NEMA TC 2-2013 Electrical Polyvinyl Chloride (PVC) Conduit.pdf
《NEMA TC 2-2013 Electrical Polyvinyl Chloride (PVC) Conduit.pdf》由会员分享,可在线阅读,更多相关《NEMA TC 2-2013 Electrical Polyvinyl Chloride (PVC) Conduit.pdf(25页珍藏版)》请在麦多课文档分享上搜索。
1、NEMA Standards PublicationNational Electrical Manufacturers AssociationNEMA TC 2-2013Electrical Polyvinyl Chloride (PVC) ConduitNEMA TC 2-2013 Electrical Polyvinyl Chloride (PVC) Conduit NEMA TC 2-2013 Electrical Polyvinyl Chloride (PVC) Conduit Published by: National Electrical Manufacturers Associ
2、ation 1300 North 17th Street, Suite 900 Rosslyn, Virginia 22209-3801 www.nema.org 2013 National Electrical Manufacturers Association. All rights, including translation into other languages, reserved under the Universal Copyright Convention, the Berne Convention for the Protection of Literary and Art
3、istic Works, and the International and Pan American copyright conventions. 2013 National Electrical Manufacturers Association NOTICE AND DISCLAIMER The information in this publication was considered technically sound by a consensus among persons engaged in its development at the time it was approved
4、. Consensus does not necessarily mean there was unanimous agreement among every person participating in the development process. The National Electrical Manufacturers Association (NEMA) standards and guideline publications, of which the document herein is one, are developed through a voluntary stand
5、ards development process. This process brings together volunteers and/or seeks out the views of persons who have an interest in the topic covered by this publication. Although NEMA administers the process and establishes rules to promote fairness in the development of consensus, it does not write th
6、e documents, nor does it independently test, evaluate, or verify the accuracy or completeness of any information or the soundness of any judgments contained in its standards and guideline publications. NEMA disclaims liability for any personal injury, property, or other damages of any nature, whethe
7、r special, indirect, consequential, or compensatory, directly or indirectly resulting from the publication, use of, application, or reliance on this document. NEMA disclaims and makes no guaranty or warranty, express or implied, as to the accuracy or completeness of any information published herein,
8、 and disclaims and makes no warranty that the information in this document will fulfill any particular purpose(s) or need(s). NEMA does not undertake to guarantee the performance of any individual manufacturers or sellers products or services by virtue of this standard or guide. In publishing and ma
9、king this document available, NEMA is not undertaking to render professional or other services for or on behalf of any person or entity, nor is NEMA undertaking to perform any duty owed by any person or entity to someone else. Anyone using this document should rely on his or her own independent judg
10、ment or, as appropriate, seek the advice of a competent professional in determining the exercise of reasonable care in any given circumstance. Information and other standards on the topic covered by this publication may be available from other sources, which the user may wish to consult for addition
11、al views or information not covered by this publication. NEMA has no power, nor does it undertake to police or enforce compliance with the contents of this document. NEMA does not certify, test, or inspect products, designs, or installations for safety or health purposes. Any certification or other
12、statement of compliance with any health- or safety-related information in this document shall not be attributable to NEMA and is solely the responsibility of the certifier or maker of the statement. TC 2-2013 Page i 2013 National Electrical Manufacturers Association TABLE OF CONTENTS Page Section 1
13、GENERAL 1 1.1 Scope 1 1.2 Referenced Standards 1 Section 2 DEFINITIONS3 2.1 Definitions.3 Section 3 GENERAL REQUIREMENTS 4 3.1 Materials 4 3.1.1 Electrical Polyvinyl Chloride (PVC) Conduit (EPC) .4 3.1.2 Solvent Cements 4 3.2 Color4 3.3 Dimensions and Lengths.4 3.3.1 Average Outside Diameter .4 3.3.
