AIR FORCE A-A-59237 A-2010 COMPOSITE REPAIR SET AIRCRAFT (DUAL ZONE)《飞行器用组合维修组件(双区式)》.pdf
《AIR FORCE A-A-59237 A-2010 COMPOSITE REPAIR SET AIRCRAFT (DUAL ZONE)《飞行器用组合维修组件(双区式)》.pdf》由会员分享,可在线阅读,更多相关《AIR FORCE A-A-59237 A-2010 COMPOSITE REPAIR SET AIRCRAFT (DUAL ZONE)《飞行器用组合维修组件(双区式)》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、 FSC 4920 Beneficial comments, recommendations, additions, deletions, clarifications, etc. and any other data that may improve this document should be sent to FSC: 4920 - 642 CBSG/GBEA, 460 Richard Ray Blvd, Suite 200, Robins AFB, GA 31098-1813. Since contact information can change, you may want to
2、verify the currency of this address information using the ASSIST Online database at https:/assist.daps.dla.mil/online/. A-A-59237A 11 May 2010 SUPERSEDING A-A-59237 13 June 2003 COMMERCIAL ITEM DESCRIPTION COMPOSITE REPAIR SET, AIRCRAFT (DUAL ZONE) The General Services Administration has authorized
3、the use of this commercial item description (CID), for all federal agencies. 1. Scope. This commercial item description (CID) covers the requirements for a portable, self contained aircraft composite repair set with capability to generate, control, and monitor vacuum pressures and cure temperatures.
4、 This repair set is to be used in the repair and dry-out of aircraft bonded and composite structures. 2. SALIENT CHARACTERISTICS. 2.1 General. The composite repair set shall be a user-friendly unit capable of automatically generating, controlling and monitoring vacuum pressure, cure time and tempera
5、tures. Each set shall include heater blankets, temperature controllers, monitoring devices, a vacuum pump, temperature indicators/recorders, and all necessary cables/connectors to perform part-dryout and composite/metal bonded repairs. The repair set shall have two zones capable of simultaneously op
6、erating totally independent cures of different temperatures, cure times, start/stop times and post or step cures. The repair set shall require only an electrical power source to generate the heat and vacuum required for the repair(s). The repair set shall have the option of using shop air/vacuum or
7、the built-in vacuum source. The set shall include all components, parts and features necessary (with the exception of bagging materials and process materials) to meet the performance requirements specified herein. Included shall be manuals and instructions for all operations. Also a step-by-step vid
8、eo/CD explaining simple operations shall be included. 2.2. Size and Weight. The sum of the length plus width plus height of each container of the repair set shall not exceed 62 inches and shall not weigh more than 55 pounds. The preferred configuration will have the main container the approximate si
9、ze of commercial airline carry-on luggage. INCH-POUND Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59237A 2 2.3 Measuring and indicating devices. All measuring and indicating devices shall have a degrees Fahrenheit (F) scale for measuring temp
10、erature and in inches of mercury (Hg) scale for measuring vacuum. 2.4 Power. The repair set shall operate on power sources of 110-120 VAC 50/60 Hz single phase and 220-240 VAC 50/60 Hz single phase and shall have protection against the inadvertent application of the incorrect power source. The repai
11、r set shall have a 20 amp rating at both 120 VAC/60 Hz and 240 VAC/60 Hz and shall have ground fault protection at both the 120 VAC and the 240 VAC 2.4.1 Steady-state conditions. The repair set shall operate and maintain the specified performance and accuracy within a steady-state voltage tolerance
12、band of 10 percent and within a steady-state frequency tolerance band of 5 percent with no detrimental effect on equipment performance. 2.4.2 Transient-state conditions. The repair set shall not experience alterations of characteristics due to transient-state conditions lasting up 100 milliseconds w
13、hen recovery to the steady-state conditions is within 5 seconds. Operation for transient-state conditions which persist longer than 5 seconds shall be as required for Interruption of source power. 2.5 Temperature controller. The temperature controller shall have the following features: a. Two totall
14、y independently programmable zones. b. There shall be a minimum of 8 thermocouples per zone. The operator shall be able to select one of the thermocouples to be the control thermocouple. If the operator has not assigned a control thermocouple the controller shall automatically control, at a minimum,
15、 the leading (hot) thermocouple. The operator shall specify allowable deviations, both high and low, from the setpoint of any thermocouple. Ability for the operator to select control to average temperature or lagging thermocouple is considered a plus. c. The operator shall specify the high limit. If
16、 the high limit is exceeded, an alarm will sound and power to the blanket will be suspended until the alarm condition is corrected. d. Ascertains the continuity of all thermocouples. e. All thermocouples temperatures shall be viewable to the operator. f. The temperature controller will give a deviat
17、ion alarm if temperature does not properly change over a period of time. g. An “ON/OFF” vacuum switch. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59237A 3 h. A low battery indicator is required if a dead battery will disable the controller o
18、r cause loss of programming data. i. The capability to use controller as a thermocouple reader only. j. There shall be a mechanism to disable user input (e.g. key lock, password). k. An audible alarm with a volume of 80 db weighted sound pressure at a 3 foot distance. Associated with each alarms is
19、a visual alarm indicator of at least 0.18 inch length by 0.18 inch width. The audible alarm has a silence button, however, the visual alarm indicator remains on until the deviation has been eliminated. The audible alarm is able to retrigger for any additional deviations in this mode. The visual and
20、audible alarms reset automatically when the deviations(s) is (are) corrected. The controller prints the problem and time of correction for all alarms. l. Programmable for multi-step cures Stores a minimum of 5 programs of 3 steps. Heat-up and cool-down rates are programmable from 1F/min to 15 F/min.
21、 The operator shall enter number of steps, heat up rates, dwell temperatures, dwell times, cool down rates and alarm conditions (high limit, low limit, low vacuum, etc). Each step includes both ramp and hold segments. Uses the ambient temperature of the repair area as the controller initial set poin
22、t. The program is temperature sensitive so that dwell times begin when the dwell temperature is achieved as monitored by the controlling thermocouple(s). The controller has nonvolatile memory for a period of one year. m. The controller shall have the ability for the program to be changed during the
23、run. Any change must be recorded to the printer. n. The programming must be simple enough as to be obvious, without the need for a manual. o. Accuracy of plus or minus 1/4 % of the actual reading plus the least significant digit. p. Triggers an audible and visible indication at the end of the curing
24、 and remains for a duration of several seconds. q. Visually displays the current controller mode (program or run), the progress of the cure cycle, and heater status. r. Simultaneously displays the repair area temperature as monitored by the control thermocouple, and the programmed set point temperat
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AIRFORCEAA59237A2010COMPOSITEREPAIRSETAIRCRAFTDUALZONE 飞行 器用 组合 维修 组件 双区式 PDF

链接地址:http://www.mydoc123.com/p-427063.html