1、Designation: D7318 18Standard Test Method forExistent Inorganic Sulfate in Ethanol by PotentiometricTitration1This standard is issued under the fixed designation D7318; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of la
2、st revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method covers a potentiometric titration pro-cedure for determining the existent inorganic sulfate content of
3、hydrous, anhydrous ethanol, and anhydrous denatured ethanol,which is added as a blending agent with spark ignition fuels. Itis intended for the analysis of denatured ethanol samplescontaining between 1.0 mg kg to 20 mg kg existent inorganicsulfate.1.2 The values stated in SI units are to be regarded
4、 asstandard. No other units of measurement are included in thisstandard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety, health, and environmental practices
5、 and deter-mine the applicability of regulatory limitations prior to use.Material Safety Data Sheets are available for reagents andmaterials. Review them for hazards prior to usage.1.4 This international standard was developed in accor-dance with internationally recognized principles on standard-iza
6、tion established in the Decision on Principles for theDevelopment of International Standards, Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2D1193 Specification for Reagent WaterD4052 Test Metho
7、d for Density, Relative Density, and APIGravity of Liquids by Digital Density MeterD4057 Practice for Manual Sampling of Petroleum andPetroleum ProductsD4177 Practice for Automatic Sampling of Petroleum andPetroleum ProductsD6299 Practice for Applying Statistical Quality Assuranceand Control Chartin
8、g Techniques to Evaluate AnalyticalMeasurement System Performance3. Terminology3.1 Definitions:3.1.1 existent inorganic sulfate, ninorganic sulfate speciesactually present in the sample at the time of analysis with nooxidation treatment.3.1.1.1 DiscussionSpecifically in this test method, inor-ganic
9、sulfate is present as sulfate in ethanol.3.1.2 inorganic sulfate, nsulfate (SO42) species presentas sulfuric acid, ionic salts of this acid, or mixtures of these.4. Summary of Test Method4.1 An ethanol sample containing inorganic sulfate istitrated in ethanolic medium with a standard lead nitratesol
10、ution. Lead sulfate precipitate is formed during the titration.Perchloric acid is added to remove possible interference fromcarbonate. The endpoint is signaled by an increase in lead ionactivity, as measured by a lead-selective electrode.5. Significance and Use5.1 Ethanol is used as a blending agent
11、 added to gasoline.Sulfates are indicated in filter plugging deposits and fuelinjector deposits. When fuel ethanol is burned, sulfates maycontribute to sulfuric acid emissions. Ethanol acceptability foruse depends on the sulfate content. Sulfate content, as mea-sured by this test method, can be used
12、 as one measure ofdetermination of the acceptability of ethanol for automotivespark-ignition engine fuel use.6. Apparatus6.1 Potentiometric Titration AssemblyA titration assem-bly consisting of an automatic titrator fitted with a leadion-selective electrode, a double-junction reference electrode,bur
13、et, and stirring is used. Stirring may be accomplished bymeans of magnetic or propeller type stirrer mechanisms. Theburet size should ideally be 10 mL or 20 mL.1This test method is under the jurisdiction of ASTM Committee D02 onPetroleum Products, Liquid Fuels, and Lubricants and is the direct respo
14、nsibility ofSubcommittee D02.03 on Elemental Analysis.Current edition approved Oct. 1, 2018. Published October 2018. Originallyapproved in 2007. Last previous edition approved in 2013 as D7318 13. DOI:10.1520/D7318-18.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact AS
15、TM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshoh
16、ocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by the World Trade Organ
17、ization Technical Barriers to Trade (TBT) Committee.16.2 Reference ElectrodeA double junction reference elec-trode with the inner electrode composed of silver/silver chlo-ride with a potassium chloride solution as internal electrolyte.The external solution is composed of 1 M lithium chloride inethan
18、ol. This configuration is used to prevent silver ion, a leadelectrode poison, from leaching into the analyte solution duringtitration. Preferred electrolytes for use in double junctionelectrodes may vary with the manufacturer; use the manufac-turers recommended electrolytes for the application. Othe
19、rtypes of reference electrodes may be considered with somecaveats (for example, single junction, combination, or glassycarbon), but the data presented in this test method weregenerated using exclusively a double junction electrode, whichis the best choice for this determination.6.3 Lead ElectrodeA l
20、ead sulfide-based crystalline sensortype lead ion selective electrode (ISE) is used.6.4 Drying OvenA drying oven for drying sodium sulfateat 110 C is required.6.5 Pipets or Volumetric Transferring DevicesClass Aglass pipets or their equivalent.6.6 Polishing MaterialLead sulfide based crystalline sen
21、-sor electrodes require polishing to remove oxidation products.These materials are supplied with the electrode from themanufacturer.6.7 pH Test StripsTest strips in the range of pH 1 to pH 7.6.8 Titration VesselsStandard glass beakers or titrationvessels supplied with titration equipment.7. Reagents
22、 and Materials7.1 Lead NitrateReagent grade, 99 % minimum purity.(WarningPoison, harmful by inhalation and if ingested.Avoid contact with the skin.) Dispose of this material inaccordance with accepted local requirements.7.2 Sodium SulfateAnhydrous, reagent grade, 99 % mini-mum purity. (WarningDo not
23、 ingest. Avoid unnecessaryexposure.)7.3 Perchloric Acid 70 %A.C.S. reagent grade, minimumpurity with sulfate concentration 0.001 % (m/M). Dispose ofthis material in accordance with accepted local requirements. Itmust contain no measurable sulfate. (WarningCorrosive;keep away from skin and eyes. Perc
24、hloric acid is a strongoxidizer.)7.4 EthanolDenatured with methanol, formula 3A or his-tological grade ethanol, anhydrous, denatured with ethylacetate, methyl isobutyl ketone and hydrocarbon naphtha. Itmust be free of any measurable sulfate. (WarningFlammable, toxic, may be harmful or fatal if inges
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD73182018STANDARDTESTMETHODFOREXISTENTINORGANICSULFATEINETHANOLBYPOTENTIOMETRICTITRATIONPDF

链接地址:http://www.mydoc123.com/p-1243734.html