NF L53-201-031-2008 Aerospace series - Electrical contacts used in elements of connection - Part 031 contacts electrical coaxial shielded size 12 female type D crimp class R - Pro.pdf
《NF L53-201-031-2008 Aerospace series - Electrical contacts used in elements of connection - Part 031 contacts electrical coaxial shielded size 12 female type D crimp class R - Pro.pdf》由会员分享,可在线阅读,更多相关《NF L53-201-031-2008 Aerospace series - Electrical contacts used in elements of connection - Part 031 contacts electrical coaxial shielded size 12 female type D crimp class R - Pro.pdf(27页珍藏版)》请在麦多课文档分享上搜索。
1、NF EN 3155-031janvier 2008Ce document est usage exclusif et non collectif des clients Saga Web.Toute mise en rseau, reproduction et rediffusion, sous quelque forme que ce soit,mme partielle, sont strictement interdites.This document is intended for the exclusive and non collective use of Saga Web cu
2、stomers.All network exploitation, reproduction and re-dissemination,even partial, whatever the form (hardcopy or other media), is strictly prohibited.Saga Web Pour SHANGHAI INTERNAT SCIENCE la classe R correspond une gamme de tempratures de fonctionnement comprise entre 65 C et 150 C. 4.2 Dimensions
3、 et masse Voir Figure 1. Les dimensions et les tolrances sont donnes en millimtres et sappliquent aprs traitement de surface. Figure 1 3) Publi comme Rapport Technique ASD la date de publication de la prsente norme. EN 3155-031:2006 (E) 64.3 Marking by colour code Not applicable. 4.4 Material, surfa
4、ce treatment Outer body material (female) : copper alloy. Centre contact (male) : copper alloy. Crimp ferrule : copper alloy. Surface treatment : gold on appropriate undercoat, thickness of protection not specified, selective protection permitted. Hood : stainless steel. Dielectric : PTFE or equival
5、ent. 4.5 Permissible cables See Figure 2 and Table 1. Figure 2 Table 1 Dimensions of cableA B C DPermissiblecable group code Permissiblecable code according to TR 6058 min. max. min. max. min. max. min. max. A XY 0,28 0,33 1,52 1,68 2,00 2,20 2,41 2,67 B XQ 0,48 0,53 1,44 1,60 1,90 2,10 2,40 2,60 4.
6、6 Cable stripping and wiring method See Figure 3. EN 3155-031:2006 (F)64.3 Marquage par code de couleur Non applicable 4.4 Matriau, traitement de surface Matriau du corps extrieur (femelle) : alliage de cuivre. Contact central (mle) : alliage de cuivre. Frule sertir : alliage de cuivre. Traitement d
7、e surface : or sur une sous-couche approprie, paisseur de protection non spcifie, protection slective permise. Capuchon : acier inoxydable. Dilectrique : PTFE ou quivalent. 4.5 Cbles admissibles Voir Figure 2 et Tableau 1. Figure 2 Tableau 1 Dimensions du cbleA B C DCode groupe de cbles admissibles
8、Code cble admissible suivant le TR 6058 min. max. min. max. min. max. min. max. A XY 0,28 0,33 1,52 1,68 2,00 2,20 2,41 2,67 B XQ 0,48 0,53 1,44 1,60 1,90 2,10 2,40 2,60 4.6 Dnudage du cble et mthode de cblage Voir Figure 3. EN 3155-031:2006 (E) 7A Strip the insulation as shown below Slide the ferru
9、le on the wire B Comb and fold back the braid Strip the wire core as shown below C Fit the center contact over the core, crimp with tool in accordance with 4.7.1.D Set wired assembly into the body , crimp the body with tool in accordance with 4.7.1.E Installing and removal tool MIL-I-81969/14-04. Ke
10、y 1 2 mm to 2,5 mm 2 Crimping Figure 3 4.7 Tooling 4.7.1 Crimping tools Conform to MIL-DTL-22520, see Table 2. These selector numbers given in Table 2 shall be used for qualification of the contacts and in service, unless otherwise specified by the user. EN 3155-031:2006 (F)7A Dnuder lisolant comme
