ASTM E2515-11(2017) Standard Test Method for Determination of Particulate Matter Emissions Collected by a Dilution Tunnel.pdf
《ASTM E2515-11(2017) Standard Test Method for Determination of Particulate Matter Emissions Collected by a Dilution Tunnel.pdf》由会员分享,可在线阅读,更多相关《ASTM E2515-11(2017) Standard Test Method for Determination of Particulate Matter Emissions Collected by a Dilution Tunnel.pdf(15页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E2515 11 (Reapproved 2017)Standard Test Method forDetermination of Particulate Matter Emissions Collected bya Dilution Tunnel1This standard is issued under the fixed designation E2515; the number immediately following the designation indicates the year oforiginal adoption or, in the cas
2、e of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method is applicable for the determination ofparticulate matter emissions from so
3、lid-fuel-burning appli-ances including woodstoves, pellet-burning appliances,factory-built fireplaces, masonry fireplaces, masonry heaters,indoor furnaces, and indoor and outdoor hydronic heaterswithin a laboratory environment.1.2 Analytes will be a particulate matter (PM) with no CASnumber assigned
4、. For data quality objectives, see AppendixX1.1.3 The values stated in SI units are to be regarded asstandard. The values given in parentheses are mathematicalconversions to inch-pound units that are provided for informa-tion only and are not considered standard.1.4 This test method does not purport
5、 to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety, health, and environmental practices and deter-mine the applicability of regulatory limitations prior to use.1.5 This international standard w
6、as developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade (TBT) Committee.2. Referen
7、ced Documents2.1 ASTM Standards:2D2986 Practice for Evaluation of Air Assay Media by theMonodisperse DOP (Dioctyl Phthalate) Smoke Test(Withdrawn 2004)3E2558 Test Method for Determining Particulate MatterEmissions from Fires in Wood-Burning FireplacesE2618 Test Method for Measurement of Particulate
8、Emis-sions and Heating Efficiency of Solid Fuel-Fired HydronicHeating AppliancesE2779 Test Method for Determining Particulate MatterEmissions from Pellet HeatersE2780 Test Method for Determining Particulate MatterEmissions from Wood HeatersE2817 Test Method for Test Fueling Masonry Heaters2.2 AISI D
9、ocument:4AISI 316 Stainless Steel2.3 NIST Document:5NIST Monograph 175 Standard Limits of Error3. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 laboratory environmentthe area or room that is usedfor the storage, weighing, assembly, disassembly, and desicca-tion of filters and r
10、elated equipment (sample recovery andanalysis).3.1.2 particulate matter (PM)all gas-borne matter result-ing from combustion of solid fuel, as specified in the applianceoperation test method, that is collected and retained by thespecified filter and probe system under the conditions of thetest.3.1.3
11、test facilitythe area in which the tested appliance isinstalled, operated, and sampled for emissions.1This test method is under the jurisdiction of ASTM Committee E06 onPerformance of Buildings and is the direct responsibility of Subcommittee E06.54on Solid Fuel Burning Appliances.Current edition ap
12、proved Sept. 1, 2017. Published September 2017. Originallyapproved in 2007. Last previous edition approved in 2011 as E2515 11. DOI:10.1520/E2515-11R17.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMSta
13、ndards volume information, refer to the standards Document Summary page onthe ASTM website.3The last approved version of this historical standard is referenced onwww.astm.org.4Available from American Iron and Steel Institute (AISI), 25 MassachusettsAve., NW, Suite 800, Washington, DC 20001, http:/ww
14、w.steel.org.5Available from National Institute of Standards and Technology (NIST), 100Bureau Dr., Stop 1070, Gaithersburg, MD 20899-1070, http:/www.nist.gov.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard wa
15、s developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.14. Summary o
16、f Test Method4.1 The total flue-gas exhaust from a solid fuel burningappliance is collected along with ambient dilution air with acollection hood. Duplicate sampling trains are used to extractgas samples from the dilution tunnel for determination ofparticulate matter concentrations. Each sample trai
17、n has twoglass fiber filters in series. The samples are withdrawn at aconsistently proportional rate from sampling points located atthe centroid of a sampling tunnel. During sampling, the filtersare maintained at a temperature less than 32 C (90 F). Themass of the sampled particulate matter is deter
18、mined gravi-metrically after the removal of uncombined water. The totalparticulate matter mass collected on the filters and in the probeand front filter housing are multiplied by the ratio of thedilution tunnel flow to sample flow to determine the totalparticulate emissions during a test.4.2 The sam
19、pling system for this test method consists ofduplicate dual-filter dry sampling trains. Both of the particulatesampling trains are operated simultaneously at a sample flowrate not to exceed 0.007 m3/min (0.25 cfm min). The totalparticulate results obtained from the two sampling trains areaveraged to
20、 determine the particulate emissions and are com-pared as a quality control check on the data validity.4.3 The particulate concentration results for each samplingtrain is adjusted by the particulate concentration result from asingle room air sample blank collected and processed the sameas the diluti
21、on tunnel particulate sampling trains described in4.2, except that only one filter is used in the sampling train. Ametering system as described in 6.1.1.4 shall be used todetermine the volume of room air collected. The sample flowrate shall not exceed 0.007 m3/min (0.25 cfm).4.4 Appliances tested by
22、 this test method are to be fueledand operated as specified in appliance-specific test methodssuch as, but not limited to, Test Methods E2558, E2618,E2779, E2780,orE2817.5. Safety5.1 DisclaimerThis test method may involve hazardousmaterials, operations, and equipment. This test method may notaddress
23、 all of the safety problems associated with its use. It isthe responsibility of the user of this test method to establishappropriate safety and health practices and to determine theapplicability of regulatory limitations prior to performing thistest method.6. Equipment and Supplies6.1 Sample Collect
24、ionThe following equipment is re-quired for sample collection:6.1.1 Particulate Sampling TrainTwo separate, completeparticulate sampling trains (also referred to as “samplingtrains”) are required for each test run. The filter face velocityshall not exceed 150 mm/sec (30 ft/min) during the test run.T
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTM E2515 11 2017 Standard Test Method for Determination of Particulate Matter Emissions Collected by Dilution Tunnel

链接地址:http://www.mydoc123.com/p-291247.html