1、 MSS SP-125-2010 Gray Iron and Ductile Iron In-Line, Spring-Loaded, Center-Guided Check Valves Standard Practice Developed and Approved by the Manufacturers Standardization Society of the Valve and Fittings Industry, Inc. 127 Park Street, NE Vienna, Virginia 22180 Phone: (703) 281-6613 Fax: (703) 28
2、1-6671 e-mail: infomss-hq.org www.mss-hq.org MSS STANDARD PRACTICE SP-125i This MSS Standard Practice was developed under the consensus of the MSS Technical Committee 106 and the MSS Coordinating Committee. The content of this Standard Practice is the result of the efforts of competent and concerned
3、 volunteers to provide an effective, clear, and non-exclusive specification that will benefit the industry as a whole. This MSS Standard Practice is intended as a basis for common practice by the manufacturer, the user, and the general public. The existence of an MSS Standard Practice does not in it
4、self preclude the manufacture, sale, or use of products not conforming to the Standard Practice. Mandatory conformance is established only by reference in a code, specification, sales contract, or public law, as applicable. “Other standards documents referred to herein are identified by the date of
5、issue that was applicable to this Standard Practice at the date of issue of this Standard Practice. See Annex B. This Standard Practice shall remain silent on the applicability of those other standards of prior or subsequent dates of issue even though applicable provisions may not have changed. Refe
6、rences contained herein which are bibliographic in nature are noted as supplemental in the text.” Unless otherwise specifically noted in this MSS SP, any standard referred to herein is identified by the date of issue that was applicable to the referenced standard(s) at the date of issue of this MSS
7、Standard Practice (See Annex B). In this Standard Practice all notes, annexes, tables, and figures are construed to be essential to the understanding of the message of the standard, and are considered part of the text unless noted as “supplemental“. All appendices, if included, that appear in this d
8、ocument are construed as “supplemental“. Supplemental information does not include mandatory requirements for this Standard Practice. Substantive changes in this 2010 edition are “flagged” by parallel bars as shown on the margins of this paragraph. The specific detail of the change may be determined
9、 by comparing the material flagged with that in the previous edition. U.S. customary units in this Standard Practice are the standard; metric (SI) units are for reference only. Any part of this Standard Practice may be quoted. Credit lines should read Extracted from MSS SP-125-2010 with permission o
10、f the publisher, Manufacturers Standardization Society of the Valves and Fittings Industry, Inc. Reproduction is prohibited under copyright convention unless written permission is granted by Manufacturers Standardization Society of the Valve and Fittings Industry Inc. Originally Approved: August 200
11、0 Copyright , 2000, 2010 by Manufacturers Standardization Society of the Valve and Fittings Industry, Inc. Printed in U.S.A. MSS STANDARD PRACTICE SP-125ii TABLE OF CONTENTS SECTION PAGE 1 SCOPE 1 2 VALVE STYLES AND CLASSES . 1 3 PRESSURE AND TEMPERATURE RATINGS 1 4 MATERIALS . 1 5 DESIGN . 2 6 WORK
12、MANSHIP 3 7 TESTS 4 8 MARKING . 4 9 PAINTING . 4 TABLE 1 CWP Ratings at 150F (65C), Non-Shock 2 2 Disc and Seat Materials 2 3 Face-to-Face Dimensions of Wafer-Style Check Valves . 3 4 Face-to-Face Dimensions of Compact Wafer-Style Check Valves . 3 5 Face-to-Face Dimensions of Globe-Style Check Valve
