ANSI UL 33-2010 UL Standard for Safety Heat Responsive Links for Fire-Protection Service (Eighth Edition Reprint with Revisions Through and Including April 14 2015)《消防保护服务的热响应链接用安全.pdf
《ANSI UL 33-2010 UL Standard for Safety Heat Responsive Links for Fire-Protection Service (Eighth Edition Reprint with Revisions Through and Including April 14 2015)《消防保护服务的热响应链接用安全.pdf》由会员分享,可在线阅读,更多相关《ANSI UL 33-2010 UL Standard for Safety Heat Responsive Links for Fire-Protection Service (Eighth Edition Reprint with Revisions Through and Including April 14 2015)《消防保护服务的热响应链接用安全.pdf(22页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 33 Heat Responsive Links for Fire- Protection ServiceUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRIGHTED MATERIAL NOT AUT
2、HORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Heat Responsive Links for Fire-Protection Service, UL 33 Eighth Edition, Dated March 9, 2010 Summary of Topics This revision is being issued to indicate the most recent designation of ANSI/UL 33 as
3、 a Reaffirmed American National Standard. Text that has been changed in any manner or impacted by ULs electronic publishing system is marked with a vertical line in the margin. Changes in requirements are marked with a vertical line in the margin and are followed by an effective date note indicating
4、 the date of publication or the date on which the changed requirement becomes effective. The new and revised requirements are substantially in accordance with Proposal(s) on this subject dated February 20, 2015. All rights reserved. No part of this publication may be reproduced, stored in a retrieva
5、l system, or transmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwise without prior permission of UL. UL provides this Standard as is without warranty of any kind, either expressed or implied, including but not limited to, the implied warranties of merchanta
6、bility or tness for any purpose. In no event will UL be liable for any special, incidental, consequential, indirect or similar damages, including loss of prots, lost savings, loss of data, or any other damages arising out of the use of or the inability to use this Standard, even if UL or an authoriz
7、ed UL representative has been advised of the possibility of such damage. In no event shall ULs liability for any damage ever exceed the price paid for this Standard, regardless of the form of the claim. Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold
8、 UL harmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonable attorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronic Standard on the purchasers computer system. The requirements in this Standard are now
9、 in effect, except for those paragraphs, sections, tables, gures, and/or other elements of the Standard having future effective dates as indicated in the note following the affected item. The prior text for requirements that have been revised and that have a future effective date are located after t
10、he Standard, and are preceded by a SUPERSEDED REQUIREMENTS notice. APRIL 14, 2015 UL 33 tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL APRIL 14, 2015 UL 33 tr2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPROD
11、UCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL MARCH 9, 2010 (Title Page Reprinted: April 14, 2015) 1 UL 33 Standard for Heat Responsive Links for Fire-Protection Service The rst, second, and third editions were titled Fusible Links for Fire-Protection Service. First Edition November, 1968 Second
12、 Edition July, 1973 Third Edition March, 1980 Fourth Edition June, 1982 Fifth Edition October, 1987 Sixth Edition October, 1993 Seventh Edition March, 2003 Eighth Edition March 9, 2010 This ANSI/UL Standard for Safety consists of the Eighth Edition including revisions through April 14, 2015. The mos
13、t recent designation of ANSI/UL 33 as an American National Standard (ANSI) occurred on April 13, 2015. ANSI approval for a standard does not include the Cover Page, Transmittal Pages, Title Page, or effective date information. Comments or proposals for revisions on any part of the Standard may be su
14、bmitted to UL at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards Development System (CSDS) at http:/. ULs Standards for Safety are copyrighted by UL. Neither a printed nor electronic copy of a Standard should be altered in any way. All of ULs Sta
15、ndards and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive property of UL. COPYRIGHT 2015 UNDERWRITERS LABORATORIES INC. ANSI/UL 33-2010 (R2015)UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM
16、 UL MARCH 9, 2010 HEAT RESPONSIVE LINKS FOR FIRE-PROTECTION SERVICE - UL 33 2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS INTRODUCTION 1 Scope .4 2 Units of Measurement .4 3 Components 4 4 Undated References
17、5 5 Glossary .5 CONSTRUCTION 6 Temperature Ratings 5 7 Coatings and Platings .6 PERFORMANCE 8 Strength of Heat Responsive Element and Link Assembly Tests 6 8.1 Fusible-alloy and Bi-metallic Types .6 8.2 Glass-bulb types .7 9 Glass-Bulb Thermal Shock Test 8 10 Operating Temperature (Bath) Test 8 11 S
18、ensitivity Oven Heat Test 9 12 High Temperature Exposure Test (90-Day) Heat Responsive Links .13 13 High Temperature Exposure Test for Wax Coated Heat Responsive Links .13 14 Evaporation Test for Wax Coatings .14 15 10-Day Corrosion Test 14 16 30-Day Corrosion Test 14 16.1 General .14 16.2 20 percen
19、t salt spray .15 16.3 Moist hydrogen sulde air mixture test .15 16.4 Moist carbon dioxide sulfur dioxide air mixture test .15 MARKING 17 General 15 APPENDIX A A1 Tolerance limit calculation methods .A1 MARCH 9, 2010 HEAT RESPONSIVE LINKS FOR FIRE-PROTECTION SERVICE - UL 33 3UL COPYRIGHTED MATERIAL N
20、OT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL INTRODUCTION 1 Scope 1.1 These requirements cover heat responsive links used for re-protection service. These links consist of devices intended for installation under load conditions such as for use with automatic re s
21、uppression systems; or automatic closure devices for doors, windows, dampers or smoke relief vents. 1.2 Heat responsive links are categorized by temperature rating, type of coating or plating, minimum and maximum design load, and other factors which may have a bearing on their intended use. 2 Units
22、of Measurement 2.1 Values stated without parentheses are the requirement. Values in parentheses are explanatory or approximate information. 3 Components 3.1 Except as indicated in 3.2, a component of a product covered by this standard shall comply with the requirements for that component. 3.2 A comp
23、onent is not required to comply with a specic requirement that: a) Involves a feature or characteristic not required in the application of the component in the product covered by this standard, or b) Is superseded by a requirement in this standard. 3.3 A component shall be used in accordance with it
24、s rating established for the intended conditions of use. 3.4 Specic components are incomplete in construction features or restricted in performance capabilities. Such components are intended for use only under limited conditions, such as certain temperatures not exceeding specied limits, and shall b
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIUL332010ULSTANDARDFORSAFETYHEATRESPONSIVELINKSFORFIREPROTECTIONSERVICEEIGHTHEDITIONREPRINTWITHREVISIONSTHROUGHANDINCLUDINGAPRIL142015

链接地址:http://www.mydoc123.com/p-439181.html