11、indiqu ci-dessous Glisser la frule sur le cble B Lisser et replier la tresse Dnuder lme comme indique ci-dessous C Ajuster le contact central sur lme, sertir avec loutil conformment 4.7.1. D Insrer lensemble cbl dans le corps , sertir le corps avec loutil conformment 4.7.1.E Outil dinsertion et dext
12、raction MIL-I-81969/14-04. Lgende 1 2 mm 2,5 mm 2 Sertissage Figure 3 4.7 Outillage 4.7.1 Outils de sertissage Conforme la MIL-DTL-22520, voir Tableau 2. Les numros de slecteurs indiqus dans le Tableau 2 doivent tre utiliss pour la qualification des contacts et en service, sauf spcification contrair
13、e de lutilisateur. EN 3155-031:2006 (E) 8Table 2 Tooling for crimping of centre contact Tooling for crimping of contact outer body Permissiblecable group code TR 6058 code Crimping tool Positioner Selector Crimping toolPositioner Selector A XY M22520/2-01 EN 4008-013 4 M22520/31-01EN 4008-014 N / A
14、B XQ M22520/2-01 EN 4008-013 5 M22520/31-01EN 4008-014 N / A It is the user responsibility, if the parameter in Tables 2 and 3 are changed for service use. 4.7.2 Insertion/extraction tools Conform to MIL-I-81969/14-04. 4.8 Tests See Table 3. Table 3 Applicable EN 2591- Designation of the test Notapp
15、licable According toEN 3155-001 Remarks 101 Visual examination X 102 Examination of dimensions and mass X See 4.2. X Test temperature: ambient 201 Contact resistance - low levelContact Maximum contact resistancemInitial After tests Centre 8 11 Outer Not applicable X202 Contact resistance at rated cu
16、rrentContact Maximum contact resistancemRatedcurrentA(2503 ) C (15003 ) C InitialAfter testsAfter tests Centre 8 11 12,8 1 Outer 2 23 3,2 7,5 204 Discontinuity of contacts in the microsecond range X Method B Duration of discontinuity: 100 ns. Test duration: throughout the duration of tests EN 2591-4
17、02 and EN 2591-403 (continued) EN 3155-031:2006 (F)8Tableau 2 Outillage de sertissage du contact central Outil de sertissage du corps extrieur de contact Code groupe de cbles admissibles Code TR 6058 Outil de sertissage PositionneurSlecteurOutil de sertissage PositionneurSlecteurA XY M22520/2-01 EN
18、4008-013 4 M22520/31-01 EN 4008-014 N / A B XQ M22520/2-01 EN 4008-013 5 M22520/31-01 EN 4008-014 N / A Pour lutilisation en service, il est de la responsabilit de lutilisateur si les paramtres des Tableaux 2 et 3 sont changs. 4.7.2 Outils dinsertion/dextraction Conforme la MIL-I-81969/14-04. 4.8 Es
19、sais Voir Tableau 3. Tableau 3 Applicable EN 2591- Dsignation de lessai Nonapplicable Suivant lEN 3155-001 Remarques 101 Examen visuel X 102 Examen des dimensions et masseX Voir 4.2. X Temprature dessai : ambiante 201 Rsistance du contact sous faible intensit Contact Rsistance maximale des contactsm
20、Initialement Aprs essaisCentral 8 11 Extrieur Non applicable X202 Rsistance de contact au courant nominal Contact Rsistance maximale des contactsmCourant nominal A(2503 ) C (15003 ) C InitialementAprsessaisAprs essais Central 8 11 12,8 1 Extrieur 2 23 3,2 7,5 204 Discontinuit des contacts dans la ga
21、mme des microsecondes X Mthode B Dure de la discontinuit : 100 ns. Dure de lessai : pendant toute la dure des essais EN 2591-402 et EN 2591-403 ( suivre) EN 3155-031:2006 (E) 9Table 3 (continued) Applicable EN 2591- Designation of the test Notapplicable According toEN 3155-001 Remarks 206 Measuremen
22、t of insulation resistance X Method C Mated contacts At ambient 5 GAt 150 C 2 G207 Voltage proof test X Method C Proof test voltage at sea level: 500 VAC r.m.s. between centre contact and outer contact Proof test voltage at altitude: 125 VAC r.m.s. at 1,1 kPa pressure (33 000 m) Leakage current: 2 m
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便