《UL SUBJECT 48A-2005 OUTLINE OF INVESTIGATION FOR NEON SIGNS FOR USE IN DWELLINGS (RESIDENTIAL) (Issue 1)《居住场所(住宅)用霓虹灯调查大纲 发布编号 1》.pdf》由会员分享,可在线阅读,更多相关《UL SUBJECT 48A-2005 OUTLINE OF INVESTIGATION FOR NEON SIGNS FOR USE IN DWELLINGS (RESIDENTIAL) (Issue 1)《居住场所(住宅)用霓虹灯调查大纲 发布编号 1》.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULFebruary 18, 20051SUBJECT 48AOUTLINE OF INVESTIGATIONFORNEON SIGNS FOR USE IN DWELLINGS (RESIDENTIAL)1February 18, 2005COPYRIGHT 2005 UNDERWRITERS LABORATORIES INC.UL COPYRIGHTED MATERIAL NOT AUT
2、HORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULFEBRUARY 18, 2005SUBJECT 48A2No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULCONTENTSINTRODUCTION1 Scope .42 General 4CONSTRUCTION3 Enclosure 44 Acce
3、ssibility 4PERFORMANCE5 Abnormal operation .8MARKINGS6 General 9FEBRUARY 18, 2005 SUBJECT 48A 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULINTRODUCTION1 Scope1.1 This outline of investigation covers cord connected and permanently connected
4、 neon signs intendedfor use in residences. In addition to the applicable requirements in the Standard for Electric Signs, UL 48and the Standard for Neon Transformers and Power Supplies, UL 2161, the following are supplementaryrequirements that also apply to neon signs intended for use in dwellings (
5、residential).2 General2.1 The maximum output voltage shall be limited to 10,000 volts, and 5,000 volts to ground, withmaximum 15 mA output current, or 7,500 volts with maximum 30 mA output current.CONSTRUCTION3 Enclosure3.1 Except as noted in 3.2, all live parts shall be enclosed with no openings pr
6、ovided in the enclosureother than the opening used for the power supply connection when permanently connected to a source ofsupply.3.2 Neon transformers and power supplies may be provided with openings provided they comply with theaccessibility requirements of section 4.4 Accessibility4.1 All expose
7、d live parts shall be inaccessible to contact. Uninsulated live parts internal to a neontransformer or power supply or other component that is in excess of 15 volts rms in a damp or wet locationand 30 volts in a dry location shall be inaccessible to contact by a straight metal strip that is 4 inches
8、(101.6 mm) long by 1/2 inch (12.7 mm) wide, and 1/16 inch (1.6 mm) thick, when applied through theopening with a force not greater than one pound (4.4 N). The ventilation openings of a cord connectedneon transformer or power supply complying with Neon Transformers and Power Supplies, UL 2161, arecon
9、sidered to comply with this requirement. Permanently connected neon transformers and powersupplies that comply with Neon Transformers and Power Supplies, UL 2161, and are intended for use indwellings shall additionally comply with the accessibility requirements in this section.4.2 Where an accessibi
10、lity barrier is provided to prevent contact with live parts in excess of 1000 voltsrms (1414 V peak) to ground, it shall comply with the dielectric voltage-withstand test in Electric Signs, UL48. The test shall be conducted across the combination of the barrier material, spacing between barriersand
11、live parts, and any other material between current-carrying parts and the user or service personnelside of the barrier. The test potential shall be applied between the current-carrying part made inaccessibleby the barrier and the edge of the straight metal strip specified in 4.1. The straight metal
12、strip shall be incontact with the opposite side of the barrier. The test potential shall be 1750 volts plus 1.25 times themaximum operating voltage of the part(s) made inaccessible.FEBRUARY 18, 2005SUBJECT 48A4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PER
13、MISSION FROM UL4.3 Other than those components that have been evaluated to comply with the requirements in thisOutline of Investigation for use in Dwellings, all insulated live parts, including neon tubing electrodes,electrode enclosures, and GTO sleevings, shall be inaccessible to contact by the Ac
14、cessibility Probe, 4.1.This is generated text for figtxt.FEBRUARY 18, 2005 SUBJECT 48A 5UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULFigure 4.1Articulate probe with web stopFEBRUARY 18, 2005SUBJECT 48A6UL COPYRIGHTED MATERIAL NOT AUTHORIZED
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ULSUBJECT48A2005OUTLINEOFINVESTIGATIONFORNEONSIGNSFORUSEINDWELLINGSRESIDENTIALISSUE1 居住 场所 住宅 霓虹灯 调查

链接地址:http://www.mydoc123.com/p-1069443.html