NASA UFGS-23 82 23 00 40-2011 UNIT VENTILATORS《装置通风设备》.pdf
《NASA UFGS-23 82 23 00 40-2011 UNIT VENTILATORS《装置通风设备》.pdf》由会员分享,可在线阅读,更多相关《NASA UFGS-23 82 23 00 40-2011 UNIT VENTILATORS《装置通风设备》.pdf(18页珍藏版)》请在麦多课文档分享上搜索。
1、*USACE / NAVFAC / AFCESA / NASA UFGS-23 82 23.00 40 (February 2011)-Preparing Activity: NASA SupersedingUFGS-23 82 23 (November 2008)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated January 2011*SECTION TABLE OF CONTENTSDIVISION 23 - HEATING, VENTILATING, AND AIR CO
2、NDITIONINGSECTION 23 82 23.00 40UNIT VENTILATORS02/11PART 1 GENERAL1.1 REFERENCES1.2 SUBMITTALS1.3 MECHANICAL PROVISIONS1.4 GENERAL REQUIREMENTSPART 2 PRODUCTS2.1 MANUFACTURED UNITS2.1.1 Gas Unit Heaters (GUH)2.1.1.1 Type2.1.1.2 Casing2.1.1.3 Heat Exchangers2.1.1.4 Burners2.1.1.5 Fans2.1.1.6 Motors2
3、.1.1.7 Controls2.1.2 Propeller Unit Heaters-Hot Water and Steam (PUH)2.1.2.1 Type2.1.2.2 Vertical Discharge Units2.1.2.3 Horizontal Discharge Units2.1.2.4 Heating Element2.1.2.5 Casings2.1.2.6 Propellers and Motors2.1.2.7 Sound Rating2.1.2.8 Control2.1.3 Cabinet Unit Heaters (CUH)2.1.3.1 Type2.1.3.2
4、 Heating Element2.1.3.3 Fan and Drive Assembly2.1.3.4 Filters2.1.3.5 Enclosures2.1.3.6 Insulation2.1.3.7 Control Cycle2.1.4 Unit Ventilators (UV)SECTION 23 82 23.00 40 Page 1Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-2.1.4.1 Type2.1.4.2 Heating
5、Element2.1.4.3 Fan and Drive Assembly2.1.4.4 Filters2.1.4.5 Dampers2.1.4.6 Enclosures2.1.4.7 Wall Sleeve2.1.4.8 Thermal and Acoustic Insulation2.1.4.9 Control Cycle2.1.4.10 Fresh Air IntakesPART 3 EXECUTION3.1 INSTALLATION3.1.1 Equipment3.1.2 Gas Piping3.1.3 Combustion Air3.1.4 Location3.1.5 Venting
6、3.2 FIELD QUALITY CONTROL- End of Section Table of Contents -SECTION 23 82 23.00 40 Page 2Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-*USACE / NAVFAC / AFCESA / NASA UFGS-23 82 23.00 40 (February 2011)-Preparing Activity: NASA SupersedingUFGS-23
7、82 23 (November 2008)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated January 2011*SECTION 23 82 23.00 40UNIT VENTILATORS02/11*NOTE: This guide specification covers the requirements for unit heaters and ventilators.Edit this guide specification for project specific
8、requirements by adding, deleting, or revising text. For bracketed items, choose applicable items(s) or insert appropriate information.Remove information and requirements not required in respective project, whether or not brackets are present.Comments, suggestions and recommended changes for this gui
9、de specification are welcome and should be submitted as a Criteria Change Request (CCR).*PART 1 GENERAL1.1 REFERENCES*NOTE: This paragraph is used to list the publications cited in the text of the guide specification. The publications are referred to in the text by basic designation only and listed
10、in this paragraph by organization, designation, date, and title.Use the Reference Wizards Check Reference feature when you add a RID outside of the Sections Reference Article to automatically place the reference in the Reference Article. Also use the Reference Wizards Check Reference feature to upda
11、te the issue dates.References not used in the text are automatically deleted from this section of the project specification when you choose to reconcile references in the publish print process.*SECTION 23 82 23.00 40 Page 3Provided by IHSNot for ResaleNo reproduction or networking permitted without