13、s . 3 6 Minimum Duration of Tests . 4 FIGURE A1 Wafer-Style 5 A2 Compact Wafer-Style . 5 A3 Flanged Globe-Style 5 A4 Wafer-Style 6 A5 Compact Wafer-Style . 6 A6 Flanged Globe-Style 6 ANNEX A Valve Types - - Figures A1 through A6 . 5 B Referenced Standards and Applicable Dates . 7 MSS STANDARD PRACTI
14、CE SP-1251 1. SCOPE 1.1 This Standard Practice covers in-line, internally spring-loaded, center-guided check valves made of gray iron or ductile iron. These valves, having the feature of limiting fluid flow to one direction only, are intended for use with clean fluids (i.e. fluids that do not contai
15、n solids), including potable water, waterworks, and other industrial applications, in horizontal and vertical installations. 2. VALVE STYLES AND CLASSES 2.1 Valve styles The valve styles included in this Standard Practice are determined by the configuration of the body. 2.1.1 Wafer Wafer-style check
16、 valves have a single flange body with an outside diameter equal to that of the mating pipe flanges. The valve body may be designed with holes passing through the body (see Figure A1) or with threaded lugs. The size range for wafer-style check valves is NPS 2-10 (DN 50-250). 2.1.2 Compact Wafer Comp
17、act wafer-style valves have a reduced outside body diameter, or slots, to provide bolt clearance for long bolts or studs (see Figure A2). The size range for compact wafer-style check valves is NPS 2-10 (DN 50-250). 2.1.3 Globe Globe-style check valves have two integrally cast flanges and a rounded-c
18、enter body section to provide increased flow area around the valve disc (see Figure A3). The size range of globe-style check valves is NPS 2-42 (DN 50-1050). 2.2 Flange Classes Valve end connections shall conform to the following requirements. 2.2.1 Wafer-style valves shall have bolt holes or thread
19、ed holes in accordance with ASME B16.1 for gray iron, Class 125 or 250 and in accordance with ASME B16.42 for ductile iron, Class 150 or 300. 2.2.2 Compact wafer-style valves shall have a reduced body diameter to accommodate flange bolts in accordance with ASME B16.1 for gray iron, Class 125 or 250
20、or ASME B16.42 for ductile iron, Class 150 or 300. 2.2.3 Globe-style flange dimensions shall be in accordance with ASME B16.1 for gray iron, Class 125 or 250 and in accordance with ASME B16.42 for ductile iron, Class 150 or 300. For sizes above NPS 24 (DN 600), ductile iron flange dimensions shall b
21、e in accordance with ASME B16.1. 2.2.5 Gaskets Full face or ring gaskets are required between the valve ends and the mating pipeline flanges to obtain a pressure tight joint. 3. PRESSURE AND TEMPERATURE RATINGS 3.1 The CWP ratings for various valve flange classes are specified in Table 1. 3.2 The ch
22、eck valves in this Standard Practice are intended for use in clean fluids with a temperature between 33F and 150F (1C and 65C). For elevated temperature installations, the manufacturer should be consulted. 4. MATERIALS 4.1 General This Standard Practice is intended to cover the minimum mechanical an
23、d chemical requirements for the items depicted in Figures A4, A5, and A6. GRAY IRON AND DUCTILE IRON, IN-LINE, SPRING-LOADED, CENTER-GUIDED CHECK VALVES MSS STANDARD PRACTICE SP-1252 TABLE 1 CWP Ratings at 150oF (65oC), Non-Shock FLANGE CLASS BODY MATERIAL SIZES CWP RATING ANDSEAT TEST PRESSURE SHEL
24、L TESTPRESSURE NPS DN PSI kPa PSI kPa 125 Gray Iron 2-12 50-300 200 1379 300 2068 14-42 350-1050 150 1034 225 1551 150 Ductile Iron 2-12 50-300 300 2068 450 3102 14-42 350-1050 250 1724 375 2586 250 Gray Iron 2-12 50-300 400 2758 600 4136 14-42 350-1050 300 2068 450 3102 300 Ductile Iron 2-12 50-300
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- MSSSP1252010GREYIRONANDDUCTILEIRONINLINESPRINGLOADEDCENTERGUIDEDCHECKVALVES 弹簧 加载 中心 导向 嵌入式 灰铸铁 球墨铸铁

链接地址:http://www.mydoc123.com/p-822959.html