UL SUBJECT 498B-2015 UL Outline for Investigation Receptacles with Integral Switching Means (Issue 2)《带有整体切换装置的插座的UL调查大纲 (议题2)》.pdf
《UL SUBJECT 498B-2015 UL Outline for Investigation Receptacles with Integral Switching Means (Issue 2)《带有整体切换装置的插座的UL调查大纲 (议题2)》.pdf》由会员分享,可在线阅读,更多相关《UL SUBJECT 498B-2015 UL Outline for Investigation Receptacles with Integral Switching Means (Issue 2)《带有整体切换装置的插座的UL调查大纲 (议题2)》.pdf(68页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULJUNE 26, 20151UL 498BOutline of Investigation for Receptacles with Integral Switching MeansIssue Number: 2June 26, 2015Summary of TopicsThis is the second issue of the Outline of Investigation fo
2、r Receptacleswith Integral Switching Means, UL 498B. This new issue now covers areceptacle with an integral switching means where a Class 2 signalingdevice such as a sensor, timer or energy-management equipment isconnected to the controlled receptacle by a Class 2 separable leadassembly.ULs Outlines
3、 of Investigation are copyrighted by UL. Neither a printed norelectronic copy of an Outline of Investigation should be altered in any way. All ofULs Outlines of Investigation and all copyrights, ownerships, and rights regardingthose Outlines of Investigation shall remain the sole and exclusive prope
4、rty of UL.COPYRIGHT 2015 UNDERWRITERS LABORATORIES INC.UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULJUNE 26, 2015UL 498B2No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION F
5、ROM ULCONTENTSINTRODUCTION1 Scope .62 Components 73 Units of Measurement 74 Undated References 85 Glossary 8CONSTRUCTION6 General 117 Configurations 118 Accessibility of Live Parts 119 Current-Carrying Parts .1310 Internal Wiring .1311 Internal Splices and Connections 1311.1 General .1311.2 Wire-wra
6、pped connections 1411.3 Wiring terminals and leads 1512 Separation of Circuits .1513 Insulating Material 1714 Printed-Wiring Boards 1715 Components .1815.1 Switching devices 1815.2 Capacitors .1815.3 Power-switching semiconductors .1915.4 Isolation devices .1916 Transformers 1916.1 General .1916.2 I
7、solation transformers .2017 Spacings 2118 Alternate Spacings Clearances and Creepage Distances 2319 Bonding of Internal Parts for Grounding .2420 Class 2 Circuits 2421 Class 2 Separable Lead Assembly 27PERFORMANCE22 General .2823 Temperature Test 2823.1 General .2823.2 Operation .2923.3 Temperature
8、measurements .3024 DC Offset Voltage Test .3125 Abnormal Operation Test .3125.1 Motor .3125.2 Component failure 3225.3 Abnormal switching test .3326 Limited Power Point Determination Test 3426.1 General .34JUNE 26, 2015 UL 498B 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTR
9、IBUTION WITHOUT PERMISSION FROM UL26.2 Option No. 1 .3426.3 Option No. 2 .3526.4 Component failure 3626.5 Overload test 3727 Isolation Tests 3827.1 General .3827.2 Pulse transformer burnout tests 3827.3 Optical isolator tests 4027.4 Component failure 4028 Power-Switching Semiconductors 4128.1 Genera
10、l .4128.2 Overload test 4228.3 Endurance 4329 Voltage Surge Test .4430 Power Supplies Short circuit 4631 Component Failure Test .4732 Electronic Component Evaluation 4733 Dielectric Voltage-Withstand Test .4833.1 General .4833.2 Primary circuits 4833.3 Isolated secondary circuits 4933.4 Transformers
11、 50MANUFACTURING AND PRODUCTION LINE TESTS34 DC Offset Voltage Test 51RATING35 Details .5135.1 Input 5135.2 Output 5135.3 Operational ambient temperature .52MARKINGS36 General 5237 Installation Instructions 53SUPPLEMENT SA - RECEPTACLES WITH INTEGRAL SWITCHING MEANS INTENDED FORENERGY MANAGEMENT AND
12、 BUILDING AUTOMATIONINTRODUCTIONSA1 Scope .SA1CONSTRUCTIONSA2 General SA1SA3 Electrical Rating SA1JUNE 26, 2015UL 498B4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULPERFORMANCESA4 General SA2SA5 Overload Test .SA2SA6 Endurance Test .SA4RATIN
