ASTM B229-12(2017) Standard Specification for Concentric-Lay-Stranded Copper and Copper-Clad Steel Composite Conductors.pdf
《ASTM B229-12(2017) Standard Specification for Concentric-Lay-Stranded Copper and Copper-Clad Steel Composite Conductors.pdf》由会员分享,可在线阅读,更多相关《ASTM B229-12(2017) Standard Specification for Concentric-Lay-Stranded Copper and Copper-Clad Steel Composite Conductors.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: B229 12 (Reapproved 2017)Standard Specification forConcentric-Lay-Stranded Copper and Copper-Clad SteelComposite Conductors1This standard is issued under the fixed designation B229; the number immediately following the designation indicates the year oforiginal adoption or, in the case o
2、f revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers concentric-lay-stranded con-ductors made from uncoated hard-drawn ro
3、und copper wires incombination with hard-drawn round copper-clad steel wires forgeneral use as overhead electrical conductors.1.2 For the purpose of this specification, conductors areclassified under the following type designations (see Fig. 1):Type A Type GType C Type JType D Type KType E Type NTyp
4、e EK Type PType F Type V1.3 The SI values for density are regarded as the standard.For all other properties the inch-pound values are to beregarded as standard and the SI units may be approximate.1.4 This international standard was developed in accor-dance with internationally recognized principles
5、on standard-ization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2B1 Specification for Hard-Drawn Copper
6、 WireB227 Specification for Hard-Drawn Copper-Clad Steel WireB354 Terminology Relating to Uninsulated Metallic Electri-cal ConductorsE29 Practice for Using Significant Digits in Test Data toDetermine Conformance with Specifications2.2 ANSI Standard:C42 Definitions of Electrical Terms32.3 National In
7、stitute of Standards and Technology:NBS Handbook 100Copper Wire Tables43. Ordering Information3.1 Orders for material under this specification shall includethe following information:3.1.1 Quantity of each size and type;3.1.2 Conductor size: hard-drawn copper equivalent incircular-mil area or AWG (Se
8、ction 7 and Table 1);3.1.3 Type (see 1.2, Fig. 1, and Table 1);3.1.4 Direction of lay of outer layer, if other than left-hand(see 6.3);3.1.5 When physical tests shall be made (see section 8.2);3.1.6 Package size (see 14.1);3.1.7 Special package marking, if required (Section 15);3.1.8 Lagging, if req
9、uired (see 14.2); and3.1.9 Place of inspection (Section 13).4. Material for Wires4.1 The purchaser shall designate the size and type ofconductor to be furnished. The position of the hard-drawncopper wires and the copper-clad steel wires in the conductorcross section shall be as shown in Fig. 1.4.2 B
10、efore stranding, the wire used shall meet the require-ments of Specifications B1 and B227 that are applicable to itstype.5. Joints5.1 CopperWelds and brazes may be made in copper rodsor in copper wires prior to final drawing. Joints may not bemade in the finished copper wires composing concentric-la
11、y-stranded composite conductors containing a total of sevenwires or less. In other conductors, welds and brazes may bemade in the finished individual copper wires composing the1This specification is under the jurisdiction of ASTM Committee B01 onElectrical Conductors and is the direct responsibility
12、 of Subcommittee B01.06 onBi-Metallic Conductors.Current edition approved April 1, 2017. Published April 2017. Originallyapproved in 1948. Last previous edition approved in 2012 as B229 12. DOI:10.1520/B0229-12R17.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM C
13、ustomer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.4Available from Nati
14、onal Institute of Standards and Technology (NIST), 100Bureau Dr., Stop 1070, Gaithersburg, MD 20899-1070, http:/www.nist.gov.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with i
15、nternationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.1conductor, but shall be not closer than 50 f
16、t (15 m) to any otherjoint in the same layer in the conductor.5.2 Copper-Clad SteelJoints or splices may be made inthe finished individual copper-clad steel wires composingconcentric-lay-stranded conductors, provided that such jointsor splices have a protection equivalent to that of the wire itselfa
17、nd that they do not decrease the strength of the finishedstranded conductor below the minimum breaking strengthshown in Table 1. Such joints or splices shall be not closer than50 ft (15 m) to any other joint in the same layer in theconductor (Explanatory Note 1).6. Lay6.1 For Types A, C, and D condu
18、ctors, the preferred lay isapproximately 16.5 times the outside diameter of the com-pleted conductor, but shall be not less than 13 nor more than 20times this diameter.6.2 For all other types, the preferred lay of a layer of wiresis 13.5 times the outside diameter of that layer, but shall be notless
19、 than 10 nor more than 16 times this diameter.6.3 The direction of lay of the outer layer shall be left-handunless the direction of lay is specified otherwise by thepurchaser.6.4 The direction of lay shall be reversed in successivelayers.6.5 All wires in the conductor shall lie naturally in their tr
20、uepositions in the completed conductor. They shall tend to remainin position when the conductor is cut at any point and shallpermit restranding by hand after being forcibly unraveled at theend of the conductor.7. Construction7.1 The numbers and diameters of wires in the various typesof concentric-la
21、y-stranded composite conductors shall conformto the requirements prescribed in Table 1 (Explanatory Note 2).8. Physical and Electrical Tests8.1 Tests for the physical and electrical properties of wirescomposing concentric-lay-stranded composite conductors shallbe made before but not after stranding.
22、8.2 At the option of the purchaser or his representative,tension and elongation tests on wires before stranding may bewaived, and the completed conductor may be tested as a unit.The breaking strength of the conductors so tested shall be notless than the rated strength values shown in Table 2. The fr
23、eelength between grips of the test specimen shall be not less than24 in. (0.61 m), and care shall be taken to ensure that the wiresin the conductor are evenly gripped during the test (Explana-tory Note 3).9. Density9.1 For the purpose of calculating weights, cross sections,and so forth, the density
24、of the copper shall be taken as 8.89g/cm3at 20C (Explanatory Note 4 and Table 2).9.2 The density of both types of copper-clad-steel wire shallbe taken as stated in Table 2.10. Mass and Resistance10.1 The mass and electrical resistance of a unit length ofstranded conductor are a function of the lengt
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTM B229 12 2017 Standard Specification for Concentric Lay Stranded Copper and Clad Steel Composite Conductors

链接地址:http://www.mydoc123.com/p-286705.html