《NAVY A-A-50580-1997 TRUCK TANK SEWAGE OR WASTE COLLECTION COMMERCIAL 4 BY 2 [Superseded NAVY MIL-T-23435 F CANC NOTICE 1 NAVY MIL-T-23435 F NAVY MIL-T-23435 E NAVY MIL-T-23435 D NAT-.pdf》由会员分享,可在线阅读,更多相关《NAVY A-A-50580-1997 TRUCK TANK SEWAGE OR WASTE COLLECTION COMMERCIAL 4 BY 2 [Superseded NAVY MIL-T-23435 F CANC NOTICE 1 NAVY MIL-T-23435 F NAVY MIL-T-23435 E NAVY MIL-T-23435 D NAT-.pdf(16页珍藏版)》请在麦多课文档分享上搜索。
1、 A-A-50580 9999974 0174148 791 INCH-POUND A-A-5 05 8 O ADd 7.1997 SUPERSEDING 13 May 1991 MIL-T-2343 5F COMMERCIAL ITEM DESCRIPTION TRUCK, TANK: SEWAGE OR WASTE COLLECTION, COMMERCIAL 4 BY 2 The General Services Administration has authorized the use of this commercial item description for all Federa
2、l agencies. 1. SCOPE. This commercial item description (CID) covers commercial sewage or waste collection trucks intended for collection of waste or raw unscreened sewage by suction. 2. CLASSIFICATION. Trucks shall be of the following types as specified (see 7.2): Type I - 1,300-gallon (4 921 litre
3、(L) minimum to 1,500-gallon (5 678 L) capacity pressure vessel. Type II - 2,000-gallon (7 570 L) minimum capacity pressure vessel. 3. SALIENT CHARACTERISTICS. 3.1 Design. The truck shall consist of a pressure vessel, a power-takeoff-driven vacuum pump, complete with all necessary piping, valves, con
4、trols, and safety devices. The sewage collection components shall be mounted on a four-wheel, two-rear-wheel-drive, diesel-engine-driven chassis with conventional cab. The unit shall be Department of Transportation (DOT) certified for hazardous, flammable, corrosive, class B poison or combination th
5、ereof 3.2 Standard commercial product. The sewage collection truck shall, as a minimum, be in accordance with the requirements of this CID and shall be the manufacturers standard Beneficial comments, recommendations, additions, deletions, clarifications, etc. and any data which may improve this docu
6、ment should be sent to: Commanding Officer (Code lSSl), Naval Construction Battalion Center, 1000 23rd Avenue, Port Hueneme, CA 93043-4301, by using the Standardization Document Improvement Proposal (DD Form 1426) appearing at the end of this document or by letter. AMSC NIA FSC 2320 Provided by IHSN
7、ot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-50580 9999974 0174149 628 I A-A-50580 commercial product. Additional or better fatures which are not specifically prohibited by this CID but which are a part of the mandacturers standard commercial product, shall b
8、e included in the sewage collection truck being furnished. A standard commercial product is a product which has been sold or is being sold or is being currently offered for sale on the commercial market through advertisements or manufacturers catalogs, or brochures, and represents the latest product
9、ion model. 3.2.1 Coolant system. The unit shall be equipped with a heavy duty cooling system capable of maintaining a coolant temperature below the boiling point of the coolant when the truck is operated in ambient air of not less than 125 degrees Fahrenheit (OF) (52 degrees Celsius (“C) at an altit
10、ude of 10,000 feet (3 048 metre (m) with a load equal to the gross vehicle weight rating. The coolant system shall include a deaeration system and a surge tank or a coolant recovery reservoir of not less than a 2-quart (2 L) capacity. 3.2.1.1 Alarms and indicators. A high coolant temperature or low
11、coolant level alarm buzzer and red indicator warning light shall be provided on the cab dash instrument panel. 3.2.1.2 Coolant temperature control. The unit shall be provided with a thermostatic coolant temperature control. The thermostat shall control both the flow of coolant through the radiator a
12、nd the radiator shutters. 3.3 Drain pluas. Permanent magnet type drain plugs shall be provided for the manual transmission and the rear axle. 3.4 Towing: devices. Not less than two hooks or loops, mounted to the fiame or to rigid members which are attached to the fiame, shaii be furnished on the fio
