ASTM D8143-17 Standard Test Method for Determination of the EU-8 List of PAH Compounds in Carbon Black.pdf
《ASTM D8143-17 Standard Test Method for Determination of the EU-8 List of PAH Compounds in Carbon Black.pdf》由会员分享,可在线阅读,更多相关《ASTM D8143-17 Standard Test Method for Determination of the EU-8 List of PAH Compounds in Carbon Black.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D8143 17Standard Test Method forDetermination of the EU-8 List of PAH Compounds inCarbon Black1This standard is issued under the fixed designation D8143; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last
2、 revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the qualitative and quantitativedetermination of the EU-8 list of polycyclic aromatic hydro-carbon
3、s (PAH) on carbon black. The EU-8 list of PAHcompounds is given in Table 1.The procedure involves Soxhletextraction with toluene followed by extract analysis using gaschromatography with mass spectrometry (GC/MS). Thismethod is not intended to test for U.S. Food and DrugAdministration (FDA21 CFR 178
4、.3297) compliance of carbonblacks used for indirect food contact applications.1.2 UnitsThe values stated in SI units are to be regardedas the standard. No other units of measurement are included inthis standard.1.3 This standard does not purport to address all of thesafety concerns, if any, associat
5、ed with its use. It is theresponsibility of the user of this standard to establish appro-priate safety, health, and environmental practices and deter-mine the applicability of regulatory limitations prior to use.1.4 This international standard was developed in accor-dance with internationally recogn
6、ized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade (TBT) Committee.2. Referenced Documents2.1 Federal Standard:221 CFR 178.3297 Indi
7、rect Food Additives: Adjuvants, Pro-ductions Aids, and Sanitizers, Colorants for Polymers3. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 polycyclic aromatic hydrocarbon, PAH, norganiccompound(s) that consist of chemical structures of alternatingsingle and double bonds of a rin
8、g like nature (for example,benzene), with no heteroatom or other substituents; frequentlythe rings are fused to make larger chemical structures.3.1.1.1 DiscussionPAH naturally occur in oil, coal, and tardeposits; are produced by the incomplete combustion ofhydrocarbons; and occur in many other produ
9、cts and processes.3.1.2 EU-8 PAH compound list, na list of eight polycyclicaromatic hydrocarbons that are specified by the CommissionRegulation (EU) 1272/2013 (December 6, 2013)3amendingAnnex XVII to Regulation (EC) 1907/2006 of the EuropeanParliament and of the Council on the Registration, Evaluati
10、on,Authorisation and Restriction of Chemicals (REACH) asregards polycyclic aromatic hydrocarbons (2013) OJ L328/69.3.1.2.1 DiscussionRegulation (EU) No. 1272/2013 setsPAH concentration limits on finished products specified bytheir application. The regulation does not refer directly tocarbon black, t
11、hough in many instances and for formulationpurposes there is a need to know the quantitative, extractablePAH content present in carbon black that will become part ofthe finished product. In addition, no specific test method hasbeen defined by the regulation for testing finished products orraw materi
12、als used in the finished products.4. Summary of Test Method4.1 A portion of carbon black is Soxhlet-extracted withtoluene for 48 h. The extract is concentrated and subsequentlyanalyzed for specific PAH compounds by gas chromatographywith mass spectrometry (GC/MS). Each PAH compound isquantified indi
13、vidually using internal and external standards.5. Significance and Use5.1 This test procedure is used to determine the individualconcentrations of the PAH compounds in the EU-8 list ex-tracted from carbon black by the means of a Soxhlet extractionapparatus with toluene.1This test method is under the
14、 jurisdiction of ASTM Committee D24 on CarbonBlack and is the direct responsibility of Subcommittee D24.66 on Environment,Health, and Safety.Current edition approved Oct. 1, 2017. Published November 2017. DOI:10.1520/D8143-17.2Available from U.S. Government Printing Office, Superintendent ofDocument
15、s, 732 N. Capitol St., NW, Washington, DC 20401-0001, http:/www.access.gpo.gov.3Commission Regulation (EU) No 1272/2013 of 6 December 2013.Available athttp:/eur-lex.europa.eu/eli/reg/2013/1272/oj.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. Unit
16、ed StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers
17、 to Trade (TBT) Committee.16. Apparatus6.1 Soxhlet Extractor with Reflux Condenser, 50 or 100 cm3capacity.6.2 Extraction Thimbles, glass or cellulose, approximately50 to 70 cm3capacity. For instance, glass extraction thimble of35 mm diameter by 90 mm height with course porosity (70 to100 m similar t
18、o Ace Glass Size C, Porosity B, Code-14).6.3 Heating Mantle, compatible with boiling flask describedin 6.4.6.4 Boiling Flasks for Soxhlet, for example, 250 cm3.6.5 Glass Beads, approximately 180 to 250 m (60/80mesh) if glass thimbles are used. Need to be very clean ortoluene extracted.6.6 Glass Boil
19、ing Beads, approximately 3 mm.6.7 Glass Wool, need to be very clean or toluene extracted.6.8 Rotary Evaporator, with temperature-controlled waterbath, automatic pressure regulation, and solvent-proof mem-brane vacuum pump. Other evaporators may be used if theyproduce acceptable results.6.9 Nitrogen
20、Blow-Down Apparatus, equipped with a con-trolled water bath and nitrogen pressure control.6.10 Pear-Shaped Flasks for Rotary Evaporator, forexample, 25, 50, and 100 cm3.6.11 GC/MS, with autosampler.6.11.1 Mass Spectrometer (MS), with electron impact capa-bility and Selected Ion Monitoring (SIM) mode
21、.6.11.2 GC Capillary Column, usually a nonpolar GC col-umn composed of 5 % diphenyl/95 % dimethyl polysiloxanecoating is used for PAH analysis. Other similar column phasesmay be used if they provide acceptable peak resolutions.6.11.3 Deactivated Straight Borosilicate Liner with SmallPiece of Deactiv
22、ated Glass WoolThis liner may be used aslong as peak resolution is satisfactory.6.11.4 Alternative liner is a split/splitless nondeactivatedliner with glass wool (4 mm internal diameter, straight liner).This shall be deactivated with a silanizing agent before use.Another alternative is a split/split
23、less liner with fluorocarbonliner seals. Such a liner will already contain conditionedsilanized glass wool. Other liners can be used if they produceacceptable results.6.11.5 Gold-Plated Seal, for GC injector port or similarnonreactive seal.6.11.6 GC/MS Amber Autosampler Vials, with polytetra-fluoroe
24、thylene (PTFE)-coated caps.6.12 Adjustable Micropipettes, for example 1000, 200, and20 L, or similar analytical-grade volume measuring equip-ment.6.13 Microliter Syringes of Different Volumes, for example,10 and 100 L.6.14 Volumetric Flasks, for example 10 and 100 cm3.6.15 Analytical Balance, with a
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTM D8143 17 Standard Test Method for Determination of the EU List PAH Compounds in Carbon Black

链接地址:http://www.mydoc123.com/p-287336.html