NAVISTAR MPAPS L-6610-2017 Thermal Insulation.pdf
《NAVISTAR MPAPS L-6610-2017 Thermal Insulation.pdf》由会员分享,可在线阅读,更多相关《NAVISTAR MPAPS L-6610-2017 Thermal Insulation.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、This document is restricted and may not be sent outside Navistar, Inc. or reproduced without permission from Corporate Technical Standards. Suppliers are required to assume all patent liability. 2017 by Navistar, Inc. SEPTEMBER 2017 Page 1 of 9 NAVISTAR, INC. Material, Parts, and Process Specificati
2、ons (MPAPS) NUMBER: MPAPS L-6610 Former Designation: TMS-6610 TITLE: Thermal Insulation CURRENT REV No.: 1709 DATE: Sep. 2017 WRITTEN/EDITED BY: D. Baker APPROVED BY: R. Goluch SUPERSEDES: Rev. 1412 Dec. 2014 PRINTED COPIES OF THIS DOCUMENT MUST BE VERIFIED FOR CURRENT REVISION This specification ma
3、y involve hazardous materials, equipment, and procedures. This specification does not purport to address all of the safety issues associated with its use. The user is responsible to consult appropriate safety and health practices and to determine the applicability of regulatory limits prior to use.
4、1.0 APPLICATION This specification outlines the requirements for interior cab insulation, which is used as a thermal barrier to improve the heating and cooling characteristics of the cab. Several types of thermal insulation/heat shields are included in this specification. If a specific insulation ma
5、terial is required, it shall be described on the print. Note: This specification is for thermal insulators and heat shields. Although some of these materials may have acoustic benefits (see note on acoustic insulation below), materials with specific acoustic requirements may be found in these specif
6、ications: Cab floor and dash insulation is covered in MPAPS L-6606, urethane foam insulation in MPAPS L-6505, molded fiberglass engine tunnel cover and external cab insulators in MPAPS L-6609, and other acoustic insulation in MPAPS L-6612. 2.0 SCOPE This specification covers the general requirements
7、, property and performance requirements, quality, qualification, source approval, and quality control for cab insulators and composite heat shields. NOTE: For existing engineering drawings/blueprints which reference this specification but do not specify a Type (I, II, III, IV, V, VI, VII, VIII, IX,
8、X, or XI), Type I 2.1 Restricted Chemical Substances Effective January 1, 2007, all product supplied to the requirements of this specification must comply with the requirements of the MPAPS B-50 specification. 3.0 REFERENCE DOCUMENTS Unless otherwise specified the latest issue of all referenced stan
9、dards shall apply. The following Specifications, Standards, and Regulations are referenced in this specification. Quality System Standard ISO 9001 or TS-16949 CFR Title 29, Part 1910 ASTM D 903 NAVISTAR Supplier Packing and Shipping Std. D-13 ASTM B 117 ASTM D 3330 NAVISTAR Eng. Design Std. A-16 AST
10、M C 177 ASTM D 3574 NAVISTAR MPAPS P-9544 ASTM C 518 FMVSS-302 NAVISTAR MPAPS K-6929 ASTM D 751 NAVISTAR MPAPS L-6505 ASTM D 1056 NAVISTAR MPAPS L-6609 AATCC Method 30 NAVISTAR MPAPS L-6606 NAVISTAR MPAPS C-10 NAVISTAR MPAPS L-6612 NAVISTAR MPAPS A-37 NAVISTAR MPAPS P-9543 NAVISTAR MPAPS B-50 NAVIST
11、AR MPAPS B-50 NAVISTAR MPAPS C-10 NUMBER: MPAPS L-6610 TITLE: Thermal Insulation REVISION: 1709 This document is restricted and may not be sent outside Navistar, Inc. or reproduced without permission from Corporate Technical Standards. Suppliers are required to assume all patent liability. 2017 by N
12、avistar, Inc. SEPTEMBER 2017 Page 2 of 9 4.0 GENERAL REQUIREMENTS 4.1 Product Type Descriptions and Specific Requirements 4.1.1 Type I: Insulation that consists of polyester spun fibers. The cab insulator shall have a nominal thickness of 2.5 cm (1 in) except for designated areas on the drawing wher
13、e the thickness is increased to afford better insulation properties. (Thickness of some part families may vary depending upon die plate requirements.) 4.1.2 Type II: Insulation that consists of an open cell, urethane foam. The foam shall be uniform in thickness, will be free from thin spots or voids
14、 and shall show no sign of surface shedding or crumbling. 4.1.3 Type III: Polyethylene closed-cell foam with a pressure-sensitive adhesive that can be easily repositioned during assembly. The foam shall be uniform in thickness, will be free from thin spots or voids and shall show no sign of surface
15、shedding or crumbling. This type of insulation is typically used in the dash, door and floor areas where additional thermal insulation is desired but no acoustic benefit is needed. The closed nature of this product is particularly beneficial in areas that may be wet or exposed to the environment. 4.
16、1.4 Type IV: Foam, glass fiber or polyester fiber covered on one or both sides with a 1-mil metalized polyester facing film or encapsulated within a fibrous scrim covering. Foam, if applicable, shall be uniform in thickness, will be free from thin spots or voids and shall show no sign of surface she
17、dding or crumbling. These products are typically used for under-hood thermal insulation and may be fastened with pressure sensitive adhesive (PSA) film with release liner, liquid adhesive or by mechanical fasteners. This product may need to have edges sealed or wrapped, depending on the application,
18、 and shall be so designated on the engineering print. 4.1.5 Type V: Composite insulation having aluminum foil on one or both sides with multiple layers of polyester or glass fibers sandwiched between additional layers of foil. Material will be manufactured such that sharp edges are not exposed. Thic
19、kness will be uniform and show no evidence of delamination. These products are typically used for under-hood thermal insulation where temperatures may reach up to 400 F. They may be fastened with PSA film with release liner, liquid adhesive or by mechanical fasteners. This product may need to have e
20、dges sealed or wrapped, depending on the application, and shall be so designated on the engineering print. Specific composite constructions shall be indicated on the engineering print or as a letter designation in this specification. 4.1.6 Type VI: Embossed aluminum or stainless steel heat shields m
21、ade with multiple layers that can be flat stamped or formed. Material will be manufactured such that sharp edges are not exposed. Thickness will be uniform although variance due to forming will be accepted. Ceramic, glass or polyester fiber insulation may be, optionally, used to insulate and separat
22、e the various layers. These materials are typically used to shield areas from localized hot spots that can reach temperatures up to 550C, by reflecting and laterally conducting the heat outward over a relatively large surface area (note: aluminum is a better heat shield material but would have a low
23、er temperature limit and more subject to physical damage; stainless steel should be used when appropriate). They are typically attached by mechanical means or by spot welds. This product may need to have edges sealed or wrapped, depending on the application and handling concerns. Specific composite
24、constructions shall be indicated on the engineering print or as a letter designation in this specification. 4.1.7 Type VII A tri-layer composite consisting of ” polyurethane foam faced on each side with Aluminized Polyester Facing, a ” air gap achieved with Foam Tape spaced throughout the part, and
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVISTARMPAPSL66102017THERMALINSULATIONPDF