1、Designation: F3150 15F3150 18Standard Specification forHEPA Filtration System Performance of Residential andCommercial Vacuum Cleaners1This standard is issued under the fixed designation F3150; the number immediately following the designation indicates the year oforiginal adoption or, in the case of
2、 revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification defines industry acceptable test methods and approaches for evaluating resid
3、ential and commercialvacuum cleaner filtration systems to HEPA filtration performance levels.1.2 This specification defines the minimum filtration efficiency requirements for achieving HEPA performance for filtrationsystems of residential and commercial vacuum cleaners.1.3 This specification applies
4、 only to residential and commercial vacuum cleaning products that are used in non-criticalapplications. Non-critical applications refers to applications not requiring the removal of hazardous dust as defined per IEC60335-2-69.1.4 This standard does not purport to address all of the safety concerns,
5、if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety safety, health, and healthenvironmental practices and determine theapplicability of regulatory limitations prior to use.1.5 This international standard was developed in accordance wi
6、th internationally recognized principles on standardizationestablished in the Decision on Principles for the Development of International Standards, Guides and Recommendations issuedby the World Trade Organization Technical Barriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:
7、2F1977 Test Method for Determining Initial, Fractional, Filtration Efficiency of a Vacuum Cleaner SystemF2608 Test Method for Determining the Change in Room Air Particulate Counts as a Result of the Vacuum Cleaning ProcessF395 Terminology Relating to Vacuum Cleaners2.2 European Standards:3EN 18225 H
8、igh Efficiency Air Filters (EPA, HEPA, and ULPA) Part 5: Determining the Efficiency of Filter Elements2.3 IEST Standards:4IEST-RP-CC0001.5IEST-RP-CC001 HEPA and ULPA filtersIEST-RP-CC0007.2IEST-RP-CC007 Testing ULPA FiltersIEST-RP-CC0034IEST-RP-CC034 HEPA and ULPA Filter Leak Tests2.4 IEC Standard:5
9、IEC 60335269, Edition 4.05.0 Particular Requirements for Wet and Dry Vacuum Cleaners for Commercial use, Clause 3.1042.5 ISO Standard:6ISO 29463-5 High-efficiency filters and filter media for removing particles in air Part 5: Test method for filter elements1 This specification is under the jurisdict
10、ion of ASTM Committee F11 on Vacuum Cleaners and is the direct responsibility of Subcommittee F11.23 on Filtration.Current edition approved Nov. 1, 2015Oct. 1, 2018. Published November 2015October 2018. Originally approved in 2015. Last previous edition approved in 2015 asF3150 15. DOI: 10.1520/F315
11、0-15.10.1520/F3150-18.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.3 Available from British Standards Inst
12、itution (BSI), 389 Chiswick High Rd., London W4 4AL, U.K., http:/.4 Available from Institute of Environmental Sciences and Technology (IEST), Arlington Place One, 2340 S. Arlington Heights Rd., Suite 100, Arlington Heights, IL60005-4516, http:/www.iest.org.5 Available from International Electrotechn
13、ical Commission (IEC), 3, rue de Varemb, P.O. Box 131, CH-1211 Geneva 20, Switzerland, http:/www.iec.ch.6 Available from International Organization for Standardization (ISO), ISO Central Secretariat, BIBC II, Chemin de Blandonnet 8, CP 401, 1214 Vernier, Geneva,Switzerland, http:/www.iso.org.This do
14、cument is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions a
15、s appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States13. Terminology3.1 Definitions:3.1.1 commercial vacuum c
16、leanera vacuum cleaner suitable for the heavy duty and sometimes continuous cleaning tasksencountered in establishments such as hotels, motels, office buildings, churches, clubs, etc.3.1.2 filtration systemrefers to the filtration efficiency performance of the vacuum cleaners dust capturing system m
17、inus anymotor emissions. Motor emissions are not included in determining filtration system efficiency performance since motor emissionsare generated independently of the cleaning process and are not a part of the dust and debris being removed from the floor surface.Motor emissions are addressed unde
18、r Test Method F2608.3.1.3 HEPA (High Effciency Particulate Air)refers to a level of filtration performance in terms of particulate efficiencies.3.1.4 residential vacuum cleanera vacuum cleaner suitable for the normal cleaning tasks encountered in residences and familyhouseholds, in contrast to a com
19、mercial vacuum cleaner.4. Sampling4.1 Aminimum of three units of the same model vacuum cleaner selected at random in accordance with good statistical practiceshall constitute the population sample.Filter Element:4.1.1 Where the referenced filter element test methods do not provide guidance for rando
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF31502018STANDARDSPECIFICATIONFORHEPAFILTRATIONSYSTEMPERFORMANCEOFRESIDENTIALANDCOMMERCIALVACUUMCLEANERSPDF

链接地址:http://www.mydoc123.com/p-1243984.html