ITU-T S 15-1988 USE OF THE TELEX NETWORK FOR DATA TRANSMISSION AT 50 BAUDS《用户电报网在50Bd下供数据传输使用》.pdf
《ITU-T S 15-1988 USE OF THE TELEX NETWORK FOR DATA TRANSMISSION AT 50 BAUDS《用户电报网在50Bd下供数据传输使用》.pdf》由会员分享,可在线阅读,更多相关《ITU-T S 15-1988 USE OF THE TELEX NETWORK FOR DATA TRANSMISSION AT 50 BAUDS《用户电报网在50Bd下供数据传输使用》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、INTERNATIONAL TELECOMMUNICATION UNION)45G134 3 TELECOMMUNICATIONSTANDARDIZATION SECTOROF ITU4%,%2!0(9!,0(!“%4)#!,G0G04%,%2!0(G0G04%2-).!,%15)0-%.453%G0G0/ amended at Mar del Plata, 1968)The CCITT,considering(a) that the telex network is well adapted for the economical transmission of data at fairly
2、slow speeds, forthe equipment required for binary transmission of data by telex stations, over and above the normal equipment, isrelatively simple;(b) but that some limits have to be imposed on data transmission codes used in the telex network becauseof:- the need to make sure that telex calls will
3、not be abruptly released;- exaggerated distortion that may be introduced by amplitude-modulation voice-frequency telegraphsystems when an excessively long-duration start (condition A) modulation element appears in a signal;- the fact that in some networks there is regenerative repetition of start-st
4、op signals, which can be handledonly as if they were constructed like five-unit start-stop information signals;- the possibility that certain long-distance calls may be established over synchronous systems that canhandle only five-unit start-stop signals;(c) that the limitation due to regenerative r
5、epeaters and synchronous systems imposes the use of a five-unitstart-stop code for information, hence 1 of the Recommendation (the more general procedure) deals with datatransmission with a five-unit code on start-stop systems. But in certain circumstances alphabets with more than fiveunits can be u
6、sed for data transmission; hence 2 of the Recommendation,unanimously declares the following view:1 Data transmission with a five-unit code on start-stop systems1.1 Telex calls for data transmission may be set up in the international telex network, subject to the followingprovisions:1.2 The call shal
7、l be set up between the caller and the called subscriber in accordance with the procedurerecommended for the setting-up of a telex call and its supervision by exchange of answer-back codes(Recommendations F.60 1 and U.1 2).1.3 When one of the subscribers concerned wishes to introduce data transmissi
8、on equipment into the connection,he shall transmit the sequence SSSS (or ) of combination No. 19 from International Telegraph Alphabet No. 2(signal for transfer to data). Upon reception of this sequence of combinations, the data transmission or receptionequipment, as the case may be, shall be connec
9、ted to the line. This changeover to the data position may be effected:a) manually at both terminals;b) automatically at both terminals;c) manually at one terminal and automatically at the other.In order to avoid any misunderstanding between the stations concerned, the calling operator should first c
10、heck theequipment of the distant station (whether manual changeover or automatic changeover).2 Fascicle VII.1 - Rec. S.151.3.1 Manual changeover at both terminals1.3.1.1 Once the connection has been set up, the following procedure should be followed.1.3.1.2 The operator of the calling station sends
11、the sequence of four combinations No. 19. This sequence should notconnect the data equipment locally.1.3.1.3 Upon reception of the SSSS (or ) sequence, the operator of the called station likewise sends the sequenceof four combinations No. 19, and then connects his data equipment to the line.1.3.1.4
12、Upon reception of this answer sequence, the calling operator connects his data equipment to the line.1.3.2 Automatic changeover at both terminals1.3.2.1 Once the connection has been set up, the following procedure should be followed:1.3.2.2 The calling station sends the sequence of four combinations
13、 No. 19 and must connect its data equipment tothe line automatically within less than 500 milliseconds, starting from the end of transmission of the last signal of thissequence.1.3.2.3 Reception of the sequence at the other terminal of the connection connects the called station to the dataequipment
14、line automatically within less than 500 milliseconds, starting from the end of reception of the last signal ofthis sequence.1.3.2.4 The data transmission should not commence before the end of the 500-millisecond delay.1.3.3 Calling station with manual changeover and called station with automatic cha
15、ngeover1.3.3.1 Once the connection has been set up, the following procedure is followed:1.3.3.2 The operator of the calling station sends the sequence of four combinations No. 19, and then immediatelyconnects his data equipment to the line.1.3.3.3 Upon reception of the sequence of four combinations
16、No. 19 at the called station, the data equipment must beconnected to the line within less than 500 milliseconds, starting from the end of reception of this sequence.1.3.3.4 The data signals should not be transmitted before the end of the 500-millisecond delay.1.3.4 Calling station with automatic cha
17、ngeover and called station with manual changeover1.3.4.1 Once the connection has been set up, the following procedure should be followed:1.3.4.2 The calling station invites its called correspondent, by a brief preliminary message, to send the sequence offour combinations No. 19. This message must no
18、t include within itself the sequence of four combinations No. 19. If thecalling station is not equipped with a teleprinter attended by an operator, this preliminary message must be sentautomatically.1.3.4.3 The operator of the called station then sends the sequence of four combinations No. 19 and im
19、mediatelyconnects his data equipment to the line.1.3.4.4 Upon reception of this sequence at the calling station, connection of the data equipment to the line must beeffected within less than 500 milliseconds, starting from the end of reception of the last combination No. 19 of thesequence.1.3.4.5 Tr
20、ansmission of the data signals should not begin before the end of the 500-millisecond delay.Note - The arrangements envisaged throughout 1.3 above run counter to the inclusion of the sequence offour combinations No. 19 in the answer-back code of telex lines equipped with a simulator and at the same
21、time in theanswer-back of teleprinters equipped with an automatic device for changeover to data transmission. (This fact shouldbe borne in mind in the further study of this Recommendation.)Fascicle VII.1 - Rec. S.15 31.4 The sequence of four combinations No. 19 will make ineffective, where necessary
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ITUTS151988USEOFTHETELEXNETWORKFORDATATRANSMISSIONAT50BAUDS 用户 电报 50 BD 数据传输 使用 PDF

链接地址:http://www.mydoc123.com/p-803004.html