ARMY UFGS-07 72 00-2009 ROOF VENTILATORS GRAVITY-TYPE《重力式屋顶通风设备》.pdf
《ARMY UFGS-07 72 00-2009 ROOF VENTILATORS GRAVITY-TYPE《重力式屋顶通风设备》.pdf》由会员分享,可在线阅读,更多相关《ARMY UFGS-07 72 00-2009 ROOF VENTILATORS GRAVITY-TYPE《重力式屋顶通风设备》.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、*USACE / NAVFAC / AFCESA / NASA UFGS-07 72 00 (August 2009)-Preparing Activity: USACE SupersedingUFGS-07 72 00 (April 2006)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated July 2009*SECTION 07 72 00ROOF VENTILATORS, GRAVITY-TYPE08/09*NOTE: This guide specification c
2、overs the requirements for gravity-type roof ventilators including stationary, turbine, and ridge types.Edit this guide specification for project specific requirements by adding, deleting, or revising text. For bracketed items, choose applicable items(s) or insert appropriate information.Remove info
3、rmation and requirements not required in respective project, whether or not brackets are present.Comments and suggestions on this guide specification are welcome and should be directed to the technical proponent of the specification. A listing of technical proponents, including their organization de
4、signation and telephone number, is on the Internet.Recommended changes to a UFGS should be submitted as a Criteria Change Request (CCR).*PART 1 GENERAL1.1 REFERENCES*NOTE: This paragraph is used to list the publications cited in the text of the guide specification. The publications are referred to i
5、n the text by basic designation only and listed in this paragraph by organization, designation, date, and title.Use the Reference Wizards Check Reference feature when you add a RID outside of the Sections Reference Article to automatically place the reference in the Reference Article. Also use the R
6、eference Wizards Check Reference feature to update the issue dates.SECTION 07 72 00 Page 1Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-References not used in the text will automatically be deleted from this section of the project specification whe
7、n you choose to reconcile references in the publish print process.*The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.AMERICAN SOCIETY OF CIVIL ENGINEERS (ASCE)ASCE 7-05 (2006; Errat
8、a 2007) Minimum Design Loads for Buildings and Other StructuresASTM INTERNATIONAL (ASTM)ASTM A 653/A 653M (2009) Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip ProcessASTM B 209 (2007) Standard Specification for Aluminum and A
9、luminum-Alloy Sheet and PlateASTM B 209M (2007) Standard Specification for Aluminum and Aluminum-Alloy Sheet and Plate (Metric)ASTM B 221 (2008) Standard Specification for Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and TubesASTM B 221M (2007) Standard Specification for Aluminum
10、 and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes (Metric)SHEET METAL AND AIR CONDITIONING CONTRACTORS NATIONAL ASSOCIATION (SMACNA)SMACNA 1793 (2006) Architectural Sheet Metal Manual, Sixth Edition, Second Printing1.2 DESIGN REQUIREMENTS*NOTE: To determine the ventilator size and p
11、erformance requirements, the latest ventilator manufacturers recommendations should be used, including latest ASHRAE Handbook “Fundamentals“ published by the American Society of Heating, Refrigerating and Air-Conditioning Engineers.*Design ventilators for use with the specific type of project roofin
12、g system, and to provide uniform and continuous air flow. Ventilator design shall provide protection against rain and snow, and shall be provided with a continuous weep along the bottom of both sides of wind band. Units shall be self-cleaning by the action of the elements, and shall have provisions
13、SECTION 07 72 00 Page 2Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-for carrying water and normal wind-transported soil matter to the outside. Design units for windspeeds of not less than 36 _ m/second 80 _ mph in accordance with ASCE 7-05. Ventil
14、ators shall be free of internal obstructions or moving parts which will require maintenance, and shall be complete with type of mounting indicated on drawings.1.3 SUBMITTALS*NOTE: Review submittal description (SD) definitions in Section 01 33 00 SUBMITTAL PROCEDURES and edit the following list to re
15、flect only the submittals required for the project. Submittals should be kept to the minimum required for adequate quality control.A “G” following a submittal item indicates that the submittal requires Government approval. Some submittals are already marked with a “G”. Only delete an existing “G” if
16、 the submittal item is not complex and can be reviewed through the Contractors Quality Control system. Only add a “G” if the submittal is sufficiently important or complex in context of the project.For submittals requiring Government approval on Army projects, a code of up to three characters within
17、 the submittal tags may be used following the “G“ designation to indicate the approving authority. Codes for Army projects using the Resident Management System (RMS) are: “AE“ for Architect-Engineer; “DO“ for District Office (Engineering Division or other organization in the District Office); “AO“ f
18、or Area Office; “RO“ for Resident Office; and “PO“ for Project Office. Codes following the “G“ typically are not used for Navy, Air Force, and NASA projects.Choose the first bracketed item for Navy, Air Force and NASA projects, or choose the second bracketed item for Army projects.*Government approv
19、al is required for submittals with a “G“ designation; submittals not having a “G“ designation are for Contractor Quality Control approval. information only. When used, a designation following the “G“ designation identifies the office that will review the submittal for the Government. Submit the foll
20、owing in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:SD-02 Shop DrawingsRoof Ventilators; G; G, _Dimensioned drawings indicating location of each type of ventilator including details of construction, gauges of metal, and methods of operation of dampers and controls.SECTION 07 72 00 Page 3P
21、rovided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-1.4 QUALITY ASSURANCEManufacturer shall specialize in design and manufacture of the type of roof ventilators specified in this section, and shall have a minimum of _ years of documented successful experi
22、ence. Provide a ventilator installer experienced in the installation of ventilator types specified.1.5 DELIVERY, STORAGE, AND HANDLINGRoof ventilators shall be cartoned or crated prior to shipment. Protect ventilators from moisture and damage. Remove damaged items from the site.PART 2 PRODUCTS2.1 MA
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYUFGS0772002009ROOFVENTILATORSGRAVITYTYPE 重力 屋顶 通风设备 PDF

链接地址:http://www.mydoc123.com/p-449575.html