ANSI ASTM D668-2012 Standard Test Methods of Measuring Dimensions of Rigid Rods and Tubes Used for Electrical Insulation《电绝缘用硬条和硬管尺寸规格测量方法》.pdf
《ANSI ASTM D668-2012 Standard Test Methods of Measuring Dimensions of Rigid Rods and Tubes Used for Electrical Insulation《电绝缘用硬条和硬管尺寸规格测量方法》.pdf》由会员分享,可在线阅读,更多相关《ANSI ASTM D668-2012 Standard Test Methods of Measuring Dimensions of Rigid Rods and Tubes Used for Electrical Insulation《电绝缘用硬条和硬管尺寸规格测量方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D668 12Standard Test Methods ofMeasuring Dimensions of Rigid Rods and Tubes Used forElectrical Insulation1This standard is issued under the fixed designation D668; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the ye
2、ar of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 These test methods cover the measurement of thedimensions of all rigid rods and tubes used as electricalinsulat
3、ion, the limitations imposed being those of the sizerange of the more common forms of measuring instrumentsused.1.2 Where the number of tests to be made or the specifica-tions covering the rod or tube justify its use, it is acceptable touse an accurately calibrated “go-and-no-go” ring gage ofsuitabl
4、e size.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Refer
5、enced Documents2.1 ASTM Standards:2D374 Test Methods for Thickness of Solid Electrical Insu-lation (Withdrawn 2013)3D1711 Terminology Relating to Electrical Insulation3. Terminology3.1 Definitions For definitions of terms used in these testmethods refer to Terminology D1711.4. Significance and Use4.
6、1 These test methods are used to measure the dimensionsof the rod or tube to determine conformance with specificationson full lengths or cut lengths. The measurements can also beused for manufacturing control, determination of uniformity,dimensional stability, and physical and electrical properties
7、ofthe rods and tubes.5. Conditioning5.1 Condition specimens prior to testing for at least 48 h at23 6 1 C and 50 6 2 % relative humidity. Perform tests in aircontrolled at that temperature and humidity.6. Method of Measurement6.1 Make all diameter and wall thickness measurements forspecimens with di
8、mensions 300 mm (12 in.) and under inaccordance with the procedure described in Test MethodsD374 as applicable. Close the micrometer or vernier caliperslowly on the specimen until contact is made without appre-ciable distortion of the specimen. The criterion of contact is theinitial development of f
9、rictional resistance to movement of thespecimen between the micrometer or caliper surfaces. Use asteel tape or steel scale for measurement of length and diametergreater than 300 mm (12 in.).7. Length of Rods or Tubes 300 mm (12 in.) and Underin Length7.1 ApparatusAmachinists micrometer or vernier ca
10、liperof suitable size reading to 0.02 mm or 0.001 in.7.2 Test SpecimensSpecimens shall consist of rods ortubes 300 mm (12 in.) or shorter.7.3 ProcedureMeasure the length of the specimen to thenearest 0.02 mm or 0.001 in. Size permitting, make fourmeasurements at points 90 apart around the circumfere
11、nce ofthe specimen.7.4 ReportReport the average of the measurements takenas the length of the rod or tube.8. Length of Rod or Tubes Over 300 mm (12 in.) inLength8.1 ApparatusSteel tape or steel scale of suitable lengthgraduated in 0.5 mm or164 in.8.2 Test SpecimensSpecimens shall consist of rods ort
12、ubes over 300 mm (12 in.) in length, including full lengths.1These test methods are under the jurisdiction of ASTM Committee D09 onElectrical and Electronic Insulating Materials and are the direct responsibility ofSubcommittee D09.07 on Flexible and Rigid Insulating Materials.Current edition approve
13、d Nov. 1, 2012. Published November 2012. Originallyapproved in 1942. Last previous edition approved in 2004 as D668 99(2004).DOI: 10.1520/D0668-12.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandard
14、s volume information, refer to the standards Document Summary page onthe ASTM website.3The last approved version of this historical standard is referenced onwww.astm.org.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700,
15、 West Conshohocken, PA 19428-2959. United States18.3 ProcedureMeasure the length of the specimen to thenearest 0.5 mm or164 in. Size permitting, make four measure-ments at points 90 apart around the circumference of thespecimen.8.4 ReportReport the average of the measurements as thelength of the rod
16、 or tube.9. Diameter of Rods or Outside Diameter of Tubes 300mm (12 in.) and Under in Outside Diameter9.1 ApparatusAmachinists micrometer or vernier caliperreading to 0.02 mm or 0.001 in.9.2 Test SpecimensSpecimens shall consist of tubes 300mm (12 in.) and under in outside diameter or rods of anydia
17、meter.9.3 ProcedureMeasure the outside diameter of the speci-men to the nearest 0.02 mm or 0.001 in. Make four measure-ments at points 45 apart around the circumference at each endand at the middle of the specimen.9.4 ReportReport the average of the twelve measurementsas the outside diameter of the
18、tube or the diameter of the rod.9.4.1 In the case of tubes, report the variation in outsidediameter as the difference between the maximum and mini-mum individual outside diameter readings, together with allmeasurements made.NOTE 1Rods having a diameter greater than 300 mm are generallycommercially a
19、vailable and no standard test procedures have beendeveloped for measuring dimensions of such rods.10. Outside Diameter of Tubes Over 300 mm (12 in.) inOutside Diameter10.1 ApparatusA flat steel tape graduated in steps of 0.5mm or164 in.10.2 Test SpecimenSpecimens shall consist of tubes over300 mm (1
20、2 in.) in outside diameter.10.3 ProcedurePlace the steel tape tightly around theoutside of the tube at a right angle to the long axis, and measurethe circumference to the nearest 0.5 mm or164 in. Calculate theoutside diameter by the following equation:D 5 tape reading/! 2 2t (1)where:D = average out
21、side diameter of tube, mm or in., andt = thickness of tape, mm or in.Make at least three measurements at three different locationson the tube.10.4 ReportReport the average of all measurements as theoutside diameter of the tube.11. Inside Diameter of Tubes 300 mm (12 in.) and Underin Inside Diameter1
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
2000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIASTMD6682012STANDARDTESTMETHODSOFMEASURINGDIMENSIONSOFRIGIDRODSANDTUBESUSEDFORELECTRICALINSULATION

链接地址:http://www.mydoc123.com/p-432447.html