1、Designation: E2112 18bE2112 19Standard Practice forInstallation of Exterior Windows, Doors and Skylights1This standard is issued under the fixed designation E2112; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last re
2、vision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.INTRODUCTIONThis document is intended to provide technical guidance to organizations that are developingtraining programs for installers
3、of fenestration units in low-rise residential and light commercialstructures. The majority of fenestration units selected for installation in these types of structures arecertified as meeting specified performance characteristics in standardized laboratory testing. Experi-ence indicates, however, th
4、at the performance of fenestration installations is frequently significantlyinferior to the performance of the manufactured units in laboratory testing. Installation of fenestrationunits can significantly influence in-service performance.The requirements promulgated in this practice have, by consens
5、us, (of individuals with specializedknowledge concerning installation of fenestration units) been identified as necessary to ensure thatas-installed performance is roughly equivalent to performance in laboratory testing. The task groupresponsible for development of this practice recognizes that buil
6、ding owners sometimes, accept asadequate, in-service performance of fenestration installations that are significantly inferior those of theunits in laboratory testing. This practice is not intended for use in such circumstances, where ownerexpectations are modest. The intent of this practice is to p
7、rovide guidance to those concerned withensuring that as-installed performance is comparable to the capabilities of the units installed for a solidmajority of installations.A particularly noticeable behavior that indicates deficiencies in installation is rainwater leakage.Rainwater leakage has been t
8、he leading reason for dissatisfaction of building owners with performanceof fenestration installations. For this reason, this practice places greater emphasis on preventing orlimiting rainwater leakage than on any other single performance characteristic.This practice emphasizes that the water-sheddi
9、ng surfaces of fenestration units must be adequatelyintegrated with adjacent water-shedding surfaces of the building envelope. It does not, however,attempt to promulgate requirements for water-shedding surfaces of building envelopes other thanthose interfacing with fenestration units. The standard a
10、ssumes that the basic design of the buildingswater-shedding system is adequate, that is, that either (1) there is a high probability that the outermostbuilding surface will dependably prevent all water entry, or (2) the building envelope incorporates aneffective concealed barrier that will dependabl
11、y prevent further intrusion of incidental water thatbreaches the outermost surface. The practice further assumes that fenestration units can be dependablysealed to, and integrated with, at least one of these surfaces. If the basic design of the buildingswater-shedding system is inadequate, or does n
12、ot allow for reliable integration of fenestration unitsinto it, competent installation of the units is unlikely to nullify these deficiencies.1. Scope1.1 This practice covers the installation of fenestration products in new and existing construction. For the purpose of thispractice, fenestration pro
13、ducts shall be limited to windows, sliding patio-type doors, swinging patio type doors, and skylights, asused primarily in residential and light commercial buildings.1.2 This practice assumes that the installer possesses basic woodworking skills and an understanding of wall and roofconstruction, she
14、et metal work, and joint sealant practices.1 This practice is under the jurisdiction of ASTM Committee E06 on Performance of Buildings and is the direct responsibility of Subcommittee E06.51 on Performanceof Windows, Doors, Skylights and Curtain Walls.Current edition approved Nov. 15, 2018Jan. 1, 20
15、19. Published December 2018February 2019. Originally approved in 2001. Last previous edition approved in 2018 asE211218a.18b. DOI: 10.1520/E211218B.10.1520/E211219.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have be
16、en made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official documen
17、t.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States11.3 This practice attempts to instruct and familiarize the installer with the concepts of both Barrier Systems andMembrane/Drainage Systems, in order to ensure the continuity of the bu
18、ilding envelope. This practice attempts to educate theinstaller, builder, architect, and other users in the identification and understanding of the water shedding system of the buildingenvelope.1.4 This practice covers the installation process from pre-installation procedures through post-installati
19、on procedures, for singleunits or factory-mulled multiple units in a single opening. It does not cover the fabrication or assembly of multiple units, whethersuch fabrication takes place in a factory or at the intended installation site. The installer should check with the manufacturer offactory-asse
20、mbled units for instructions for anchoring. When using field-mulled units, follow manufacturers recommendationsand make certain that they meet applicable codes. This practice does not cover the selection of appropriate fenestration productsfor a given application, nor the selection of other products
21、 or systems for use in the installation.1.5 This practice provides minimum requirements that will help to accomplish the installation of fenestration products in aneffective manner. Actual conditions in buildings vary greatly and, in some cases, substantial additional precautions may berequired. In
22、the event that the manufacturers installation instructions provided with the product conflict with requirements of thispractice, the manufacturers instructions shall prevail. This practice is not intended to limit or exclude other new procedures thatmay refine or further improve the effectiveness of
23、 fenestration installation.1.5.1 This practice is intended to be used for background information in order to develop training manuals and trainingprograms. Further, this practice attempts to consolidate and unify the various steps of construction, tying together the various tradesinvolved with the c
24、ontinuity between fenestration products and the building envelope.1.6 The text of this practice references notes and footnotes that provide explanatory material. These notes and footnotes(excluding those in tables and figures) shall not be considered as requirements of this practice.1.7 This standar
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME21122019STANDARDPRACTICEFORINSTALLATIONOFEXTERIORWINDOWSDOORSANDSKYLIGHTSPDF

链接地址:http://www.mydoc123.com/p-1243859.html