NASA UFGS-23 41 13 00 40-2010 PANEL FILTERS《仪表板滤波器》.pdf
《NASA UFGS-23 41 13 00 40-2010 PANEL FILTERS《仪表板滤波器》.pdf》由会员分享,可在线阅读,更多相关《NASA UFGS-23 41 13 00 40-2010 PANEL FILTERS《仪表板滤波器》.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、*USACE / NAVFAC / AFCESA / NASA UFGS-23 41 13.00 40 (May 2010)-Preparing Activity: NASA SupersedingUFGS-23 41 13 (August 2008)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated April 2010*SECTION TABLE OF CONTENTSDIVISION 23 - HEATING, VENTILATING, AND AIR CONDITIONIN
2、GSECTION 23 41 13.00 40PANEL FILTERS05/10PART 1 GENERAL1.1 SYSTEM DESCRIPTION1.2 REFERENCES1.3 SUBMITTALS1.4 GENERAL REQUIREMENTSPART 2 PRODUCTS2.1 FILTERS2.1.1 Filters, Disposable Type2.1.2 Filters, Cleanable Type2.1.3 Filters, Replaceable Type2.1.4 Filters, Automatic Type2.1.5 Filters, High-Effici
3、ency Particulate Air (HEPA)2.2 FILTER GAGES AND MANOMETERSPART 3 EXECUTION3.1 FILTER INSTALLATION3.2 HOLDING FRAME INSTALLATION3.3 TESTS- End of Section Table of Contents -SECTION 23 41 13.00 40 Page 1Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-*
4、USACE / NAVFAC / AFCESA / NASA UFGS-23 41 13.00 40 (May 2010)-Preparing Activity: NASA SupersedingUFGS-23 41 13 (August 2008)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated April 2010*SECTION 23 41 13.00 40PANEL FILTERS05/10*NOTE: This specification covers the requ
5、irements for basic types of filters for use with air handling equipment.Edit this guide specification for project specific requirements by adding, deleting, or revising text. For bracketed items, choose applicable items(s) or insert appropriate information.Remove information and requirements not req
6、uired in respective project, whether or not brackets are present.Comments and suggestions on this guide specification are welcome and should be directed to the technical proponent of the specification. A listing of technical proponents, including their organization designation and telephone number,
7、is on the Internet.Recommended changes to a UFGS should be submitted as a Criteria Change Request (CCR).*PART 1 GENERAL*NOTE: Specify any required extra media, filters, and adhesive. Indicate overall physical features, dimensions, ratings, service requirements, and equipment weights on drawings.*1.1
8、 SYSTEM DESCRIPTIONProvide panel filters system complete with all components and accessory equipment as specified in this section.*NOTE: If Section 23 00 00 AIR SUPPLY, DISTRIBUTION, AND EXHAUST SYSTEMS is not included in the project specification, insert applicable requirements SECTION 23 41 13.00
9、40 Page 2Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-therefrom and delete the first paragraph.*Section 23 00 00 AIR SUPPLY, DISTRIBUTION, AND EXHAUST SYSTEMS applies to work specified in this section. Submit Manufacturers Catalog Data, including
10、physical characteristics and performance data for panel filters system.1.2 REFERENCES*NOTE: This paragraph is used to list the publications cited in the text of the guide specification. The publications are referred to in the text by basic designation only and listed in this paragraph by organizatio
11、n, designation, date, and title.Use the Reference Wizards Check Reference feature when you add a RID outside of the Sections Reference Article to automatically place the reference in the Reference Article. Also use the Reference Wizards Check Reference feature to update the issue dates.References no
12、t used in the text will automatically be deleted from this section of the project specification when you choose to reconcile references in the publish print process.*The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the
13、text by the basic designation only.AMERICAN SOCIETY OF HEATING, REFRIGERATING AND AIR-CONDITIONING ENGINEERS (ASHRAE)ASHRAE 52.1 (1992; Interpretation 1 2007) Gravimetric and Dust-Spot Procedures for Testing Air-Cleaning Devices Used in General Ventilation for Removing Particulate MatterASME INTERNA
14、TIONAL (ASME)ASME AG 1 (2009) Code on Nuclear Air and Gas TreatmentASTM INTERNATIONAL (ASTM)ASTM A 526/A 526M (1990) Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) by the Hot-Dip Process, Commercial QualityASTM A 653/A 653M (2009a) Standard Specification for Steel Sheet, Zinc-Coate
15、d (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip ProcessSECTION 23 41 13.00 40 Page 3Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-ASTM D 92 (2005a) Standard Test Method for Flash and Fire Points by Cleveland Open Cup TesterAS
16、TM E 84 (2009c) Standard Test Method for Surface Burning Characteristics of Building MaterialsNATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY (NIST)NIST PS 1 (2007) Construction and Industrial PlywoodU.S. DEPARTMENT OF DEFENSE (DOD)MIL-F-29177 (Rev A; CANC Notice 1) Filter, Air-Extended Area, Initial
17、 InstallationMIL-STD-282 (1995; Basic, Notice 4) Filter Units, Protective Clothing, Gas-Mask Components and Related Products: Performance-Test MethodsU.S. GENERAL SERVICES ADMINISTRATION (GSA)FED-STD-209 (Rev C) Clean Room and Work Station Requirements, Controlled EnvironmentUNDERWRITERS LABORATORIE
18、S (UL)UL 586 (2009) Standard for High-Efficiency Particulate, Air Filter UnitsUL 723 (2008) Standard for Test for Surface Burning Characteristics of Building MaterialsUL 900 (2004; R 1995 thru 2009) Standard for Air Filter Units1.3 SUBMITTALS*NOTE: Review Submittal Description (SD) definitions in Se
19、ction 01 33 00 SUBMITTAL PROCEDURES and edit the following list to reflect only the submittals required for the project. Submittals should be kept to the minimum required for adequate quality control.A “G” following a submittal item indicates that the submittal requires Government approval. Some sub
20、mittals are already marked with a “G”. Only delete an existing “G” if the submittal item is not complex and can be reviewed through the Contractors Quality Control system. Only add a “G” if the submittal is sufficiently important or complex in context of the project.For submittals requiring Governme
21、nt approval on Army projects, a code of up to three characters within SECTION 23 41 13.00 40 Page 4Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-the submittal tags may be used following the “G“ designation to indicate the approving authority. Codes
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NASAUFGS23411300402010PANELFILTERS 仪表板 滤波器 PDF

链接地址:http://www.mydoc123.com/p-836590.html