1、Designation: F2105 17 An American National StandardStandard Test Method forMeasuring Air Performance Characteristics of VacuumCleaner Motor/Fan Systems1This standard is issued under the fixed designation F2105; the number immediately following the designation indicates the year oforiginal adoption o
2、r, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers procedures for determining airperformance characterist
3、ics of series universal motor/fan sys-tems used in commercial and household upright, canister, stick,hand-held utility, combination-type vacuum cleaners, andhousehold central vacuum cleaning systems.1.2 These tests and calculations include determination ofsuction, airflow, air power, maximum air pow
4、er, and inputpower under specified operating conditions.NOTE 1For more information on air performance characteristics, seeReferences (1) through (2).21.3 The values stated in inch-pound units are to be regardedas the standard. The values given in parentheses are forinformation only.1.4 This standard
5、 does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety, health, and environmental practices and deter-mine the applicability of regulatory limitations prior to use.1.5 This interna
6、tional standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade (TBT) Com
7、mittee.2. Referenced Documents2.1 ASTM Standards:3E1 Specification for ASTM Liquid-in-Glass ThermometersE177 Practice for Use of the Terms Precision and Bias inASTM Test MethodsE691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test MethodE2251 Specification for Liq
8、uid-in-Glass ASTM Thermom-eters with Low-Hazard Precision LiquidsF431 Specification for Air Performance Measurement Ple-num Chamber for Vacuum Cleaners2.2 AMCA Standard:4210-85 Laboratory Methods of Testing Fans for Rating2.3 IEC Standard:5IEC 62885-2 Surface Cleaning Appliances Part 2: DryVacuum Cl
9、eaners for Household or Similar Use Meth-ods for Measuring the Performance3. Terminology3.1 Definitions:3.1.1 air power, AP, W, nin a vacuum cleaner motor/fansystem, the net time rate of work performed by an air streamwhile expending energy to produce an airflow by a vacuumcleaner motor/fan system u
10、nder specified air resistance condi-tions.3.1.2 corrected airflow, Q, cfm, nin a vacuum cleanermotor/fan system, the volume of air movement per unit of timeunder standard atmospheric conditions.3.1.3 input power, W, nrate at which electrical energy isabsorbed by a vacuum cleaner motor/fan system.3.1
11、.4 model, ndesignation of a group of vacuum cleanermotor/fan systems having the same mechanical and electricalconstruction.3.1.5 population, ntotal of all units of a particular modelvacuum cleaner motor/fan system being tested.3.1.6 repeatability limit (r), nvalue below which theabsolute difference
12、between two individual test results obtainedunder repeatability conditions may be expected to occur with aprobability of approximately 0.95 (95 %).1This test method is under the jurisdiction ofASTM Committee F11 on VacuumCleaners and is the direct responsibility of Subcommittee F11.22 on Air Perfor-
13、mance.Current edition approved Sept. 1, 2017. Published October 2017. Originallyapproved in 2001. Last previous edition approved in 2016 as F2105 16. DOI:10.1520/F2105-17.2The boldface numbers in parentheses refer to the list of references appended tothis test method.3For referenced ASTM standards,
14、visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.4Available from Air Movement and Control Association, Inc., 30 West Univer-sity Dr., Arlingto
15、n Heights, IL 60004-1893.5Available from the IEC webstore, webstore.iec.ch, or American NationalStandards Institute (ANSI), 25 W. 43rd St., 4th Floor, New York, NY 10036.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis internationa
16、l standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
17、13.1.7 repeatability standard deviation (Sr), nstandard de-viation of test results obtained under repeatability conditions.3.1.8 reproducibility limit (R), nvalue below which theabsolute difference between two test results obtained underreproducibility conditions may be expected to occur with aproba
18、bility of approximately 0.95 (95 %).3.1.9 reproducibility standard deviation (SR), nstandarddeviation of test results obtained under reproducibility condi-tions.3.1.10 sample, ngroup of vacuum cleaner motor/fan sys-tems taken from a large collection of vacuum cleaner motor/fansystems of one particul
19、ar model which serves to provideinformation that may be used as a basis for making a decisionconcerning the larger collection.3.1.11 standard air density, std, lb/ft3,natmospheric airdensity of 0.075 lb/ft3(1.2014 kg/m3).3.1.11.1 DiscussionThis value of air density correspondsto atmospheric air at a
20、 temperature of 68F (20C), 14.696 psi(101.325 kPa), and approximately 30 % relative humidity.3.1.12 suction, inches of water, nin a vacuum cleanermotor/fan system, the absolute difference between ambient andsub-atmospheric pressure.3.1.13 test run, ndefinitive procedure that produces thesingular res
21、ult of calculated maximum air power.3.1.14 test station pressure, Bt, inches of mercury, nfor avacuum cleaner motor/fan system, the absolute barometricpressure at the test location (elevation) and test time.3.1.14.1 DiscussionIt is not the equivalent mean sea levelvalue of barometric pressure typica
22、lly reported by the airportand weather bureaus. It is sometimes referred to as theuncorrected barometric pressure (that is, not corrected to themean sea level equivalent value). Refer to 5.4 for additionalinformation.3.1.15 unit, nsingle vacuum cleaner motor/fan system ofthe model being tested.4. Si
23、gnificance and Use4.1 The test results allow the comparison of the maximumair power at the vacuum cleaner motor/fan system inlet underthe conditions of this test method.5. Apparatus5.1 Plenum ChamberSee Specification F431 or IEC62885-2, Section 5.8.3.5.2 Water Manometers, or equivalent instruments.
24、One tomeasure from 0 to 6 in. (152.4 mm) in increments of 0.01 in.(0.254 mm), and one with increments of 0.1 in (2.54 mm) foruse in making measurements above 6 in. (152.4 mm). A singleinstrument having a resolution of 0.01 in. (0.254 mm) over theentire required range may be used instead of two separ
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIASTMF21052017STANDARDTESTMETHODFORMEASURINGAIRPERFORMANCECHARACTERISTICSOFVACUUMCLEANERMOTORFANSYSTEMSPDF

链接地址:http://www.mydoc123.com/p-433017.html