《UL 1977-2016 UL Standard for Safety Component Connectors for Use in Data Signal Control and Power Applications (Third Edition Reprint with revisions through and including March 7 2.pdf》由会员分享,可在线阅读,更多相关《UL 1977-2016 UL Standard for Safety Component Connectors for Use in Data Signal Control and Power Applications (Third Edition Reprint with revisions through and including March 7 2.pdf(28页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 1977 Component Connectors for Use in Data, Signal, Control and Power ApplicationsUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL
2、COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Component Connectors for Use in Data, Signal, Control and Power Applications, UL 1977 Third Edition, Dated January 7, 2016 SUMMARY OF TOPICS These new edition to UL 1977
3、 includes the revision of the thickness requirement for ammability test specimens The revised requirements are substantially in accordance with Proposal(s) on this subject dated December 4, 2015. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or tra
4、nsmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwise without prior permission of UL. UL provides this Standard as is without warranty of any kind, either expressed or implied, including but not limited to, the implied warranties of merchantability or tness
5、for any purpose. In no event will UL be liable for any special, incidental, consequential, indirect or similar damages, including loss of prots, lost savings, loss of data, or any other damages arising out of the use of or the inability to use this Standard, even if UL or an authorized UL representa
6、tive has been advised of the possibility of such damage. In no event shall ULs liability for any damage ever exceed the price paid for this Standard, regardless of the form of the claim. Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold UL harmless fro
7、m and against any loss, expense, liability, damage, claim, or judgment (including reasonable attorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronic Standard on the purchasers computer system. The requirements in this Standard are now in effect, exce
8、pt for those paragraphs, sections, tables, gures, and/or other elements of the Standard having future effective dates as indicated in the note following the affected item. The prior text for requirements that have been revised and that have a future effective date are located after the Standard, and
9、 are preceded by a SUPERSEDED REQUIREMENTS notice. JANUARY 7, 2016 UL 1977 tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL JANUARY 7, 2016 UL 1977 tr2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
10、DISTRIBUTION WITHOUT PERMISSION FROM UL JANUARY 7, 2016 1 UL 1977 Standard for Component Connectors for Use in Data, Signal, Control and Power Applications First Edition December, 1995 Second Edition December, 2007 Third Edition January 7, 2016 This UL Standard for Safety consists of the Third Editi
11、on. Comments or proposals for revisions on any part of the Standard may be submitted to UL at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards Development System (CSDS) at http:/. ULs Standards for Safety are copyrighted by UL. Neither a printed n
12、or electronic copy of a Standard should be altered in any way. All of ULs Standards and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive property of UL. COPYRIGHT 2016 UNDERWRITERS LABORATORIES INC.UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER
13、 REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL JANUARY 7, 2016 UL 1977 2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS INTRODUCTION 1 Scope .4 2 Glossary .6 3 Components 6 4 Units of Measurement .7 5
14、References .7 CONSTRUCTION 6 General 7 7 Insulating Materials 7 8 Current-Carrying Parts .8 9 Grounding and Dead-Metal Parts .9 10 Assembly 10 10.1 General .10 10.2 Accessibility of live parts 10 10.3 Connection between mating devices 12 11 Spacings 12 PERFORMANCE 12 General 13 13 Accelerated Aging
15、Test 14 13.1 Rubber compounds .14 13.2 PVC compounds .14 14 Mold Stress Relief Test 14 15 Overload Test 15 16 Temperature Test .16 17 Dielectric Voltage-Withstand Test .17 18 Resistance To Arcing Test .18 19 Conductor Secureness Test 19 20 Flammability Test .19 21 Grounding Impedance Test 20 RATINGS
16、 22 General 20 MARKINGS 23 General 20 APPENDIX A Standards for ComponentsA1 JANUARY 7, 2016 UL 1977 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL INTRODUCTION 1 Scope 1.1 These requirements cover single and multipole connectors, intended
17、for factory assembly to copper or copper alloy conductors or printed wiring boards, for use in data, signal, control and power applications within and between electrical equipment. 1.2 These requirements apply to devices categorized as follows (See Figure 1.1): a) Type 0 rated less than 8.3 A and le
18、ss than 30 V rms (42 V peak); b) Type 1A rated less than 8.3 A and from 30 V up to and including 600 V ac or dc, or both; c) Type 1B rated from 8.3 A up to and including 200 A, and less than 30 V rms (42 V peak); d) Type 2 rated from 8.3 A to less than 31 A and from 30 V up to and including 600 V ac
19、 or dc or both; e) Type 3 rated from 31 A up to and including 200 A and from 30 V up to and including 600 V ac or dc, or both. f) Type 4 rated from greater than 200 A up to and including 1000 A, and up to and including 6 0 0Va co rd c . g) Type 5 rated less than 31 A and from 601 V up to and includi
20、ng 6000 V ac or dc, or both. Type designations used in this Standard only serve as a guide to determine appropriate requirements, and do not represent an assigned rating. A device without an assigned current rating is considered to be either a Type 0 or Type 1A depending upon the assigned voltage ra
21、ting. This is generated text for gtxt. JANUARY 7, 2016 UL 1977 4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 1.3 This standard does not directly apply to the following devices, but may be used to supplement the requirements within these s
22、tandards when a device is evaluated to these standards: a) Devices produced integrally with exible cord or cable that are covered by the Standard for Cord Sets and Power-Supply Cords, UL 817; b) Devices intended for connection to the branch circuit, such as attachment plugs, cord connectors, recepta
23、cles, inlets, and outlets, that are covered by the Standard for Attachment Plugs and Receptacles, UL 498; c) Devices solely intended for direct connection to the branch circuit in accordance with the National Electrical Code, NFPA 70, and that are provided with contacts of the pin and sleeve type, t
24、hat are covered by the Standard for Plugs, Receptacles, and Cable Connectors of the Pin and Sleeve Type, UL 1682; d) Devices consisting of wiring terminals and supporting blocks intended for the connection of wiring that are covered by the Standard for Terminal Blocks, UL 1059; e) Devices intended f
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL19772016ULSTANDARDFORSAFETYCOMPONENTCONNECTORSFORUSEINDATASIGNALCONTROLANDPOWERAPPLICATIONSTHIRDEDITIONREPRINTWITHREVISIONSTHROUGHANDINCLUDINGMARCH72PDF

链接地址:http://www.mydoc123.com/p-1067732.html