ARI 1060-2005 PERFORMANCE RATING OF AIR-TO-AIR HEAT EXCHANGERS FOR ENERGY RECOVERY VENTILATION EQUIPMENT《能量恢复通风设备空气对空气热交换器作业评定》.pdf
《ARI 1060-2005 PERFORMANCE RATING OF AIR-TO-AIR HEAT EXCHANGERS FOR ENERGY RECOVERY VENTILATION EQUIPMENT《能量恢复通风设备空气对空气热交换器作业评定》.pdf》由会员分享,可在线阅读,更多相关《ARI 1060-2005 PERFORMANCE RATING OF AIR-TO-AIR HEAT EXCHANGERS FOR ENERGY RECOVERY VENTILATION EQUIPMENT《能量恢复通风设备空气对空气热交换器作业评定》.pdf(11页珍藏版)》请在麦多课文档分享上搜索。
1、 2005 STANDARD for 4100 N. FAIRFAX DR., SUITE 200 ARLINGTON, VIRGINIA 22203 PERFORMANCE RATING OF AIR-TO- AIR HEAT EXCHANGERS FOR ENERGY RECOVERY VENTILATION EQUIPMENT Standard 1060 Copyright Air-Conditioning and Refrigeration Institute Provided by IHS under license with ARI Not for ResaleNo reprodu
2、ction or networking permitted without license from IHS-,-,-IMPORTANT SAFETY DISCLAIMER ARI does not set safety standards and does not certify or guarantee the safety of any products, components or systems designed, tested, rated, installed or operated in accordance with this standard/guideline. It i
3、s strongly recommended that products be designed, constructed, assembled, installed and operated in accordance with nationally recognized safety standards and code requirements appropriate for products covered by this standard/guideline. ARI uses its best efforts to develop standards/guidelines empl
4、oying state-of-the-art and accepted industry practices. ARI does not certify or guarantee that any tests conducted under its standards/guidelines will be non-hazardous or free from risk. ARI CERTIFICATION PROGRAM PROVISIONS Scope of the Certification Program The certification program includes Air-to
5、-Air Heat Exchangers for use in Air-to-Air Energy Recovery Ventilation Equipment, rated at or above 50 scfm but below or equal to 5,000 scfm at ARI Standard Rating Conditions. In addition, Air-to-Air Heat Exchangers for use in Energy Recovery Ventilation Equipment rated above 5,000 scfm are included
6、 if the participants basic model group(s) for those models include at least one model rated at or above 50 scfm but below or equal to 5,000 scfm. This certification program does not include heat exchangers joined by circulated heat transfer medium (run-around loop). Certified Ratings The following c
7、ertification program ratings are verified by test: 1. Airflow, scfm 2. Pressure Drop, in H2O 3. Sensible Effectiveness (at 100% and 75% rated airflow for heating and cooling conditions) 4. Latent Effectiveness (at 100% and 75% rated airflow for heating and cooling conditions) 5. Total Effectiveness
8、(at 100% and 75% rated airflow for heating and cooling conditions) 6. Exhaust Air Transfer Ratio, Outdoor Air Correction Factor, and Purge Angle or Setting (if applicable) at 0.00 in H2O and two or more pressure differentials 7. Tilt Angle, o, (at heating and cooling conditions, if applicable) Note:
9、 This standard supersedes ARI Standard 1060-2001. Price $10.00 (M) $20.00 (NM) Copyright 2005, by Air-Conditioning and Refrigeration Institute Printed in U.S.A. United States Patent and Trademark Office Registered Copyright Air-Conditioning and Refrigeration Institute Provided by IHS under license w
10、ith ARI Not for ResaleNo reproduction or networking permitted without license from IHS-,-,-TABLE OF CONTENTS SECTION PAGE Section 1. Purpose1 Section 2. Scope.1 Section 3. Definitions 1 Section 4. Test Requirements 4 Section 5. Rating Requirements.5 Section 6. Minimum Data Requirements for Published
11、 Ratings .6 Section 7. Marking and Nameplate Data .7 Section 8. Conformance Conditions 7 TABLES Table 1. Standard Rating Conditions 4 APPENDICES Appendix A. References - Normative 8 Appendix B. References - Informative.8 Appendix C. Calculation of Effectiveness - Normative.9Copyright Air-Conditionin
12、g and Refrigeration Institute Provided by IHS under license with ARI Not for ResaleNo reproduction or networking permitted without license from IHS-,-,-ARI STANDARD 1060-2005 2 PERFORMANCE RATING OF AIR-TO-AIR HEAT EXCHANGERS FOR ENERGY RECOVERY VENTILATION EQUIPMENT Section 1. Purpose 1.1 Purpose.
