SSPC PA 6-2002 Fiberglass-Reinforced Plastic (FRP) Linings Applied to Bottoms of Carbon Steel Aboveground Storage Tanks (NACE NO 10)《适用于碳钢地面存储罐底部的玻璃钢(FRP)衬里 NACE 第10号》.pdf
《SSPC PA 6-2002 Fiberglass-Reinforced Plastic (FRP) Linings Applied to Bottoms of Carbon Steel Aboveground Storage Tanks (NACE NO 10)《适用于碳钢地面存储罐底部的玻璃钢(FRP)衬里 NACE 第10号》.pdf》由会员分享,可在线阅读,更多相关《SSPC PA 6-2002 Fiberglass-Reinforced Plastic (FRP) Linings Applied to Bottoms of Carbon Steel Aboveground Storage Tanks (NACE NO 10)《适用于碳钢地面存储罐底部的玻璃钢(FRP)衬里 NACE 第10号》.pdf(13页珍藏版)》请在麦多课文档分享上搜索。
1、SSPC Publication No. 02-05 Item No. 21093Joint StandardSSPC-PA 6/NACE No. 10Fiberglass-Reinforced Plastic (FRP) LiningsApplied to Bottoms of Carbon Steel AbovegroundStorage TanksThis SSPC: The Society for Protective Coatings/NACE International (NACE) standard represents aconsensus of those individua
2、l members who have reviewed this document, its scope, andprovisions. It is intended to aid the manufacturer, the consumer, and the general public. Itsacceptance does not in any respect preclude anyone, whether he has adopted the standard or not,from manufacturing, marketing, purchasing, or using pro
3、ducts, processes, or procedures notaddressed in this standard. Nothing contained in this SSPC/NACE standard is to be construed asgranting any right, by implication or otherwise, to manufacture, sell, or use in connection with anymethod, apparatus, or product covered by Letters Patent, or as indemnif
4、ying or protecting anyoneagainst liability for infringement of Letters Patent. This standard represents current technology andshould in no way be interpreted as a restriction on the use of better procedures or materials.Neither is this standard intended to apply in all cases relating to the subject.
5、 Unpredictablecircumstances may negate the usefulness of this standard in specific instances. SSPC and NACEassume no responsibility for the interpretation or use of this standard by other parties and acceptresponsibility for only those official interpretations issued by SSPC or NACE in accordance wi
6、ththeir governing procedures and policies which preclude the issuance of interpretations by individualvolunteers.Users of this SSPC/NACE standard are responsible for reviewing appropriate health, safety,environmental, and regulatory documents and for determining their applicability in relation to th
7、isstandard prior to its use. This SSPC/NACE standard may not necessarily address all potentialhealth and safety problems or environmental hazards associated with the use of materials,equipment, and/or operations detailed or referred to within this standard. Users of thisSSPC/NACE standard are also r
8、esponsible for establishing appropriate health, safety, andenvironmental protection practices, in consultation with appropriate regulatory authorities ifnecessary, to achieve compliance with any existing applicable regulatory requirements prior to theuse of this standard.CAUTIONARY NOTICE: SSPC/NACE
9、 standards are subject to periodic review, and may berevised or withdrawn at any time without prior notice. The user is cautioned to obtain the latestedition. SSPC and NACE require that action be taken to reaffirm, revise, or withdraw this standardno later than five years from the date of initial pu
10、blication.Approved February 20022002 SSPC: The Society for Protective Coatings and NACE InternationalISBN 1-57590-129-3SSPC: The Society for Protective Coatings40 24th Street, Sixth FloorPittsburgh, PA 15222(telephone +1 412/281-2331)NACE International1440 South Creek DriveHouston, TX 77084-4906(tel
11、ephone +1 281/228-6200)Printed by SSPC: The Society for Protective CoatingsSSPC-PA 6/NACE No. 10SSPC: The Society for Protective Coatings i_ForewordThis standard recommended practice specifies the procedures to design, apply, and inspectfiberglass-reinforced plastic (FRP) linings that are applied in