13、nt of the truck for towing purposes. 3.5 Radio interference suppression. The vehicle shall be suppressed to limit electromagnetic radiation in accordance with SAE J55 1. Any mounted equipment shall be suppressed to the same level. 3.6 Splash mar an average water flow rate of 8 Provided by IHSNot for
14、 ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-50580 9779974 Olt74156 868 = Type I II A-A-505 80 Minimum Maximum 1,300 (4 921) 2,000 (7 570) 1,500 (5 678) 2,300 (8 706) not less than 200 gallons per minute (13 Us) with a vertical lift of 18 feet (5 486 mm); and an av
15、erage water flow rate of not less than 20 gallons (1.3 L/s) per minute with a vertical lift of 25 feet (7 620 mm). Evacuation of sewage from the tank shall be at an average flow rate of not less than 250 gallons per minute (16 Lis) when using compressed air fiom the discharge side of the vacuum pump
16、. All sewage inlet and outlet piping shall be capable of passing solids up to 2-inch (5 1 mm) sphere size. Float shutoff valves of the sewage tank shall be capable of closing the vacuum line, when under suction fiom the vacuum pump, without transmitting any liquid to the vacuum pump when either the
17、sewage tank or surge tank is Ned with water. The sewage tank valve and surge tank shall be capable of preventing sewage from entering the vacuum pump suction line when the truck is loading waste caustics and detergents, to within an allowable leakage tolerance of 1/50 of 1 percent of the sewage tank
18、 capacity collected into the tank. 3.23.2 Sewage tank. The sewage collection tank shall meet the capacities listed in table II. The sewage tank shail be the horizontal type, in accordance with ASME Boiler and Pressure Vessel Code, section Vm, for a design pressure of not less than 40 pounds per squa
19、re inch (276 kilopascals (Wa) and for full vacuum. ASME Boiler and Pressure Vessel Code, section Vm, certification shall be fimished by an authorized Boiler and Vessel Inspector. The tank shall be fabricated from not less than 0.25-inch (6 mm), high tensile, low alloy steel; or from mild steel or co
20、pper bearing steel of a thickness that produces equivalent strength, with welded smooth skin construction. The tank heads shall be substantially dished, flanged, and reinforced to provide structural strength of hydraulic pressure from either direction. The length of the tank shall be such as to give
21、 load distribution proportional to the rated capacity of the fiont and rear axles of the truck chassis. Outlet opening shall be at the rear bottom of the tank located to provide complete tank drainage. Full length longitudinal Z-type, box type, or V-type tank fiame members shall be furnished. TABLE
22、II. Tank capacity in dlons (litre). 3.23.3 Baflles. The tank shall be provided with baftles, the number of which shall be such that the linear distance between any two adjacent bafes, or between the tank head and the bafEle nearest to it, shall be not greater than 50 inches (1 270 mm). Baftles shall
23、 be reinforced and provided with half round openings at top and bottom. Each bafle shall be provided with an opening not less than 16 inches (406 mm) in diameter. The bafle area shall be not less than 80 percent of the cross-sectional area of the tank. 3.23.4 Access openings. An access opening shall
24、 be provided in the top of the tank to provide access to the tank float shutoff valve. In addition, a washout opening shall be provided on the top of the tank. Each opening shall be not less than 16 inches (406 mm) in diameter, or an oval with axis of not less than 12 inches by 16 inches (305 mm by
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYAA505801997TRUCKTANKSEWAGEORWASTECOLLECTIONCOMMERCIAL4BY2SUPERSEDEDNAVYMILT23435FCANCNOTICE1NAVYMILT23435FNAVYMILT23435ENAVYMILT23435DNATPDF

链接地址:http://www.mydoc123.com/p-976295.html