14、2 Out-of-Roundness 4 3.3.3 Wall Thickness .4 3.3.4 Conduit Length.4 3.3.5 Minimum Inside Diameter 4 3.4 Joints .5 3.4.1 Molded Couplings .5 3.4.2 Integral Belled Ends 5 3.5 Inspections .5 Section 4 PERFORMANCE REQUIREMENTS .8 4.1 Qualification Tests .8 4.1.1 Definition .8 4.1.2 Deflection Resistance
15、8 4.1.3 Leakage at Solvent-Cemented Joints.8 4.2 Quality Control Tests 8 4.2.1 Definition .8 4.2.2 Conditioning.8 4.2.3 Dimensions8 4.2.4 Flattening 8 4.2.5 Workmanship .8 4.2.6 Impact Resistance 8 Section 5 TEST METHODS . 11 5.1 Conditioning, Test Conditions, and Sampling . 11 5.1.1 Conditioning Te
16、st Specimens . 11 5.1.2 Test Conditions 11 5.1.3 Sampling . 11 5.2 Dimensions . 11 5.2.1 Maximum and Minimum Outside Diameter (Out-of-Roundness) . 11 5.2.2 Outside Diameter (Average) . 11 5.2.3 Wall Thickness . 11 5.2.4 Minimum Inside Diameter 11 5.3 Deflection Resistance . 11 5.4 Leakage at Solvent
17、 Cemented Joints 11 5.5 Flattening . 11 5.6 Impact Resistance . 12 Annex A OUT OF ROUNDNESS GAUGES AND GO/NO-GO GAUGES 14 TC 2-2013 Page ii 2013 National Electrical Manufacturers Association TABLES Page Table 3-1 Sizes and Dimensions of EPC . 6 Table 3-2 Dimensions of Integral Belled Ends 7 Table 4-
18、1 Load for Deflection Resistance 9 Table 4-2 Load for Impact Resistance . Error! Bookmark not defined. Table A-1 Out of Roundness (Ovality) Gauges for EPC-40 and EPC-80 13 Table A-2 Go/No-Go Gauges for EPC-40 and EPC-8 .14 TC 2-2013 Page iii 2013 National Electrical Manufacturers Association FOREWOR
19、D The purpose of this publication for electrical polyvinyl chloride (PVC) conduit (EPC) for above-ground and below-ground use is: a) To list dimensions and other significant requirements. b) To set forth some of the properties of these products and to assist in selecting and obtaining the proper pro
20、duct for a particular need. User needs have been considered throughout the development and revision of this standard. The Polymer Raceway Products Section of NEMA, through its members, has worked (and continues to work) closely with such organizations as the American Society for Testing and Material
21、s, the Plastics Pipe Institute, Plastic Pipe and Fittings Association, appropriate government agencies, Underwriters Laboratories, Inc., and others in the periodic review and revision of these standards for any changes necessary to keep them up-to-date with advancing technology. Proposed or recommen
22、ded revisions should be submitted to: Senior Technical Director, Operations National Electrical Manufacturers Association 1300 North 17th Street, Suite 900 Rosslyn, Virginia 22209-3801 NEMA TC 2-2013 revises and supersedes the NEMA Standards Publication for Electrical Plastic Tubing (EPT) and Condui
23、t (EPC-40 and EPC-80), NEMA TC 2-2003. This publication was developed by the Polymer Raceway Products Section. Section approval of the standard does not necessarily imply that all section members voted for its approval or participated in its development. The following member companies of the section
24、 contributed to this revision of TC 2: Anamet Eletrical, Inc. Mattoon, IL Atkore AFC Cable Systems New Bedford, MA Atkore Allied Tube and Conduit Harvey, IL Champion Fiberglass, Inc. Spring, TX FRE Composites Inc. St. Andr-dArgenteuil, PQ, Canada Hubbell Incorporated Shelton, CT IPEX Electrical Inc.
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NEMATC22013ELECTRICALPOLYVINYLCHLORIDEPVCCONDUITPDF