NAVY UFGS-07 61 15 00 20-2011 ALUMINUM STANDING SEAM ROOFING《铝站缝屋面》.pdf
《NAVY UFGS-07 61 15 00 20-2011 ALUMINUM STANDING SEAM ROOFING《铝站缝屋面》.pdf》由会员分享,可在线阅读,更多相关《NAVY UFGS-07 61 15 00 20-2011 ALUMINUM STANDING SEAM ROOFING《铝站缝屋面》.pdf(25页珍藏版)》请在麦多课文档分享上搜索。
1、*USACE / NAVFAC / AFCESA / NASA UFGS-07 61 15.00 20 (May 2011)-Preparing Activity: NAVFAC SupersedingUFGS-07 61 15.00 20 (August 2008)UFGS-07 61 15.00 20 (April 2006)UFGS-07612N (September 1999)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated April 2011*SECTION TABL
2、E OF CONTENTSDIVISION 07 - THERMAL AND MOISTURE PROTECTIONSECTION 07 61 15.00 20ALUMINUM STANDING SEAM ROOFING05/11PART 1 GENERAL1.1 REFERENCES1.2 DEFINITIONS1.2.1 Field-Formed Seam1.2.2 Snap Together Seam1.2.3 Pre-Formed1.2.4 Field-Formed1.2.5 Roofing System1.3 SYSTEM DESCRIPTION1.3.1 Design Requir
3、ements1.3.2 Performance Requirements1.3.2.1 Wind Loads1.3.2.2 Resistance to Water Infiltration1.3.2.3 Thermal Movement1.3.2.4 Deflection1.3.2.5 Structural Performance1.4 SUBMITTALS1.5 LOAD CALCULATIONS1.6 QUALITY ASSURANCE1.6.1 Preroofing Conference1.6.2 Manufacturers Technical Representative1.6.3 Q
4、ualification of Installer1.6.4 Single Source1.6.5 Manufacturer1.7 DELIVERY, STORAGE, AND HANDLING1.7.1 Delivery1.7.2 Handling1.7.3 Storage1.8 WarrantyPART 2 PRODUCTS2.1 ROOFING PANELSSECTION 07 61 15.00 20 Page 1Provided by IHSNot for ResaleNo reproduction or networking permitted without license fro
5、m IHS-,-,-2.1.1 Material2.1.1.1 Thickness2.1.1.2 Finish2.1.1.3 Texture2.1.1.4 Color2.1.1.5 Configuration2.1.1.6 Prefinished Coating System2.2 ATTACHMENT CLIPS2.3 ACCESSORIES2.3.1 Closures2.3.1.1 Ridge Closure2.3.1.2 Rib Closure2.3.2 Fasteners2.3.2.1 Screws2.3.2.2 Bolts2.3.2.3 Automatic End-Welded St
6、uds2.3.2.4 Explosive Driven Fasteners2.3.2.5 Rivets2.3.3 Sealant2.3.4 Sealant Tape2.4 UNDERLAYMENT FOR WOOD SUBSTRATES2.5 LABORATORY TESTS FOR PANEL FINISH2.5.1 Salt Spray Test2.5.2 Formability Test2.5.3 Accelerated Weathering Test2.5.4 Chalking Resistance2.5.5 Abrasion Resistance Test for Color Coa
7、ting2.5.6 Humidity Test2.5.7 Fire Hazard2.5.8 Gloss2.5.9 Glare Resistance2.6 LINER PANELSPART 3 EXECUTION3.1 EXAMINATION3.2 PROTECTION OF DISSIMILAR METALS3.2.1 Contact with Masonry3.2.2 Contact with Wood3.3 INSTALLATION3.3.1 Roof Panels3.3.2 Flashings3.3.3 Flashing Fasteners3.3.4 Closure/Closure St
8、rips3.4 CLEANING3.5 MANUFACTURERS FIELD INSPECTION3.6 COMPLETED WORK3.7 INFORMATION CARD3.8 SCHEDULE3.9 FORM ONE- End of Section Table of Contents -SECTION 07 61 15.00 20 Page 2Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-*USACE / NAVFAC / AFCESA
9、/ NASA UFGS-07 61 15.00 20 (May 2011)-Preparing Activity: NAVFAC SupersedingUFGS-07 61 15.00 20 (August 2008)UFGS-07 61 15.00 20 (April 2006)UFGS-07612N (September 1999)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated April 2011*SECTION 07 61 15.00 20ALUMINUM STANDI
10、NG SEAM ROOFING05/11*NOTE: This guide specification covers the requirements for aluminum standing seam roofing.Use of electronic communication is encouraged.Adhere to UFC 1-300-02 Unified Facilities Guide Specifications (UFGS) Format Standard when editing this guide specification or preparing new pr
11、oject specification sections. Edit this guide specification for project specific requirements by adding, deleting, or revising text. For bracketed items, choose applicable items(s) or insert appropriate information. Brackets are used in the text to indicate designer choices or locations where text m