13、The purpose of this standard is to establish for Air-to-Air Heat Exchangers intended for use in Air-to-Air Energy Recovery Ventilation Equipment: definitions; test requirements; rating requirements; minimum data requirements for Published Ratings; marking and nameplate data; and conformance conditio
14、ns. 1.1.1 Intent. This standard is intended for the guidance of the industry, including manufacturers, designers, installers, contractors and users. 1.1.2 Review and Amendment. This standard is subject to review and amendment as technology advances. Section 2. Scope 2.1 Scope. This standard applies
15、to factory-made Air-to-Air Heat Exchangers for use in Air-to-Air Energy Recovery Ventilation Equipment as defined in Section 3. 2.2 Exclusions. This standard does not apply to the rating and testing of heat exchangers joined by circulated heat transfer medium (run-around loop). A run-around loop emp
16、loys liquid-containing coils connected in a closed loop and placed in each of two or more airstreams. Section 3. Definitions All terms in this document shall follow the standard industry definitions in the current edition of ASHRAE Terminology of Heating, Ventilation, Air Conditioning and Refrigerat
17、ion and ASHRAE Standard 84, unless otherwise defined in this section. 3.1 Air-to- Air Energy Recovery Ventilation Equipment (AAERVE). Energy recovery components and packaged energy recovery ventilation units which employ Air-to-Air Heat Exchangers to recover energy from exhaust air for the purpose o
18、f pre-conditioning outdoor air prior to supplying the conditioned air to the space, either directly or as part of an air-conditioning (to include air heating, air cooling, air circulating, air cleaning, humidifying and dehumidifying) system. 3.2 Air-to-Air Heat Exchanger. A device that transfers hea
19、t from an exhaust airstream to a separated supply airstream. Air-to-Air Heat Exchangers are also referred to as energy recovery components. 3.2.1 Heat Pipe Heat Exchanger. A device employing tubes charged with a fluid for the purpose of transferring sensible energy from one airstream to another. Hea
20、t transfer takes place through the vaporization of the fluid exposed to the warmer airstream and condensation of the fluid in the cooler airstream. 3.2.2 Plate Heat Exchanger. A device for the purpose of transferring energy (sensible or total) from one airstream to another with no moving parts. This
21、 exchanger may incorporate parallel, cross or counter flow construction or a combination of these to achieve the energy transfer. 3.2.3 Rotary Heat Exchanger. A device incorporating a rotating cylinder or wheel for the purpose of transferring energy (sensible or total) from one airstream to the othe
22、r. It incorporates heat transfer material, a drive mechanism, a casing or frame, and includes any seals which are provided to retard the bypassing and leakage of air from one airstream to the other. 3.3 Effectiveness. The measured energy recovery Effectiveness not adjusted to account for that portio
23、n of the psychrometric change in the Leaving Supply Airflow that is the result of leakage of Entering Exhaust Airflow rather than exchange of heat or moisture between the airstreams. The equation for determining Effectiveness is given in Appendix C. Copyright Air-Conditioning and Refrigeration Insti
24、tute Provided by IHS under license with ARI Not for ResaleNo reproduction or networking permitted without license from IHS-,-,-ARI STANDARD 1060-2005 3 3.4 Exhaust Airflow. Airflow leaving the conditioned space. 3.4.1 Entering Exhaust Airflow (Return Air). The exhaust airstream before passing throug
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARI10602005PERFORMANCERATINGOFAIRTOAIRHEATEXCHANGERSFORENERGYRECOVERYVENTILATIONEQUIPMENT 能量 恢复 通风设备

链接地址:http://www.mydoc123.com/p-429420.html