1、 AMERICAN NATIONAL STANDARD ANSI/ISA-12.13.04-2007 (R2014) Performance Requirements for Open Path Combustible Gas Detectors Approved 26 February 2014 Commitment for Amendments This standard is issued jointly by ISA and FM Approvals (FM). Comments or proposals for revisions on any part of the standar
2、d may be submitted to ISA or FM at any time. Revisions to this standard will be made only after processing according to the standards development procedures of ISA and FM. ISA and FM will issue revisions to this standard by means of a new edition or revised or additional pages bearing their date of
3、issue. ISBN 978-0-876640-68-5 Copyright 2014 By ISA These materials are subject to copyright claims of ANSI and ISA. All rights reserved. Not for resale. Printed in the United States of America. No part of this publication may be reproduced in any form, including an electronic retrieval system, with
4、out the prior written permission of ISA. All requests pertaining to this standard should be submitted to ISA. 2014 FM Approvals LLC. All rights reserved. ISA FM Approvals ANSI/ISA-12.13.04 ANSI/FM 6325 First Edition First Edition Performance Requirements for Open Path Combustible Gas Detectors This
5、page intentionally left blank. 26 February 2014 ANSI/ISA-12.13.04 ANSI/FM 6325-2007 (R2014) 5 General Notes This is the common ISA and FM standard for Performance Requirements for Open Path Combustible Gas Detectors. It is the first edition of ANSI/ISA-12.13.04 and the first edition of ANSI/FM 6325.
6、 ANSI/ISA-12.13.04 and ANSI/FM 6325 contain identical requirements and identical publication dates. The presentation and format of the standards material may differ between the two published standards. This common standard was prepared by ISA and FM Approvals. Effective Date The effective date for I
7、SA and FM Approvals is the date of publication. This page intentionally left blank. 26 February 2014 ANSI/ISA-12.13.04 ANSI/FM 6325-2007 (R2014) 7 Preface (ISA) This preface, as well as all footnotes and annexes, is included for information purposes and is not part of ANSI/ISA-12.13.04. This documen
8、t has been prepared as part of the service of ISA towards a goal of uniformity in the field of instrumentation. To be of real value, this document should not be static but should be subject to periodic review. Toward this end, the Society welcomes all comments and criticisms and asks that they be ad
9、dressed to the Secretary, Standards and Practices Board; ISA; 67 Alexander Drive; P. O. Box 12277; Research Triangle Park, NC 27709; Telephone (919) 549-8411; Fax (919) 549-8288; E-mail: standardsisa.org. The ISA Standards and Practices Department is aware of the growing need for attention to the me
10、tric system of units in general, and the International System of Units (SI) in particular, in the preparation of instrumentation standards. The Department is further aware of the benefits to USA users of ISA standards of incorporating suitable references to the SI (and the metric system) in their bu
11、siness and professional dealings with other countries. Toward this end, this Department will endeavor to introduce SI-acceptable metric units in all new and revised standards, recommended practices, and technical reports to the greatest extent possible. Standard for Use of the International System o
12、f Units (SI): The Modern Metric System, published by the American Society for Testing 10% LFL x 10 meter = 1 LFLmeter. 2.14.6 lower flammable limit (LFL): the volume ratio of combustible gas or vapor in air below which a combustible gas atmosphere will not be formed 2.14.7 upper flammable limit (UFL
13、): the volume ratio of combustible gas or vapor in air above which a combustible gas atmosphere will not be formed 2.15 lower flammable limit meters (LFLm): a unit of measurement for the amount of gas present in the beam. The LFLm represents the size of a gas cloud multiplied by the gas concentratio
14、n within the cloud. See Figure A.1 of Annex A. 2.15.1 lower flammable limit/meters or path average (%LFL(Avg): a unit of measurement for the amount of gas present in the beam over the length of the beam. The %LFL(Avg) represents the size of a gas cloud multiplied by the gas concentration within the
15、cloud divided by the beam length multiplied by 100. See Figure A.2 of Annex A. 2.16 measurement range: the range of measurement of the detector from the lowest indicated reading, usually “the zero point,” to the highest indicated reading, commonly known as “full scale.” A detector may have multiple
16、measurement ranges and some means of selecting the desired range of measurement. 2.17 optical apparatus 2.17.1 gas cell: a sealed enclosure with transparent ends which can be filled with test gases. 16 ANSI/ISA-12.13.04 ANSI/FM 6325-2007 (R2014) 26 February 2014 2.17.2 open path: the path taken by t
17、he optical radiation from the transmitter to the receiver as it traverses an atmosphere through which gases are free to move. 2.17.3 optical radiation: energy emitted by the transmitter in the form of electromagnetic radiation within a specific region or regions of the electromagnetic spectrum, for
18、example ultra-violet, visible, or infrared light. 2.17.4 receiver: an assembly in which the optical detecting element(s) are housed and which may contain associated optical and electrical components. 2.17.5 reflector: a device that returns or reflects light. 2.17.6 transceiver: an assembly in which
19、the optical detecting element(s) and optical source(s) are housed and which may contain associated optical and electrical components. 2.17.7 transmitter: an assembly in which the optical source(s) are housed and which may contain associated optical and electrical components. 2.18 response conversion
20、 data: information, supplied and explained in the gas detection apparatus instruction manual, enabling the apparatus user to determine the concentration of the gas to be monitored that will produce the same response as a known concentration of another gas used for calibration. 2.19 signals and indic
21、ations 2.19.1 fault signal: an audible, visual, or other type of output which provides, directly or indirectly, a warning or indication that the apparatus has been compromised. 2.19.2 beam blocked signal: an audible, visual or other type of output which provides, directly or indirectly, a warning or
22、 indication that the optical path is obscured or that the signal detected is too weak to enable the apparatus to function normally. 2.19.3 inhibition signal: an audible, visual, or other type of output which provides, directly or indirectly, a warning or indication that normal operation has been sus
23、pended. 2.19.4 indicating devices: means for displaying values or states in analog or digital form. 2.20 span: the algebraic difference between the upper and lower values of a range. 2.21 stand-alone control unit: control unit that receives a corresponding relay or signal from stand-alone gas detect
24、or(s) and is intended to provide meter indication, alarm functions, and/or output contacts. 26 February 2014 ANSI/ISA-12.13.04 ANSI/FM 6325-2007 (R2014) 17 2.22 stand-alone detector: a combination transmitter and receiver either integral or remote that produce a relay or signal to be utilized by an
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIISA1213042007PERFORMANCEREQUIREMENTSFOROPENPATHCOMBUSTIBLEGASDETECTORSFIRSTEDITIONPDF

链接地址:http://www.mydoc123.com/p-436901.html