NAVY UFGS-07 60 00-2008 FLASHING AND SHEET METAL《遮雨板和金属薄板》.pdf
《NAVY UFGS-07 60 00-2008 FLASHING AND SHEET METAL《遮雨板和金属薄板》.pdf》由会员分享,可在线阅读,更多相关《NAVY UFGS-07 60 00-2008 FLASHING AND SHEET METAL《遮雨板和金属薄板》.pdf(31页珍藏版)》请在麦多课文档分享上搜索。
1、*USACE / NAVFAC / AFCESA / NASA UFGS-07 60 00 (August 2008)-Preparing Activity: NAVFAC SupersedingUFGS-07 60 00 (January 2007)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated July 2008*SECTION TABLE OF CONTENTSDIVISION 07 - THERMAL AND MOISTURE PROTECTIONSECTION 07
2、60 00FLASHING AND SHEET METAL08/08PART 1 GENERAL1.1 REFERENCES1.2 General Requirements1.3 SUBMITTALS1.4 DELIVERY, HANDLING, AND STORAGEPART 2 PRODUCTS2.1 MATERIALS2.1.1 Exposed Sheet Metal Items2.1.2 Drainage2.1.3 Copper, Sheet and Strip2.1.4 Lead-Coated Copper Sheet2.1.5 Lead Sheet2.1.6 Steel Sheet
3、, Zinc-Coated (Galvanized)2.1.6.1 Finish2.1.7 Zinc Sheet and Strip2.1.8 Stainless Steel2.1.9 Terne-Coated Steel2.1.10 Aluminum Alloy Sheet and Plate2.1.10.1 Alclad2.1.10.2 Finish2.1.11 Aluminum Alloy, Extruded Bars, Rods, Shapes, and Tubes2.1.12 Solder2.1.13 Polyvinyl Chloride Reglet2.1.14 Bituminou
4、s Plastic Cement2.1.15 Roofing Felt2.1.16 Asphalt Primer2.1.17 FastenersPART 3 EXECUTION3.1 INSTALLATION3.1.1 Metal Roofing3.1.1.1 Flat Copper, Zinc, Terne-coated Steel RoofingSECTION 07 60 00 Page 1Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-3.1
5、.1.2 Standing-seam Method3.1.1.3 Flat-seam Method3.1.2 Workmanship3.1.3 Nailing3.1.4 Cleats3.1.5 Bolts, Rivets, and Screws3.1.6 Seams3.1.6.1 Flat-lock Seams3.1.6.2 Lap Seams3.1.6.3 Loose-Lock Expansion Seams3.1.6.4 Standing Seams3.1.6.5 Flat Seams3.1.7 Soldering3.1.7.1 Edges3.1.8 Welding and Mechani
6、cal Fastening3.1.8.1 Welding of Aluminum3.1.8.2 Mechanical Fastening of Aluminum3.1.9 Protection from Contact with Dissimilar Materials3.1.9.1 Copper or Copper-bearing Alloys3.1.9.2 Aluminum3.1.9.3 Metal Surfaces3.1.9.4 Wood or Other Absorptive Materials3.1.10 Expansion and Contraction3.1.11 Base Fl
7、ashing3.1.12 Counterflashing3.1.13 Metal Reglets3.1.13.1 Caulked Reglets3.1.13.2 Friction Reglets3.1.14 Polyvinyl Chloride Reglets Temporary Construction Installation3.1.15 Gravel Stops and Fascias3.1.15.1 Edge Strip3.1.15.2 Joints3.1.16 Metal Drip Edge3.1.17 Gutters3.1.18 Downspouts3.1.18.1 Termina
8、tions3.1.19 Flashing for Roof Drains3.1.20 Scuppers3.1.21 Conductor Heads3.1.22 Splash Pans3.1.23 Open Valley Flashing3.1.24 Eave Flashing3.1.25 Sheet Metal Covering on Flat, Sloped, or Curved Surfaces3.1.26 Expansion Joints3.1.26.1 Roof Expansion Joints3.1.26.2 Floor and Wall Expansion Joints3.1.27
9、 Flashing at Roof Penetrations and Equipment Supports3.1.28 Single Pipe Vents3.1.29 Stepped Flashing3.1.30 Copings3.2 PAINTING3.2.1 Aluminum Surfaces3.3 CLEANING3.4 REPAIRS TO FINISH3.5 FIELD QUALITY CONTROL3.5.1 Procedure- End of Section Table of Contents -SECTION 07 60 00 Page 2Provided by IHSNot
10、for ResaleNo reproduction or networking permitted without license from IHS-,-,-SECTION 07 60 00 Page 3Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-*USACE / NAVFAC / AFCESA / NASA UFGS-07 60 00 (August 2008)-Preparing Activity: NAVFAC SupersedingUF
