1、MILIT. RY SPECIFIC, MI L-D-81227B E5 Decarber 1976 SUPERSEDING MIL-D-81227A 24 June 1971 TION DETECTOR KIT, WATER, AUTOMOTIVE - AVIATION FUEL This specification is approved for use by all Departments and Agencies of the Department of Defense. 1. SCOPE P - v 1.1 Scope. This specification covers two t
2、ypes of electrically operated free water kits, designated as Model MK II. 1.2 Classification. The detector kits shall be of the following types as specified (see 6.1 and 6.2). Type I - Water detector, Mk II with viewer and pads. Type III - Water detector, Mk II with viewer and battery case. Designat
3、ed as KMU-352/E. 2. APPLICABLE DOCUMENTS 2.1 The following documents of the issue in effect on date of invitation for bids or request for proposal, form a part of this specification to the extent spec- fied herein. SPECIFIC ATIONS FEDERAL W-C-596 - Connector, Plug, Electrical, Connector, Receptacle,
4、 Electrical QQ-C-320 - Chromium Plating (Electrodeposited) QQ-N-290 - Nickel Plating (Electrodeposited) QQ-P-416 - Plating, Cadmium (Electrodeposited) PPP-B-585 - Box, Wood, Wirebound Beneficial comments (fecommendations, additions, deletions) and any pertinent data which may be of use in improving
5、this document should be addressed to: Engineering Specifications and Standards Department (Code 93), Naval AU Engi- neering Center, Lakehurst, NJ 08733, by using the self-addressed Standardizatiom Document improvement Proposal (DD Form 1426) appearing at the end of this document or by letter. FSC 66
6、40 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-D-BL227B 66 = 7779706 OL429O 7 - MIL-D-81227B FEDERAL (Continued) PPP-B-601 - Box, Wood, Cleated-Plywood PPP-B-621 - Box, Wood, Nailed and Lock-Corner PPP-B-636 - Box, Shipping, Fiberboard MILITA
7、RY MIbE-5558 - Enamel, Wrinkle Finish, for Aircraft Use MIL-M-7298 - Manual, Technical, Commercial Equipment MIL-S-7742 - Screw Threads; Standard, Optimum Selected Series, General Specification for MIL-S-8516 - Sealing Compound, Polysulfide Rubber Electric Connectors and Electric Systems, Chemically
8、 Cured MIGA-8625 - Anodic Coatings, for Aluminum and Aluminum Alloys MIL-L-10547 - Liners, Case, and Sheet, Overwrap; Water-Vaporproof or Waterproof, Flexible MIL-D-81248 - Detector Pad, Free Water MIL-S-81282 - Standard, Free Water Detector STANDARDS FEDERAL FED-STD-595 - Colors MILITARY MIL-STD-10
9、5 - Sampling Procedures and Tables for Inspection by Attributes MIL-STD-129 - Marking for Shipment and Storage MIL-STD-130 - Identification Marking of U. S. Military Property MS35489 - Grommet, Rubber, Hot Oil and Coolant Resistant PUB LICA TION S U.S. AIR FORCE TECHNICAL ORDER T, O. 42B-1.1 - Quali
10、ty Control of Fuels and Lubricants 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-D-81227B (Copies of specification, standards, drawings, and publications, required by suppliers in connection with specific procurement functions should be obtai
11、ned from the procuring activity or as directed by the contracting officer. ) 2.2 Other publications. The following documents form a part of this specification to the extent specified herein. Unless otherwise indicated, the issue in effect on the date of invitation for bids or request for proposal sh
12、all apply. UNIFORM CLASSIFICATION COMMITTEE Uniform Freight Classification 4 (Application for copies should be addressed to Uniform Classification Com- mittee, Room 202 Union Station, 516 W. Jackson Blvd., Chicago, Illinois 60606. ) 3. REQUIREMENTS . 3.1 First article. The water detector kit furnish
13、ed under this speci- fication shall be a product which has been inspected and has passed the first article inspection specified herein (see 4.3). 3.2 Materials. Materials shall conform to the applicable specifica- tions as listed or required herein. Materials which are not covered by specifications,
14、 or which are not specifically described herein, shall be of the best quality, of the lightest practical weight and suitable for the purpose intended. 3.2.1 Metals. Metals for all component parts shall be in accordance with those specified in Figure 1. 3.2.2 Fungusproof materials. Materials which ar
15、e nutrients for fungi shall not be used in the detector kit where it is practical to avoid them. Where used and not hermetically sealed, they shall be treated with a fungicidal agent acceptable to the procuring activity. 3.2.3 Electrical. 3.2.3.1 Power requirement. The Mk II Free Water Detector shal
16、l be designed to operate on 120 volts DC, as indicated in Figure 1, or 120 volts A. C., 60 hertz. Y 3.2.3.2 Wiring. External and internal wiring shall be in accordance with Figures 1 and 3. The internal wiring shall be neat and accomplished in such a manner that individual wires may be easily traced
17、. 3.2.4 Threads. Screw threads O. 060 inch in diameter or larger shall be in accordance with MIL-S-7742. 3.2.5 Weight. The weight of the completely assembled Water Detector Kit shall not exceed 5 pounds for Type I and 15 pounds for Type III. This weight does not include batteries. 3 Provided by IHSN
18、ot for ResaleNo reproduction or networking permitted without license from IHS-,-,-3.20 6.1 Aluminum alloy protection. Unless otherwise specified, all alum- inum alloy parts shallbe coated with an anodic film, dyed matte black, in accordance with Class 2, MIL-A-8625. 3.2.6.2 Exterior finish. Where ap
19、plicable, the exterior finish shall be in accordance with MIL-E-5558, Type I or II, using Federal Standard No. 595, Color 17038. 3.2. 6.3 Interior finish. Unless otherwise specified, the interior requires only the coating specified in 3.2.6.1, A 3.3 Identification of product. A nameplate, in accorda
20、nce with Figure 2 shall be securely attached to the exterior of the case, and shall be legibly and durably marked with the NSN (see 6.5) and information as follows: for Type I - Viewer Kit, Free Water Detector, Model No. MK II for Type III - Viewer, Free Water Detector, Model No. KMU-352/E I 3.4 Ser
21、vice data package. A service data package consisting of materials and manuals, as described below, shall be furnished, in an envelope, with each unit. Detector pads (3.4.2) while not physically in the envelope shall be con- sidered part of the service data package. 3.4.1 Standards. A total of 3 stan
22、dards conforming to MIL-S-81282, shall be provided with each unit. The standards shall be included in the envelope, or optionally, one may be attached to the unit as specified in 3.5.2.1. Instructions for attaching the standard to the unit shall be included. The standards shall be supplied to the co
23、ntractor as Government furnished material (see 6.4). 3.4.2 Detector pads. Each Type I service data package shall contain 500 free water detector pads (47 mm) conforming to MIL-D-81248. The pads shall be supplied to the contractor as Government furnished material (see 6.4). 3.4.3 Technical manual. Ea
24、ch data package shall contain two copies of an approved technical manual (see 4.3.1.1). The manual shall be prepared in accord- ance with MIL-M-7298 and shail include a list of component parts; complete instruc- tions for installation, operation, placement and replacement of batteries for Type III,
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILD81227B1976DETECTORKITWATERAUTOMOTIVEAVIATIONFUEL 水力 驱动 自动 航空 燃料 探测 工具 PDF

链接地址:http://www.mydoc123.com/p-978370.html