12、ust be supplied by the designer.Comments, suggestions and recommended changes for this guide specification are welcome and should be submitted as a Criteria Change Request (CCR).*NOTE: On the drawings, show:1. Design loads.2. Roof slope (minimum one in 24 1/2 inch per foot).3. Line(s) of fixity.4. S
13、upporting structural framework.5. Track spacing and attachment details, when applicable.6. Attachment clip spacing (list capacity of each type in spec).7. Flashing support and fastening spacing.SECTION 07 61 15.00 20 Page 3Provided by IHSNot for ResaleNo reproduction or networking permitted without
14、license from IHS-,-,-8. Roof venting. (Pay particular attention to preventing infiltration of wind-driven rain).9. Sealant and closure locations.10. Locations for dissimilar metal protection.11. Details of accessories such as ladders, walkways, antenna mounts, guy wire fastening, ventilation equipme
15、nt and lighting.12. Details of flashing at all roof penetrations.*NOTE: When designing standing seam roofs, consider:1. Consult with manufacturers early in design stage to obtain current design manuals and structural information regarding roof attachments. Early contact will reduce need for correcti
16、ons and changes during review process and construction phase.2. Calculate wind uplift forces in accordance with UFC 1-200-01, “General Building Requirements“.3. NAVFAC minimum guidelines are one in 24 1/2 inch per foot for roof slopes. Provide greater slope if possible. In renovation of existing bui
17、ldings, adequate slope must often be obtained by imaginative solutions. Sleepers and stub walls have been successfully used, but attachment and structural stability of these must be assured. In some existing structures it will be difficult to design strong connections to structural system, or modifi
18、cations to existing structural shimming system will be necessary to resist wind forces adequately.4. It will be necessary to diagram a number of attachment clips for varying roof conditions. Each type should be individually designated on the drawings with spacing shown. Spacing will be a function of
19、 allowable panel span and holding capability assumed for the clip(s). Minimum holding force for each type should be specified as subparagraphs under paragraph entitled “Attachment Clips.“ Assure that fasteners used to attach clips to structure develop full capacity of clip. Check existing structures
20、 to assure that the forces can be resisted by existing structural system. Make provisions for thermal expansion of roof structure.5. Flashing presents a particular design problem in preventing wind and water infiltration. High winds create stresses in flashing which must be resisted by careful detai
21、ling of attachment.While standing seam roofing presents continuous, SECTION 07 61 15.00 20 Page 4Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-sealed surface to the elements, flashing transitions are often the cause of serious problems. Overhangs,
22、especially, are susceptible to high wind forces and attachment should be at much closer spacing than usual. Copious use of sealants and closure pieces molded to conform to roof panels is imperative.6. Building may require equipment such as antennae, ladders, or lighting installed on roof. Access to
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYUFGS07611500202011ALUMINUMSTANDINGSEAMROOFING 铝站缝 屋面 PDF

链接地址:http://www.mydoc123.com/p-984731.html