SAE AS 22759 51-2013 WIRE ELECTRICAL FLUOROPOLYMER-INSULATED CROSSLINKED MODIFIED ETFE LOW FLUORIDE LIGHTWEIGHT SILVER-COATED HIGH STRENGTH COPPER ALLOY 200 C 600 VOLT《200℃、600 V轻量.pdf
《SAE AS 22759 51-2013 WIRE ELECTRICAL FLUOROPOLYMER-INSULATED CROSSLINKED MODIFIED ETFE LOW FLUORIDE LIGHTWEIGHT SILVER-COATED HIGH STRENGTH COPPER ALLOY 200 C 600 VOLT《200℃、600 V轻量.pdf》由会员分享,可在线阅读,更多相关《SAE AS 22759 51-2013 WIRE ELECTRICAL FLUOROPOLYMER-INSULATED CROSSLINKED MODIFIED ETFE LOW FLUORIDE LIGHTWEIGHT SILVER-COATED HIGH STRENGTH COPPER ALLOY 200 C 600 VOLT《200℃、600 V轻量.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、AEROSPACE STANDARD WIRE, ELECTRICAL, FLUOROPOLYMER-INSULATED, CROSSLINKED MODIFIED ETFE, LOW FLUORIDE, LIGHTWEIGHT, SILVER-COATED HIGH STRENGTH COPPER ALLOY, 200 C, 600 VOLTAS22759/51Copyright 2013 SAE International All rights reserved. No part of this publication may be reproduced, stored in a retr
2、ieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE. TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada) Tel: +1 724-776-4970 (outside USA) Fax: 724-776-0790 Email: Custo
3、merServicesae.org SAE WEB ADDRESS: http:/www.sae.org ISSUED 2013-07THIRD ANGLE PROJECTION CUSTODIAN: AE-8/AE-8D FEDERAL SUPPLY CLASS 6145 AS22759/51SHEET 1 OF 3PROCUREMENT SPECIFICATION: AS22759SAE Technical Standards Board Rules provide that: “This report ispublishedby SAE toadvance thestate of tec
4、hnicalandengineering sciences. Theuse ofthis report is entirely voluntary, andits applicability and suitability forany particular use,including any patent infringement arising therefrom, isthe soleresponsibilityofthe user.”SAE reviews eachtechnicalreport at least every five years at which time itmay
5、 berevised, reaffirmed, stabilized, orcancelled. SAE invites yourwrittencomments andsuggestions. SAE values your input. To provide feedbackon this Technical Report, please visit http:/www.sae.org/technical/standards/AS22759/51RATIONALE DETAIL SPECIFICATION REQUIRED TO STANDARDIZE COMMERCIAL WIRE FOR
6、 USER APPLICATIONS. NOTICE THE COMPLETE REQUIREMENTS FOR PROCURING THE PRODUCT DESCRIBED HEREIN SHALL CONSIST OF THIS DOCUMENT AND THE LATEST ISSUE OF AS22759. FIGURE 1 - GENERAL CONFIGURATION TABLE 1 - CONSTRUCTION DETAILS PART NO. 1/ WIRESIZESTRANDING (NUMBER OF STRANDS X AWG GAUGE OF STRANDS) 2/D
7、IAMETER OF STRANDEDCONDUCTOR (INCHES) FINISHED WIRE (MIN) (MAX) RESISTANCE AT 20 C (68 F) (OHMS/1000 FEET)MAXDIAMETER(INCHES) WEIGHT (POUNDS/ 1000 FEET) (MAX)M22759/51-30-* 30 7 X 38 .0105 .0124 117.4 .024 .002 .66 M22759/51-28-* 28 7 X 36 .0135 .0154 74.4 .027 . 002 .91 M22759/51-26-* 26 19 X 38 .0
8、175 .0204 44.8 .032 .002 1.4 M22759/51-24-* 24 19 X 36 .0225 .0244 28.4 .037 .002 2.0 M22759/51-22-* 22 19 X 34 .0285 .0314 17.5 .043 .002 2.9 M22759/51-20-* 20 19 X 32 .0365 .0394 10.7 .050 .002 4.4 1/ PART NUMBER: THE ASTERISKS IN THE PART NUMBER COLUMN, TABLES 1 AND 2, SHALL BE REPLACED BY COLOR
9、CODE DESIGNATORS IN ACCORDANCE WITH MIL-STD-681. EXAMPLES: SIZE 20, WHITE-M22759/51- 20-9; WHITE WITH ORANGE STRIPE M22759/51-20-93. PRINTING OF COLOR CODE DESIGNATOR ON SURFACE OF WIRE INSULATION IS NOT REQUIRED. 2/ CONDUCTOR SHALL CONFORM TO MIL-DTL-29606 TYPE SCA SMALL DIAMETER SILVER PLATED COPP
10、ER CONDUCTOR. Copyright SAE International Provided by IHS under license with SAENot for ResaleNo reproduction or networking permitted without license from IHS-,-,-AEROSPACE STANDARD AS22759/51SHEET 2 OF 3WIRE, ELECTRICAL, FLUOROPOLYMER-INSULATED, CROSSLINKED MODIFIED ETFE, LOW FLUORIDE, LIGHTWEIGHT,
11、 SILVER-COATED HIGH STRENGTH COPPER ALLOY, 200 C, 600 VOLTTABLE 2 - PERFORMANCE DETAILS BEND TESTING PART NO. MANDREL DIAMETER (INCHES) (3%) TEST LOAD (POUNDS) (3%) CROSSLINKING PROOF, IMMERSION AND LIFE CYCLE TESTS COLDBENDTESTCROSSLINKING PROOF, IMMERSION AND LIFE CYCLE TESTS COLD BENDTESTM22759/5
12、1-30-* .250 .375 .125 .500 M22759/51-28-* .250 .375 .125 .500 M22759/51-26-* .375 .500 .125 .500 M22759/51-24-* .375 .500 .250 1.00 M22759/51-22-* .500 .750 .375 1.00 M22759/51-20-* .500 .750 .500 1.00 REQUIREMENTS: THE COMPLETE REQUIREMENTS FOR PROCURING THE PRODUCT DESCRIBED HEREIN SHALL CONSIST O
13、F THIS DOCUMENT AND THE LATEST ISSUE OF AS22759. CONFIGURATION: WIRE SHALL BE CONSTRUCTED IN ACCORDANCE WITH FIGURE 1 AND TABLE 1. INSULATION THICKNESS: .005 INCH (MIN) PHYSICAL PROPERTIES OF INSULATION: PULLED AT 2 INCHES PER MINUTE. TENSILE STRENGTH, 5000 LBF/INCH2(MIN) ELONGATION, 75% (MIN) WIRE
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便