1、 MIL-PRF-32017 m 999990b 20b1)037 bTb m I INCHPOUND I MIL-PRF-320 17 1 December 1997 PERFORMANCE SPECIFICATION REFRIGERATION SYSTEM, ADVANCED DESIGN This specification is approved for use by the Department of the Air Force, and is avails_ for use ail Departments and Agencies of the Department of Def
2、ense. Y 1. SCOPE 1.1 Scope. This specification covers the performance requirements for an Advanced Design Refiigeration (ADR) system consisting of an Insulated Container (IC) and an electrically driven Refiigeration Unit (RU). 2. APPLICABLE DOCUMENTS 2.1 General. The documents listed in this section
3、 are specified in sections 3 and 4 of this specification. This section does not include documents cited in other sections of this specification or those recommended for additional information or as examples. While every effort has been made to ensure the completeness of this list, document users are
4、 cautioned that they must meet all specified requirements documents cited in sections 3 and 4 of this specification, whether or not they are listed. 2.2 Government documents 2.2.1 Standards. The following Government standards form a part of this document to the extent specified herein. Unless otherw
5、ise specified, the issues of these documents are those listed in the issue of the Department of Defense Index of Specifications and Standards (DoDISS) and supplement thereto, cited in the solicitation (6.2). Beneficial comments (recommendations, additions, deletions) and any pertinent data which may
6、 be of use in improving this document should be addressed to: HQ, AFSVA/SVOSR, 10100 Reunion Place, Suite 401, San Antonio, TX 78216-4138 by using the Standardization Document Improvement Proposal (DD Form 1426) appearing at the end of this document or by letter. AMSC NIA FSC 41 10 Provided by IHSNo
7、t for ResaleNo reproduction or networking permitted without license from IHS-,-,- - MIL-PRF-32017 = 9999906 2ObYOL 532 MIL-PRF-320 17 STANDARDS DEPARTMENT OF DEFENSE MIL-STD-209 - Slinging and Tiedown Provisions for Lifting and Tying Down Military Equipment MIL-STD-46 1 - Requirements for the Contro
8、l of Electromagnetic Interference Emissions and Susceptibility MIL-STD-462 - Measurement of Electromagnetic Interference Characteristics MIL-STD-8 1 O - Environmental Test Methods and Engineering Guidelines MIL-STD-1474- Noise Limits for Army Materiel (Metric) MIL-STD-1791- Designing for Internal Ae
9、rial Delivery In Fixed Wing Aircraft (Unless otherwise indicated, copies of the above standards are available fiom the Standardization Documents Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19 1 1 1-5094). 2.2.2 Other Government documents. The following other Government documents fo
10、rm a part of this document to the extent specified herein. Unless otherwise specified, the issues are those listed in the solicitation (see 6.2). DEPARTMENT OF DEFENSE AFSC DH 1-1 1 - AFSC Design Handbook 1-11, Air Transportability (Application for copies should be addressed to ASDENESS, Wright-Patt
11、erson AFB, OH 45433). DEPARTMENT OF TRANSPORTATION (DOT) Code of Federal Regulations Title 49 CFR - Transportation, Parts 450-45 1 (Application for copies should be addressed to the Department of Transportation, Superintendent of Documents, Government Printing Office, Washington, DC 20440). 2 Provid
12、ed by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,- MIL-PRF-32017 m 9999906 2064039 479 m MIL-PRF-32017 2.3 Non-Government publications. The following documents form a part of this specification to the extent specified herein. Unless otherwise specified, the
13、issues of the documents which are DoD adopted are those listed in the issue of DoDISS cited in the solicitation. Unless oherwise specified, the issues of documents not listed in the DoDISS are the issues of the documents cited in the solicitation (see 6.2). NATIONAL FIRE PROTECTION ASSOCIATION (NFPA
14、) Standard No. 70 - National Electrical Code (Application for copies should be addressed to the National Fire Protection Association, One Battery March Park, Quincy, MA 02269-9101). NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION (NEMA) Standards Publication No. 250 - Enclosures for Electrical Equipme
15、nt (Application for copies should be addressed to the National Electrical Manufacturers Association, 1300 No. 17th Street, Suite 1847, Rosslyn, VA 22209). UNDERWRITERS LABORATORIES INC. (U.,) Standard 207 - Refngerant Containing Components and Accessories, Nonelectrical Standard 486 - Wire Connector
16、s and Solder Lugs (Application for copies should be addressed to the Underwriters Laboratories, Inc., 333 Pfmgsten Road, Northbrook, IL 60062-2096). 2.4 Order of precedence. In the event of a conflict between the text of this document and the references cited herein, the text of this document takes
17、precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 First article. When specified (see 6.2), a sample shall be subjected to first article inspection in accordance with 4.1.1. 3.2 ODeratina reauir
18、ements. The ADR system shall satis the following functional, operational and performance requirements. 3.2.1 4-hour operation. The RU shall operate properly with suction and discharge pressures safely controlled. 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license
19、from IHS-,-,- M1L-PRF-320l17 9999906 2ObYO20 190 W MIL-PRF-32017 3.2.2 Heat leakage. Heat Siltration or loss through the IC shall be minimized with an overall U factor not exceeing 15 Btu/hr/“F. 3.2.3 Refrigeration capacity. The RU shall have minimum net capacities of 3,000 Btu/hr at a thermostat se
20、tting of 0F and 5,000 Btu/hr at a thermostat setting of 35F. 3.2.4 Heating capacity. The gross heating capacity of the RU shall not be less than 700 watts at a thermostat setting not less than 45F. 3.2.5 Moisture content and refrigerant leakage. The moisture content of the refrigeration system shall
21、 be kept to a minimum to maintain proper operation of the RU and refrigerant containing components shall be gastight. 3.2.6 Defrosting. The RU shall have a defrost cycle terminated by temperature and automatically initiated by a time control adjustable between 4 and 24 hours. The defrost system shal
22、l produce no less than 6 pounds of condensate within 30 minutes. The defrost system shall have provisions for manual defiost override. 3.2.7 Sdety. The IC shall minimize flammability, and operational, toxic and personnel hazards. 3.2.8 Air circulation. The interior of the IC shall facilitate cold ai
23、r circulation underneath and around items stored in the IC. 3.2.9 Drainacre and watertightness. The IC shall be watertight and capable of being drained with the door open. 3.2.1 O Pressure relief. The IC shall maintain internal pressure equal to outside pressure. 3.2.1 1 Door. The door shall open ou
24、tward and shall be flush with the IC exterior when closed. The door opening shail be a minimum 78 inches in height and 36 inches in width. Exted hardware shall be protected fiom damage. Means shall be provided to hold the door in the full open position. 3.2.12 Door handle and latch. The door shall h
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AIRFORCEMILPRF320171997REFRIGERATIONSYSTEMADVANCEDDESIGN 先进 设计 制冷系统 PDF

链接地址:http://www.mydoc123.com/p-428204.html