ASTM B539-2018 Standard Test Methods for Measuring Resistance of Electrical Connections (Static Contacts).pdf
《ASTM B539-2018 Standard Test Methods for Measuring Resistance of Electrical Connections (Static Contacts).pdf》由会员分享,可在线阅读,更多相关《ASTM B539-2018 Standard Test Methods for Measuring Resistance of Electrical Connections (Static Contacts).pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: B539 18Standard Test Methods forMeasuring Resistance of Electrical Connections (StaticContacts)1This standard is issued under the fixed designation B539; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last
2、 revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 These test methods cover equipment and techniques formeasuring the resistance of static electrical connections such aswire
3、 terminations or splices, friction connectors, solderedjoints, and wrapped-wire connections.1.2 Measurements under two distinct levels of electricalloading are described. These levels are: (1) dry circuit, (2) andrated current. One or both of these levels of loading may berequired in specific cases.
4、1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to become familiarwith all hazards including those identified in the appropriateSafety Data Sheet (SDS) for this product/material as provided
5、by the manufacturer, to establish appropriate safety, health,and environmental practices, and determine the applicabilityof regulatory limitations prior to use.1.4 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in t
6、he Decision on Principles for theDevelopment of International Standards, Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2B542 Terminology Relating to Electrical Contacts and TheirUseE122 Practice
7、 for Calculating Sample Size to Estimate, WithSpecified Precision, the Average for a Characteristic of aLot or Process3. Terminology3.1 Definitions:3.1.1 See Terminology B542 for definitions of contactresistance, film resistance, and constriction resistance.3.1.2 bulk resistance, nthe resistance a c
8、ontact assemblywould have if it were solid metal of an identical geometry sothat the nominal contact area offered zero resistance. Whenmeasuring contact resistance one attempts to include as littlebulk resistance as possible in the measurement, by placingmeasuring probes as close to the contact inte
9、rface as practical.3.1.3 connection resistance, nthe resistance from the ter-mination point on one end of a device containing staticcontacts, through the contacts to the termination point on theother end of the device. The termination point is the location ona terminal of a device where a wire or pr
10、inted circuit pathelectrically connects to the terminal. This resistance is thevalue of resistance displayed by the device in a circuitapplication.3.1.3.1 DiscussionThe term contact resistance is oftenused in commercial literature to indicate the connection resis-tance displayed by the device in a s
11、tandard application. In themore rigorous usage of contact resistance, the connectionresistance is the sum of the contact resistance plus the bulkresistance of leads within the device that go to the staticcontacts from the point that the leads are connected to theexternal circuitry. Measurement of co
12、ntact resistance indepen-dent of all bulk resistance is very difficult for most commercialdevices.3.1.4 dry circuit, na circuit in which the open-circuitvoltage is less than or equal to 20 mV. Current is usually lowin a dry circuit, but a low-current circuit is not necessarily adry circuit. When the
13、 applied voltage (open-circuit voltage)istoo low to cause any physical changes in the contact junction,such as break-down of thin insulating films or softening ofcontact asperities, the circuit is said to be a dry circuit.3.1.5 open-circuit voltage, nthe steady-state voltagewhich would appear across
14、 the contacts if they were opened.3.1.6 static contacts, nelectric junctions designed forinfrequent separation and connection, and intended to performtheir function only when contacting members are stationaryrelative to each other. This definition includes crimped,1These test methods are under the j
15、urisdiction of ASTM Committee B02 onNonferrous Metals and Alloys and are the direct responsibility of SubcommitteeB02.11 on Electrical Contact Test Methods.Current edition approved Nov. 1, 2018. Published December 2018. Originallyapproved in 1970. Last previous edition approved in 2013 as B539 02 (2
16、013).DOI: 10.1520/B0539-18.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100
17、Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards, Guides and Rec
18、ommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.1welded, brazed, riveted, or soldered joints; friction connectionssuch as pin and socket connectors or taper pins, twisted-wiresplices; and connections made with screws, or bolts and nutsbetween electrica
19、l wiring and components. The definitionexcludes relay contacts, slip rings and commutators, andswitches and circuit breakers.3.2 Descriptions of Terms for Levels of Electrical Loading:3.2.1 dry circuit, nThis method provides for measurementof contact resistance under very low levels of electricalexc
20、itation, with applied voltages and currents selected to be toolow to cause breakdown of thin oxide films or other contami-nates in the contact interface or to cause formation of metallicbridges across the interface where none may otherwise exist.Dry circuit testing is intended to determine whether t
21、he testcontact will function properly in circuits of arbitrarily lowlevels of electrical excitation. Dry circuit testing proceduresshould be used when the possibility of films or contaminants inthe contact interface exists or when the test sample is ulti-mately intended for use in a low-level circui
22、t. This testing mustprecede other tests on the same samples at high levels ofelectrical loading.3.2.2 rated current, nThe rated current for a static contactdevice is determined or specified by the vendor or user of thedevice. The rated current may be large enough to causesignificant heating of the t
23、est samples. When rated currentmeasurements of contact resistance are required, using eitherac or dc test currents, the procedures outlined for temperaturestabilization in 9.5.3 must be followed.4. Summary of Test Methods4.1 The test methods described herein are characterized asfour-terminal resista
24、nce measuring techniques, wherein a mea-sured and controlled test current is introduced into the sampleusing two“ terminals” or connecting points, and two otherpoints are selected on the sample across which a voltage dropis measured. This voltage drop, divided by the test current, isthe effective ov
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMB5392018STANDARDTESTMETHODSFORMEASURINGRESISTANCEOFELECTRICALCONNECTIONSSTATICCONTACTSPDF

链接地址:http://www.mydoc123.com/p-1243414.html