specified g levels and amplitudes shown in figure 5 for the
20、X axis and as shown in figure 3 of MIL-S-49166 for the Y and i axes. During specified vibration, the average interlace waveform amplitude shown in MIL-S-49166 figure 1 shall not deviate from the average amplitude without vibration by more than 2 50 percent. 4. QUALITY ASSURANCE PROVISION 4.3 First a
21、rticle inspection. See MIL-S-49166. 4.3.2 Test. In addition to the requirements of MIL-S-49166, Table II, the requirements of 3.6.2.1, 3.6.2.2 and 3.6.2.3 shall also be met. of any tests shall constitute failure of first article inspection. Failure 4.5 Quality conformance inspection. 4.5.2 Tests. 4.
22、5.2.1 Group A inspection. In addition to the requirements of MIL-S- 49166, Table III, the requirements of paragraphs 3.6.2.1, 3.6.2.2 and 3.6.2.3 and test paragraphs 4.6.2.1, 4.6.2.2 and 4.6.2.3 shall also be met. of any test shall be cause for rejection of the unit. Failure 4.6 Test methods. Tests
23、shall be performed utilizing the Scan-Interlace Assembly with the MX-9872(V)7/UA. 4.6.1 Scan frequency. 4.6.1.1 Variable scan frequency. Not applicable. 3 Copyright Communications - Electronics Command Provided by IHS under license with CRAINot for ResaleNo reproduction or networking permitted witho
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILS4916671988SCANNERMECHANICALMX9872V7UA 机械 扫描仪 MX9872V7UAPDF

链接地址:http://www.mydoc123.com/p-448077.html