12、license from IHS-,-,-The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.ACOUSTICAL SOCIETY OF AMERICA (ASA)ASA S12.11/Part 1 (2003; R 2008) Acoustics-Measurement of Noise and Vibrati
13、on of Small Air-Moving Devices, Part 1: Airborne Noise EmissionASA S12.11/Part 2 (2003; R 2008) Acoustics-Measurement of Noise and Vibration of Small Air-Moving Devices, Part 2: Structure-borne VibrationASA S12.30 (1990; R 2002) Standard Guidelines for the Use of Sound Power Standards and for the Pr
14、eparation of Noise Test CodesASA S12.53/1 (1999; R 2004) Acoustics- Determination of Sound Power Levels of Noise Sources - Engineering Methods for Small, Movable Sources in Reverberant Fields - Part1: Comparison Method for Hard-Walled Test RoomsASA S12.53/2 (1999; R 2009) Acoustics- Determination of
15、 Sound Power Levels of Noise Sources Using Sound Pressure - Engineering Methods for Small, Movable Sources in Reverberant Fields - Part2: Methods for Special Reverberation Test RoomsALUMINUM ASSOCIATION (AA)AA DAF-45 (2003; Reaffirmed 2009) Designation System for Aluminum FinishesAMERICAN NATIONAL S
16、TANDARDS INSTITUTE (ANSI)ANSI Z83.8/CSA 2.6 (2009) American National Standard/CSA Standard for Gas Unit Heater, Gas Packaged Heaters, Gas Utility Heaters and Gas-Fired Duct FurnacesASTM INTERNATIONAL (ASTM)ASTM A 568/A 568M (2009a) Standard Specifications for Steel, Sheet, Carbon, Structural, and Hi
17、gh-Strength, Low-Alloy, Hot-Rolled and Cold-Rolled, General Requirements forASTM A 653/A 653M (2009a) Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip ProcessASTM F 1040 (1987; R 2007) Standard Specification for Filter Units, Ai
18、r Conditioning, Viscous - SECTION 23 82 23.00 40 Page 4Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Impingement and Dry Types, ReplaceableINTERNATIONAL CODE COUNCIL (ICC)ICC IFGC (2009) International Fuel Gas CodeICC IMC (2009) International Mecha
19、nical CodeNATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION (NEMA)NEMA MG 1 (2009) Motors and GeneratorsNATIONAL FIRE PROTECTION ASSOCIATION (NFPA)NFPA 54 (2009; TIA 10-3) National Fuel Gas CodeNFPA 70 (2011) National Electrical CodeNFPA 90A (2009; Errata 09-1) Standard for the Installation of Air Condi
20、tioning and Ventilating SystemsU.S. DEPARTMENT OF DEFENSE (DOD)DOD-G-24508 (1998; Rev A; Am 4) Grease, High Performance, Multipurpose (Metric)1.2 SUBMITTALS*NOTE: Review Submittal Description (SD) definitions in Section 01 33 00 SUBMITTAL PROCEDURES and edit the following list to reflect only the su
21、bmittals required for the project. Keep submittals to the minimum required for adequate quality control.A “G” following a submittal item indicates that the submittal requires Government approval. Some submittals are already marked with a “G”. Only delete an existing “G” if the submittal item is not
22、complex and can be reviewed through the Contractors Quality Control system. Only add a “G” if the submittal is sufficiently important or complex in context of the project.For submittals requiring Government approval on Army projects, use a code of up to three characters within the submittal tags fol
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NASAUFGS23822300402011UNITVENTILATORS 装置 通风设备 PDF

链接地址:http://www.mydoc123.com/p-836595.html