11、GS-07 60 00 (January 2007)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated July 2008*SECTION 07 60 00FLASHING AND SHEET METAL08/08*NOTE: This guide specification covers the requirements for flashing and sheet metal work including gutters and downspouts, scuppers, sp
12、lash pans, and sheet metal roofing.Edit this guide specification for project specific requirements by adding, deleting, or revising text. For bracketed items, choose applicable items(s) or insert appropriate information.Remove information and requirements not required in respective project, whether
13、or not brackets are present.Comments and suggestions on this guide specification are welcome and should be directed to the technical proponent of the specification. A listing of technical proponents, including their organization designation and telephone number, is on the Internet.Recommended change
14、s to a UFGS should be submitted as a Criteria Change Request (CCR).*NOTE: The specified sheet metal roofing is the type commonly used for on-site fabrication which does not include factory fabricated or preformed metal roofing. Preformed and Standing Seam metal roofing is covered in other Division 7
15、 sections. Gravity roof ventilators, roof scuttles, louvers, and similar items are not included. This guide specification requires extensive editing when used with single ply roof systems in order to assure compatibility.*NOTE: Details of sheet metalwork will be shown on project drawings in accordan
16、ce with the appropriate details in the Architectural Sheet Metal Manual of SECTION 07 60 00 Page 4Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-the Sheet Metal and Air Conditioning Contractors National Association (SMACNA).Coordinate specifications
17、 with the drawings so that drawing details and SMACNA Arch. Manual requirements do not conflict or repeat. Delete references to SMACNA Arch. Manual when requirements are detailed in the drawings.*NOTE: On the drawings, show:1. Base, counter open valley, and eave flashing2. Roof drain flashing3. Expa
18、nsion joints - (The drawings should contain interior and exterior details of building expansion joints at walls, ceiling, floors, roof, and parapets. Provide isometric detailing for expansion joint intersections.)4. Sheet metal roofing; extent and slope.5. Gutters and downspouts.*PART 1 GENERAL*NOTE
19、: Sheet metal color will be long lasting such as anodized aluminum, or baked enamel, and will not be painted in the field. This does not preclude the use of natural materials like copper or aluminum when that is the choice of the designer. Avoid use of copper where drainage from the copper will pass
20、 over exposed masonry, stonework, or other metal surfaces.Galvanized steel will not be permitted as an option to other metals specified. Galvanized steel may be specified for temporary structures or where it may be satisfactory due to climatic conditions. Where galvanized steel is specified, changes
21、 will be made to the text as follows:Paragraph REFERENCES:ASTM A 526 (1990) Steel Sheet, Zinc-Coated(Galvanized) by the Hot-Dip Process,Commercial QualityParagraph MATERIALS Add: Galvanized Steel: ASTM A 526, Coating G90.Paragraph PROTECTION OF ALUMINUM: Require SECTION 07 60 00 Page 5Provided by IH
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYUFGS0760002008FLASHINGANDSHEETMETAL 遮雨板 金属薄板 PDF

链接地址:http://www.mydoc123.com/p-984729.html