1、 TECHNICAL REPORT ISA-TR5.1.01/ISA-TR77.40.01-2012 Functional Diagram Usage Approved 10 August 2012ISA-TR5.1.01/ISA-TR77.40.01-2012 - 2 - Copyright 2012 ISA. All rights reserved. ISA-TR5.1.01/ISA-TR77.40.01-2012 Functional Diagram Usage ISBN: 978-1-937560-06-5 Copyright 2012 by ISA. All rights reser
2、ved. Not for resale. Printed in the United States of America. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means (electronic mechanical, photocopying, recording, or otherwise), without the prior written permission of the Publisher.
3、 ISA 67 Alexander Drive P.O. Box 12277 Research Triangle Park, North Carolina 27709 - 3 - ISA-TR5.1.01/ISA-TR77.40.01-2012 Copyright 2012 ISA. All rights reserved. Preface This preface, as well as all footnotes and annexes, is included for information purposes and is not part of ISA-TR5.1.01/ISA-TR7
4、7.40.01-2012. This document has been prepared as part of the service of ISA toward a goal of uniformity in the field of instrumentation. To be of real value, this document should not be static but should be subject to periodic review. Toward this end, the Society welcomes all comments and criticisms
5、 and asks that they be addressed to the Secretary, Standards and Practices Board; ISA; 67 Alexander Drive; P. O. Box 12277; Research Triangle Park, NC 27709; Telephone (919) 549-8411; Fax (919) 549-8288; E-mail: standardsisa.org. The ISA Standards and Practices Department is aware of the growing nee
6、d for attention to the metric system of units in general, and the International System of Units (SI) in particular, in the preparation of instrumentation standards. The Department is further aware of the benefits to USA users of ISA standards of incorporating suitable references to the SI (and the m
7、etric system) in their business and professional dealings with other countries. Toward this end, this Department will endeavor to introduce SI-acceptable metric units in all new and revised standards, recommended practices, and technical reports to the greatest extent possible . Standard for Use of
8、the International System of Units (SI): The Modern Metric System, published by the American Society for Testing provides outputs in response to external inputs and internal logic (NFPA 85: Boiler and Combustion Systems Hazards Code, 2011 Edition) 3.14 macro: a set of functions combined as a specific
9、 program to be run as a single task. The task is a subset of the controllers program but executes repeatedly for similar devices or applications with unique inputs and outputs. 3.15 measurement: the determination of the existence or the magnitude of a variable ISA-51.1-1979 (R1993) 3.16 multiple inp
10、ut multiple output: an algorithm/program, such as model predictive control, neural net, expert system, etc., that computes one or more output demands, biases, or setpoints based on multiple inputs 3.17 process: any operation or sequence of operations involving a change of energy, state, composition,
11、 dimension, or other properties that may be defined with respect to a datum ISA-51.1-1979 (R1993) 3.18 process measurement: the acquisition of information that establishes the magnitude of process qualities. ISA-51.1-1979 (R1993) 3.19 process variable: any variable property of a process; used in thi
12、s standard to apply to all variables other than instrument signals ISA-51.1-1979 (R1993) 3.20 program: a repeatable sequence of actions that defines the status of outputs as a fixed relationship to a set of inputs 3.21 setpoint: an input variable that sets the desired value of the controlled variabl
13、e; may be manually set, automatically set, or programmed. Its value is expressed in the same units as the controlled variable. 4 Abbreviations (Acronyms) HMI human machine interface I/O input/output MIMO multiple input multiple output MOV motor operated valve PID - proportional integral derivative -
14、 13 - ISA-TR5.1.01/ISA-TR77.40.01-2012 Copyright 2012 ISA. All rights reserved. 5 Preparation of functional diagrams This report is concerned with the functional diagrams normally prepared in the early stages of system conception from the mechanical or process flow sheet. Functional diagrams normall
15、y are revised and kept current over the complete system life cycle as system design progresses through the various stages of negotiations, quotation, contract award, reduction to final equipment, system checkout, installation, and ongoing system enhancements. They are also included as part of the sy
16、stem instructions. The functional diagrams define functions of a control configuration that are independent of the hardware and firmware of the control system used for process automation. Functional diagrams are a method to document application software and transfer information for implementation in
17、to the selected control system. A functional diagram may be more or less detailed, depending on its intended use. The amount of detail in a logic diagram depends on the degree of refinement of the logic and on whether auxiliary, essentially non-logic, information is included. Simplified diagrams can
18、 be drawn by omitting details that may be obvious. This report is intended to provide sufficient information to enable anyone with a reasonable amount of process and instrumentation knowledge, who is reviewing documents depicting process measurement and control, to understand the means of measuremen
19、t and control of the process. This report is suitable for use whenever reference to measurement and/or control instrumentation, control devices and/or functions, or software applications and/or functions is required for the purposes of symbolizing and identification. 5.1 Basic symbols A logic symbol
20、 comprises an outline or a combination of outlines together with one or more qualifying identifications and/or qualifying texts. Basic and complex logic symbols with minimum inputs need not specify input names. Logic symbols with multiple inputs can have input name identifiers to specify the signal
21、functions within the algorithm. New function or algorithm symbols should represent an encapsulated software component (i.e., function block) that exists within a systems library. 5.2 Advanced symbols With the introduction of microprocessor-based systems, suppliers have developed advanced algorithms
22、that are not represented by previous PMC 22.1, the German Institute for Standardization (DIN), the International Electrotechnical Commission (IEC), or ISA-5.1 standards. While following the intent of these standards, suppliers either create a new symbol or group existing symbols to represent the new
23、 algorithm. The problem occurs in understanding what function that symbol really represents and the symbols boundaries. Thus, advanced symbols depict new control algorithms via a combination of existing symbols, new control algorithms with multiple functions, and new control algorithm s previously u
24、navailable with electric analog systems. ISA-TR5.1.01/ISA-TR77.40.01-2012 - 14 - Copyright 2012 ISA. All rights reserved. 5.2.1 Combination of symbols A control algorithm containing multiple mathematical functions may be represented by combining multiple symbols within one block, as shown in Figure
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ISATR5101TR7740012012FUNCTIONALDIAGRAMUSAGEPDF

链接地址:http://www.mydoc123.com/p-789968.html