12、ternally to the bottom of carbon steelaboveground storage tanks (ASTs). FRP linings are used worldwide to prevent the corrosion anddeterioration of storage tank bottoms in petroleum, petrochemical, and other services. Experiencehas shown that the useful life of an FRP lining may exceed 25 years. API
13、(1)Standard 6531permits aminimum remaining thickness of the tank bottom plate to be 1.25 mm (0.050 in.) when lined with FRPcompared to a thickness of 2.5 mm (0.10 in.) if unlined or lined with a nonreinforced coating systemand not equipped with a tank bottom leak detection system. This standard will
14、 serve as a resource forfacility owners preparing specifications to achieve successful lining applications in ASTs in thepetroleum/petrochemical industry. The practices described are also useful during preparation ofspecifications for ASTs in other services.This joint standard was prepared by the SS
15、PC/NACE Task Group 009 on Fiberglass-ReinforcedPlastic Linings for Aboveground Storage Tank Floors. This task group is administered by NACESpecific Technology Group (STG) 80 on Intersociety Joint Coatings Activities, and also sponsored bySTG 03 on Protective Coatings and Linings: Immersion/Buried. T
16、his standard is published by SSPCand by NACE under the auspices of STG 80._(1)American Petroleum Institute (API), 1220 L St. NW, Washington, DC 20005-4070.SSPC-PA 6/NACE No. 10ii SSPC: The Society for Protective Coatings_Joint StandardSSPC-PA 6/NACE No. 10Fiberglass-Reinforced Plastic (FRP) Linings
17、Applied toBottoms of Carbon Steel Aboveground Storage TanksContents1. General .12. Definitions .13. Lining Materials 24. Storage Tank Preparation .35. Applicator Qualifications and Submissions .36. Surface Preparation .37. Holding Primer Application 48. Caulking and Coving Application 49. Laminate A
18、pplication .510. Roof Leg Bearing (Striker) Plates .711. FRP Lining Inspection, Testing, and Repair7References8Bibliography 9Appendix A: Documents and Standards to Be Used in Conjunction with this Standard.10Figure 1: Squeegee Application of Caulk 4Figure 2: Schematic of Overlap at Floor Plate or St
19、riker Plate Showing Caulking andSingle Laminate Application.5Figure 3: Schematic of Caulking and Single Laminate Applied at Juncture of Sketch Plateand Shell Plate5Figure 4: Wet-Film Thickness Gauge 6Table 1: Items Evaluated by Inspector 8_SSPC-PA 6/NACE No. 10SSPC: The Society for Protective Coatin
20、gs 1_Section 1: General1.1 Procedures outlined below and detailed in subsequentsections of this standard shall be followed for the successfulapplication of a FRP lining system.1.1.1 Abrasive blast clean the storage tank bottomand, as a minimum, the lower 60 cm (24 in.) of the tankshell. The owner sh
21、ould confirm that this minimumtank shell height is acceptable. Inspect cleanedsurfaces just prior to primer or coating application.1.1.2 If required, apply primer to the storage tank floorand the lower 60 cm (24 in.) of the tank shell.1.1.3 Apply caulk to the properly prepared tank floor,deep pits,
22、equipment supports, striker (bearing) plates,and chine angle, as required.1.1.4 Apply resin and glass reinforcement to the tankbottom and lower shell course. If a two-layer or doublelaminate system is applied, extend the first layer 45 cm(18 in.) up the tank shell and the second 30 cm (12 in.)up the
23、 tank shell. At least 15 cm (6 in.) of blasted andprimed shell wall shall be visible above the first coat oflaminate.1.1.5 Repair defects in the laminate prior to theapplication of the topcoat. (See Section 2.)1.1.6 Apply a topcoat to the laminate applied to thefloor and to the tank shell.1.1.7 Duri
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SSPCPA62002FIBERGLASSREINFORCEDPLASTICFRPLININGSAPPLIEDTOBOTTOMSOFCARBONSTEELABOVEGROUNDSTORAGETANKSNACENO10

链接地址:http://www.mydoc123.com/p-1054450.html