13、GSA7 Details .SA7SA7.1 Input .SA7SA7.2 Output .SA8MARKINGSSA8 Details .SA8INSTALLATION INSTRUCTIONSSA9 General .SA11APPENDIX AStandards for ComponentsA1JUNE 26, 2015 UL 498B 5UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULINTRODUCTION1 Scope1
14、.1 These requirements cover a receptacle with integral switching means rated 600 V or less, used inordinary dry locations and intended for connection to a branch circuit in accordance with the NationalElectrical Code, NFPA 70.1.2 A receptacle with integral switching means covered by this Outline sha
15、ll meet the followingrequirements:a) No voltage greater than 600 V above ground will be present in the device,b) An isolation transformer, if provided, will generally furnish power at a lower potential than theprimary voltage; andc) The output of the device will not be located in a circuit operating
16、 at greater than 600 Vabove ground.d) The switching device shall be integral to the receptacle.e) A receptacle that is marked with the symbol shown in Table SA8.1 Reference No. 2 anddoes not employ an integral switching means intended for energy management and buildingautomation, are covered by the
17、Standard for Attachment Plugs and Receptacles, UL 498.1.3 This Outline does not directly apply to, but may supplement the following standards:a) Devices produced integrally with flexible cord or cable, covered by the Standard for CordSets and Power-Supply Cords, UL 817;b) Current taps and adapters c
18、overed by the Standard for Current Taps and Adapters, UL498A;c) Devices employing male or female screwshells, covered by the Standard for Lampholders,UL 496;d) Single and multipole connectors intended for factory assembly to copper or copper alloyconductors or printed wiring boards for use in data,
19、signal, control and power applications withinand between electrical equipment, covered by the Standard for Component Connectors forData, Signal, Control and Power Applications, UL 1977;e) Devices intended for installation and use in hazardous (classified) locations in accordancewith the National Ele
20、ctrical Code, NFPA 70, covered by the Standard for Explosion-Proof andDust-Ignition-Proof Equipment for Use in Hazardous (Classified) Locations, UL 1203;f) Devices intended for use with telecommunications networks, covered by the Standard forInformation Technology Equipment Safety Part 1: General Re
21、quirements, UL 60950-1, orthe Standard for Communications Circuit Accessories, UL 1863;g) Devices incorporating ground-fault circuit interruption circuitry, covered by the Standard forGround-Fault Circuit Interrupters, UL 943;JUNE 26, 2015UL 498B6UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER RE
22、PRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULh) Direct plug-in devices incorporating transient voltage surge suppression circuitry, covered bythe Standard for Surge Protective Devices, UL 1449;i) Direct plug-in devices incorporating electromagnetic interference filter circuitry, covered by th
23、eStandard for Electromagnetic Interference Filters, UL 1283;j) Cord-connected, relocatable power taps intended only for indoor use as a temporaryextension of a grounding alternating-current branch circuit for general use, covered by theStandard for Relocatable Power Taps, UL 1363.k) Energy managemen
24、t equipment covered by the Standard for Energy ManagementEquipment, UL 916.2 Components2.1 Except as indicated in 2.2, a component of a product covered by this Outline shall comply with therequirements for that component. See Appendix A for a list of standards covering components generallyused in th
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ULSUBJECT498B2015ULOUTLINEFORINVESTIGATIONRECEPTACLESWITHINTEGRALSWITCHINGMEANSISSUE2 带有 整体 切换 装置 插座

链接地址:http://www.mydoc123.com/p-1069446.html