UL SUBJECT 497E-2011 OUTLINE OF INVESTIGATION FOR PROTECTORS FOR ANTENNA LEAD-IN CONDUCTORS (Issue Number 4)《天线引入导线用保护器调查大纲》.pdf
《UL SUBJECT 497E-2011 OUTLINE OF INVESTIGATION FOR PROTECTORS FOR ANTENNA LEAD-IN CONDUCTORS (Issue Number 4)《天线引入导线用保护器调查大纲》.pdf》由会员分享,可在线阅读,更多相关《UL SUBJECT 497E-2011 OUTLINE OF INVESTIGATION FOR PROTECTORS FOR ANTENNA LEAD-IN CONDUCTORS (Issue Number 4)《天线引入导线用保护器调查大纲》.pdf(28页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULJanuary 25, 20111SUBJECT 497EOUTLINE OF INVESTIGATIONFORPROTECTORS FOR ANTENNA LEAD-IN CONDUCTORSIssue No. 4January 25, 2011Summary of TopicsThis is the Fourth issue of the Outline of Investigati
2、on for Protectors forAntenna Lead-In Conductors, Subject 497E, which covers devices that areused to limit surges on the cable that connects the antenna to thereceiver/transmitter electronics and are connected between theconductors and the grounded shield or other ground connection.COPYRIGHT 2011 UND
3、ERWRITERS LABORATORIES INC.UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULJANUARY 25, 2011SUBJECT 497E2No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULCONTENTSINTROD
4、UCTION1 Scope .52 Components .63 Units of Measurement 64 Undated References 75 Glossary .7CONSTRUCTION6 General 87 Enclosures .87.1 General .87.2 Sheet metal 97.3 Nonmetallic 98 Protection Against Corrosion .99 Wiring Connections .99.1 Coaxial connections 99.2 Grounding .910 Components .1010.1 Gener
5、al .1010.2 Arrester assemblies 1110.3 Electrical insulation material .1110.4 Polymeric materials .11PERFORMANCE11 General 1112 Performance Verification Tests .1412.1 General .1412.2 Impulse sparkover voltage measurement test (not applicable to dc shorting typeprotectors) .1512.3 Insulation resistanc
6、e test (not applicable to dc shorting type protectors) .1612.4 Breakdown voltage measurement test (not applicable to dc shorting type protectors) .1612.5 Residual voltage measurement test (dc shorting type protectors) .1712.6 Combination devices 1813 Maximum Discharge Current (Imax) Test .1814 Nomin
7、al Discharge Current (In) Test (Optional) .1915 Discharge Test .2016 Conditioning Tests 2216.1 Impulse endurance conditioning test 2216.2 Drop test 2216.3 Thermal cycling test 2216.4 Humidity conditioning test .2316.5 Indoor corrosion tests .2316.6 Outdoor corrosion tests .2317 Capacitor Thermal Agi
8、ng Test 2418 Component Temperature Test 2519 Dielectric Voltage-Withstand Test 2620 Distortion Test .26JANUARY 25, 2011 SUBJECT 497E 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL21 Impact Test (Polymeric Enclosures) .2622 Water Spray Test
9、(Outdoor Units Only) 2623 Ultraviolet Light and Water Exposure (Outdoor Units Only) 2724 Tensile Strength and Elongation Tests 2725 Air Oven Aging Test 2726 Ozone Exposure Test 27MARKINGS27 General 27INSTALLATION INSTRUCTIONS28 General 28JANUARY 25, 2011SUBJECT 497E4UL COPYRIGHTED MATERIAL NOT AUTHO
10、RIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULINTRODUCTION1 Scope1.1 This Outline of Investigation covers protectors for antenna lead-in conductors. These devices areused to limit surges on the cable that connects the antenna to the receiver/transmitter electronics and arec
11、onnected between the conductors and the grounded shield or other ground connection. Typicalapplications include antenna installations for radio and television receiving equipment, amateur radiotransmitting and receiving equipment, cellular telephone towers and WiMax or WiFi wireless networks.1.2 As
12、covered by these requirements, protectors for antenna lead-in conductors typically consists of airgap arresters, gas tube arresters, solid-state arresters or quarter-wave stub type devices, or combinationsof these devices. Other technologies are not excluded. They may or may not contain additionalco
13、mponents such as inductors or blocking capacitors. These protectors are intended to protectequipment, wiring, and personnel at the premises against the effects of excessive potentials and currentson the conductors caused by lightning.1.3 These devices operate to divert a surge current to earth, and
14、control the residual voltage (also knownas let-through voltage) to a suitable level. Once the surge current has subsided, the device automaticallyreturns normal operation and reset to a state ready to receive the next surge. Residual voltage limits ortheir suitability to minimize damage to connected
15、 equipment is not within the scope of these requirements.1.4 These protectors are investigated for their maximum discharge current (Imax) capability using an 8/20current waveform. This is the maximum impulse current the protector can withstand, including afterenvironmental conditioning, without affe
16、cting its surge limiting capability or creating a risk of fire,fragmentation or electrical shock.1.5 This Outline does not cover the following:a) Lightning protective devices for the protection of secondary distribution wiring systems andequipment.b) Antenna discharge units for radio and television
17、receiving appliances that are covered by theStandard for Antenna-Discharge Units, UL 452.c) Lightning conductor and air terminals for connection of lightning rods for building protection.d) Protectors for fire alarm signaling circuits that are covered by the Standard for Protectors forData Communica
18、tions and Fire-Alarm Circuits, UL 497B.e) Equipment covered by the Standard for Secondary Protectors for Communications Circuits,UL 497A.f) Equipment covered by the Standard for Surge Protective Devices, UL 1449.g) Equipment covered by the Standard for Protectors for Paired-Conductor CommunicationsC
19、ircuits, UL 497.h) Equipment covered by the Standard for Protectors for Coaxial Communications Circuits, UL497C.i) DC blocking connectors or components that do not have lightning protection as their primaryfunction.JANUARY 25, 2011 SUBJECT 497E 5UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REP
20、RODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULj) Applications where follow-on currents may occur, such as installations where communicationswiring is routed on shared facilities with electrical distribution systems.1.6 Special installation methods are required for equipment connected to wire-li
21、ne communicationfacilities serving high-voltage electric power stations operating at greater than 1 kV. These requirementsdo not cover the equipment or devices used in the design of such installations. Special system designrequirements, such as those covered by Recommended Practice for the Protectio
22、n of Wire-LineCommunication Facilities Serving Electric Power Locations, IEEE 487, shall be followed to reduce therisks associated with wire-line communication facilities serving such power stations.2 Components2.1 Except as indicated in 2.2, a component of a product covered by this Outline shall co
23、mply with therequirements for that component.2.2 A component is not required to comply with a specific requirement that:a) Involves a feature or characteristic not required in the application of the component in theproduct covered by this outline orb) Is superseded by a requirement in this outline.2
24、.3 A component shall be used in accordance with its rating established for the intended conditions ofuse.2.4 Specific components are incomplete in construction features or restricted in performance capabilities.Such components are intended for use only under limited conditions, such as certain tempe
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ULSUBJECT497E2011OUTLINEOFINVESTIGATIONFORPROTECTORSFORANTENNALEADINCONDUCTORSISSUENUMBER4 天线 引入 导线 保护

链接地址:http://www.mydoc123.com/p-1069445.html