JASO C712-1982 英文版 动力转向泵性能台架试验规程.pdf
《JASO C712-1982 英文版 动力转向泵性能台架试验规程.pdf》由会员分享,可在线阅读,更多相关《JASO C712-1982 英文版 动力转向泵性能台架试验规程.pdf(13页珍藏版)》请在麦多课文档分享上搜索。
1、日本汽车标准_JASO C712-1982 英文版 动力转向泵性能台架试验规程_JAPANESE AUTOMOBILE STANDARD JAS0 C 7 12-82 Bench Test Procedure for the Performance of Power Steering Pump 1. Scope This standard covers the bench test procedure for the performance of oil pumps for automobile power steering systems. Remark: In this standard,
2、 units and numerical values given in are based on the International System of Units (SI), and are given for reference. 2. Purpose lhe purpose of this standard is to establish a general bench test procedure for the performance of pumps. 3. Definitions For the purposes of this standard, the following
3、definitions are applied. Preferred number of revolutions Shall refer to the preferred number of revolutions per minute of a pump used on a vehicle. No load pressure Shall refer to the power steering system pressure, generally below 5kgf/cm2 0.5MPa1, assumed to indicate in its neutral position. Relie
4、f pressure Shall refer to the preset pressure set on a relief valve which allows the working fluid to escape when the system pressure exceeds the preset value. Input torque Shall refer to the torque required to drive the pump. 4. Kinds of Test The following kinds of test are specified in this standa
5、rd. Test on the effect of the number of revolutions on delivery flow (N-Q characteristic test) Test on the effect of delivery pressure on delivery flow (P-Q characteristic test) Relief pressure test Input torque test Noise test Leak test 5. General Test Conditions The following test conditions shall
6、 be used unless otherwise specified. Ambient temperature shall be based on JIS 2 8703 (Standard Conditions for Testing) Grade 4 or 20 1 15OC. Working fluid Shall be as agreed between the parties concerned. Temperature of working fluid Shall be 55OC f Air bleeding Prior to any test, the pump and the
7、testing system shall be bled sufficiently. Break-in Prior to any test, a pump to be tested shall be subjected to a proper amount of break-in. Measuring instrument A suitable measuring instrument or instruments shall be used for the test concerned. Particularly converting delivery flow into an electr
8、ical signal, the measuring instrument shall be calibrated before a test is performed. Operation When an X-Y recorder is used, the number of revolutions and the pressure shall be changed at a rate with which the X-Y recorder can follow. 5 c. 6. Test Pump A pump to be tested shall either be re-adjuste
9、d under official supervision, removed wholly from the vehicle, or reinstalled. 7. Testing Method 7.1 Test on Effect of Number of Revolutions on Delivery Flow (N-0 characteristic Test) This test shall be used to measure the delivery flow of a pump at different numbers of revolutions per minute while
10、holding delivery pressure constant. (1) Instrumentation Shown in Fig. 1. Applicable Standard: JIS C 1502 - 1977 Sound Level Meters Reference Standard: JIS 2 8703 - 1976 Standard Conditions for Testing JIS B 0118 - 1970 Glossary of Terms for Oil Hydraulics JIS B 0125 - 1972 Graphical Symbols for Flui
11、d Power Diagrams JASO C 71 1 - 79 Bench Test Procedure for the Performance of Integral Type, Power Steering JAS0 C 7 12-82 Fig. 1 Block Diagram for Measuring N-O Characteristic X-Y recorder / /I I8 I8 /I ,I Pressure gauge I 1 Variable-speed motor T- w Tachometer / W Stop valve or balance-type relief
12、 valve pump to be tested (jm Oil tank Thermometer (2) Test Conditions Number of revolutions Shall be within the range of preferred revolutions. Delivery pressure Shall be no-load pressure unless otherwise specified. Remark: Where other than no-load pressure values are required for testing, 30kgf/cmZ
13、 3.0MPa, 50kgf/cma 5.OMPa are recommended. (3) Test Procedure A test procedure shall consist of (I), varying the number of revolutions gradually from the lowest to the highest value while a constant delivery pressure is maintained by means of controling stop valve or a balance-type relief valve, and
14、 (21, taking a successive record of the delivery flow according to the changes of rpms. The measurements shall be recorded on the X-Y recorder with graph paper shown in Attached Table 2. Test results and comments shall be filled appropriately in a form shown in Attached Table 1. (4) Recording 7.2 Te
15、st on Effect of Delivery Pressure on Delivery This test shall be used to measure the delivery flow of a pump at different delivery pressures while holding pump speed constant. Flow (P-O Curve Test) (1) Instrumentation Shown in Fig. 2. 2 JAS0 C 712-82 Fig. 2 Block Diagram for Measuring P-Q Characteri
16、stic X-Y recorder /I / , / / I, Pressure pickup Variable-speed motor or with , speed change gear ! / Stop valve or balance-type relief valve Tachometer pump to be tested &-i! Oil tank Thermometer Test Conditions 0 Temperature of working fluid Shall be 55 * 5OC or 80 I5OC. Delivery pressure Shall be
17、between the no-load and pump relief pressufes. Number of revolutions Shall be 600rpm and values agreed upon between the parties concerned. Test Procedure A test procedure shall consist of (1 ), setting the pump at specified values of rpm and no-load pressure, (2), gradually throttling the stop valve
18、 or the balance-type relief valve while controling the speed change gear in order to maintain the rpm, and (31, taking a successive record of delivery flow according to the changes of delivery pressures. Fig. 3 Block Diagram for Mearuing Relief Pressure (4) Recording The measurements shall be record
19、ed on the X-Y recorder with graph paper shown in Attached Table 3. I Test results and comments shall be filled appropriately in a form shown in Attached Table 1. 7.3 Relief Pressure Test This test shall be used to measure the relief pressure of a pump, and may be conducted together with a test speci
20、fied in 7.2. (1) Instrumentation Shown in Fig. 3. Tachometer Pressure gauge n Variable-speed motor or with speed change gear Stop valve or balance-type relief valve T- o 2, pump to be tested oil tank Thermometer 3 JAS0 C 712-82 L (2) Test Conditions Number of revolutions: Shall be 600rpm or values a
21、greed upon between the parties con- cerned. Relief pressure shall be read enough after the stop valve or the balance-type relief valve has been tightly closed. The relief pressure shall not be maintained for more than 5 seconds. The Results and comments shall be filled in a form as shown in Attached
22、 Table 1. (3) Test Procedure (4) Recording 7.4 Input Torque Test This test shall be used to measure the input torque of a pump at different values of pump rpm and delivery pressure. (1) Instrumentation An example of testing equipments is shown schematically in Fig. 4, in which a torque pickup is set
23、 between the pump and the variable-speed motor. (2) Test Conditions 0 Number of revolutions Shall be within the range of preferred rpms. Delivery pressure Shall be no-load pressure and values agreed upon between the parties concerned. (3) Test Procedure The pump speed shall be varied gradually from
24、the lowest value to the highest within the preferred rpm range, and a successive record of input torque shall be taken as it varies accord- ing to the changes of rpms. The measurements shall be recorded on the X-Y recorder with graph paper shown in Attached Table 4. Results and comments shall be fil
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- JASO C712 1982 英文 动力 转向 性能 台架 试验 规程