ITU-T L 108-2018 Optical fibre cable elements for microduct blowing-installation application (Study Group 15).pdf
《ITU-T L 108-2018 Optical fibre cable elements for microduct blowing-installation application (Study Group 15).pdf》由会员分享,可在线阅读,更多相关《ITU-T L 108-2018 Optical fibre cable elements for microduct blowing-installation application (Study Group 15).pdf(31页珍藏版)》请在麦多课文档分享上搜索。
1、 I n t e r n a t i o n a l T e l e c o m m u n i c a t i o n U n i o n ITU-T L.108 TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU (03/2018) SERIES L: ENVIRONMENT AND ICTS, CLIMATE CHANGE, E-WASTE, ENERGY EFFICIENCY; CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE P
2、LANT Optical fibre cables Cable structure and characteristics Optical fibre cable elements for microduct blowing-installation application Recommendation ITU-T L.108 ITU-T L-SERIES RECOMMENDATIONS ENVIRONMENT AND ICTS, CLIMATE CHANGE, E-WASTE, ENERGY EFFICIENCY; CONSTRUCTION, INSTALLATION AND PROTECT
3、ION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT OPTICAL FIBRE CABLES Cable structure and characteristics L.100L.124 Cable evaluation L.125L.149 Guidance and installation technique L.150L.199 OPTICAL INFRASTRUCTURES Infrastructure including node elements (except cables) L.200L.249 General aspects a
4、nd network design L.250L.299 MAINTENANCE AND OPERATION Optical fibre cable maintenance L.300L.329 Infrastructure maintenance L.330L.349 Operation support and infrastructure management L.350L.379 Disaster management L.380L.399 PASSIVE OPTICAL DEVICES L.400L.429 MARINIZED TERRESTRIAL CABLES L.430L.449
5、 For further details, please refer to the list of ITU-T Recommendations. Rec. ITU-T L.108 (03/2018) i Recommendation ITU-T L.108 Optical fibre cable elements for microduct blowing-installation application Summary Recommendation ITU-T L.108 (ex. L.79) describes the characteristics, construction and t
6、est methods for microduct fibre units and microduct cables that are used with the blowing installation technique. The cable characteristics required for a cable to perform appropriately are described. Also, a method is described for determining whether or not the cable has the required characteristi
7、cs. The required conditions may differ according to the installation environment; detailed test conditions must be agreed upon between a user and a manufacturer for the environment in which a cable is to be used. History Edition Recommendation Approval Study Group Unique ID* 1.0 ITU-T L.108/L.79 200
8、8-07-07 6 11.1002/1000/9429 2.0 ITU-T L.108 2018-03-16 15 11.1002/1000/13565 Keywords Blowing installation, fibre unit, microcable, microduct, optical fibre cable. _ * To access the Recommendation, type the URL http:/handle.itu.int/ in the address field of your web browser, followed by the Recommend
9、ations unique ID. For example, http:/handle.itu.int/11.1002/1000/11830-en. ii Rec. ITU-T L.108 (03/2018) FOREWORD The International Telecommunication Union (ITU) is the United Nations specialized agency in the field of telecommunications, information and communication technologies (ICTs). The ITU Te
10、lecommunication Standardization Sector (ITU-T) is a permanent organ of ITU. ITU-T is responsible for studying technical, operating and tariff questions and issuing Recommendations on them with a view to standardizing telecommunications on a worldwide basis. The World Telecommunication Standardizatio
11、n Assembly (WTSA), which meets every four years, establishes the topics for study by the ITU-T study groups which, in turn, produce Recommendations on these topics. The approval of ITU-T Recommendations is covered by the procedure laid down in WTSA Resolution 1. In some areas of information technolo
12、gy which fall within ITU-Ts purview, the necessary standards are prepared on a collaborative basis with ISO and IEC. NOTE In this Recommendation, the expression “Administration“ is used for conciseness to indicate both a telecommunication administration and a recognized operating agency. Compliance
13、with this Recommendation is voluntary. However, the Recommendation may contain certain mandatory provisions (to ensure, e.g., interoperability or applicability) and compliance with the Recommendation is achieved when all of these mandatory provisions are met. The words “shall“ or some other obligato
14、ry language such as “must“ and the negative equivalents are used to express requirements. The use of such words does not suggest that compliance with the Recommendation is required of any party. INTELLECTUAL PROPERTY RIGHTSITU draws attention to the possibility that the practice or implementation of
15、 this Recommendation may involve the use of a claimed Intellectual Property Right. ITU takes no position concerning the evidence, validity or applicability of claimed Intellectual Property Rights, whether asserted by ITU members or others outside of the Recommendation development process. As of the
16、date of approval of this Recommendation, ITU had not received notice of intellectual property, protected by patents, which may be required to implement this Recommendation. However, implementers are cautioned that this may not represent the latest information and are therefore strongly urged to cons
17、ult the TSB patent database at http:/www.itu.int/ITU-T/ipr/. ITU 2018 All rights reserved. No part of this publication may be reproduced, by any means whatsoever, without the prior written permission of ITU. Rec. ITU-T L.108 (03/2018) iii Table of Contents Page 1 Scope . 1 2 References . 1 3 Definit
18、ions 3 3.1 Terms defined elsewhere 3 3.2 Terms defined in this Recommendation . 3 4 Abbreviations and acronyms 4 5 Conventions 4 6 Environmental conditions . 4 6.1 Underground . 4 6.2 Aerial 4 6.3 Indoor . 4 7 Construction and characteristics of microduct system and cable elements 4 7.1 Fibre 4 7.2
19、Blown-in elements 5 7.3 Microducts 6 7.4 Protected microducts 6 7.5 Composite protected microduct/cable 7 8 Test methods . 7 8.1 Test methods for dimensions 7 8.2 Test methods for cable elements 7 8.3 Methods for testing mechanical characteristics 8 8.4 Test methods for environmental characteristics
20、 . 10 8.5 Test methods for fire safety 11 8.6 Test methods for installation performance . 11 Appendix I Chinese experience 12 I.1 Product types of microducts . 12 I.2 Microduct inner clearance verification . 13 I.3 Blowing performance test for microcables or fibre units in microduct 14 I.4 Layout lo
21、cation selection for microduct . 16 Appendix II Chinese experience on effects of freezing conditions on microduct air-blown cables . 17 II.1 Introduction 17 II.2 Freezing test 17 II.3 Conclusion 20 Bibliography. 21 iv Rec. ITU-T L.108 (03/2018) Introduction Air blowing installation methods are based
22、 on viscous drag acting upon a cable within a duct by forcing a continuous high-speed airflow through the duct. The velocity of the moving air propels the cable and makes it advance at a typical speed supported by the blowing equipment. When using blowing techniques, there is generally no pulling fo
23、rce at the front end of the cable; the airflow exerts a distributed force along the entire cable. In addition, connection to a pulling cord is not needed. Generally, the blowing force is an order of magnitude lower than the typical force involved in other installation methods, for example pulling te
24、chniques, thus reducing installation hazards. Additionally, with this technique, bends in a duct run are of less concern than with pulling techniques, so, generally, the installation speed increases and longer lengths of cable can be installed. Cables are installed with low stress levels, leaving th
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ITUTL1082018OPTICALFIBRECABLEELEMENTSFORMICRODUCTBLOWINGINSTALLATIONAPPLICATIONSTUDYGROUP15PDF

链接地址:http://www.mydoc123.com/p-799366.html