FORD FLTM EU-BJ 053-1-2000 HYDRAULIC FLUID PARTICLE CONTAMINATION COUNT.pdf
《FORD FLTM EU-BJ 053-1-2000 HYDRAULIC FLUID PARTICLE CONTAMINATION COUNT.pdf》由会员分享,可在线阅读,更多相关《FORD FLTM EU-BJ 053-1-2000 HYDRAULIC FLUID PARTICLE CONTAMINATION COUNT.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、 FORD LABORATORY TEST METHOD EU-BJ 053-01 Date Action Revisions 2000 08 31 Revised Editorial no technical change A. Cockman 1994 02 28 Printed copies are uncontrolled Page 1 of 5 Copyright 2000, Ford Global Technologies, Inc. HYDRAULIC FLUID PARTICLE CONTAMINATION COUNT Application This method is us
2、ed to determine the particle type and distribution of contaminants in hydraulic systems. Apparatus Required Projection Microscope Cross slide and lenses of the required magnific ations. Millipore Fluid Sampling Kit* Catalogue No. XX 6403730 Millipore Filter Syringe* Catalogue No. XX 62 000 01, with
3、2 - way valve, Catalogue No. XX 62 000 02. Solvent Filtering Dispenser* With filter. Catalogue No. XX 66 025 00. Forceps* Catalogue No. XX 62 000 06. Microscope Slides 1. 50 x 50 mm; 1.7 g 2. 50 x 70 mm; 12.65 g Bulldog Clips For microscope slides. Counting Graticule (see sketch) Hand Counter *Sourc
4、e: Millipore House Millipore Filter GmbH Abbey Road 6078 Neu - Isenburg Londo n NW10 7SP Siemensstrasse 20 FORD LABORATORY TEST METHOD EU-BJ 053-01 Page 2 of 5 Copyright 2000, Ford Global Technologies, Inc. Materials Required Petroleum Ether (A.R.) Immersion Oil* Catalogue No. XX 70 000 50 *Source:
5、Millipore House Millipore Filter GmbH Abbey Road 6078 Neu - Isenburg London NW10 7SP Siemensstrasse 20 Conditioning and Test Conditions All test values indicated herein are based on material conditioned in a controlled atmosphere of 23 +/ - 2 C and 50 +/ - 5 % relative humidity for not less than 24
6、h prior to testing and tested under the same conditions unless otherwise spe cified. Procedure Sampling Method Using Monitor After installation of the quick release valves to draw off the fluid, the following procedure shall be used: 1. The pressure on the hydraulic fluid to be filtered through the
7、monitor shall not exceed 800 kN/m 2 2. The sampler is screwed off and the cover caps removed from the monitor and kept for later refitting. Then, the monitor is fitted to the lower part of the sampler with the surface where the filter is applied. 3. Sampler is tightly rescrewed and connection is mad
8、e between bypass tube from the 3 - way valve to one of the openings located on the side of the sampler. 4. Direct coupling is made from sampler to a 200 mL measuring bottle graduated at 100 mL and 200 mL. 5. Remove caps from quick release valve and sampling tubing, with the 3 - way valve in the “shu
9、t off“ position. The quick release device is pressed and the sampling tube tightly inserted into the valve. Then release the quick release device. 6. Turn the 3 -way valve to “flush“ position; a llow 100 mL fluid to flush the bypass tube, the sampling cock, the tube and the 3 - way valve. 7. Fill th
10、e measuring bottle up to the 100 mL mark with hydraulic fluid, turn 3 - way valve to “test“ position. Allow 100 mL fluid to pass the filter and to flow into the measuring bottle. Then turn 3 -way valve to the “off“ position. FORD LABORATORY TEST METHOD EU-BJ 053-01 Page 3 of 5 Copyright 2000, Ford G
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDFLTMEUBJ05312000HYDRAULICFLUIDPARTICLECONTAMINATIONCOUNTPDF

链接地址:http://www.mydoc123.com/p-747814.html