FORD FLTM BN 113-1-2001 BOND STRENGTH OF TRIM ASSEMBLIES (Replaces FLTM BN 013-01).pdf
《FORD FLTM BN 113-1-2001 BOND STRENGTH OF TRIM ASSEMBLIES (Replaces FLTM BN 013-01).pdf》由会员分享,可在线阅读,更多相关《FORD FLTM BN 113-1-2001 BOND STRENGTH OF TRIM ASSEMBLIES (Replaces FLTM BN 013-01).pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、FORD LABORATORY TEST METHOD BN 113-01 2001 O924 2000 03 07 BOND STRENGTH OF TRIM ASSEMBLIES Revised Editorial - no technical change A. Cockman Revised Editorial - no technical change A. Cockman Application This procedure is used to evaluate the bond strength of trim assemblies manufactured by a heat
2、 bonding process. Apparatus Required Tensile Machine The tensile testing machine shall have a full scale range of O - 50 N with an accuracy of +/- 1 % in load indication. Humidity Cabinet Maintained at 98 +/- 2 % relative humidity and 38 +/- 2 OC. Cold Box -35 +/- 1 OC. Oven A mechanical convection
3、oven capable of maintaining 85 +/- 2 “C and 105 +/- 2 OC. Conforming to IS0 188/ASTM E 145 Type IIA normal oven, 150 +/- 50 air changes per hour. Conditioning and Test Conditions All test values indicated herein are based on material conditioned in a controlled atmosphere of 23 +/- 2 “C and 50 +/- 5
4、 % relative humidity for not less than 24 h prior to testing and tested under the same conditions unless otherwise specified. Procedure Samples of the materials used in the assembly are bonded under specified conditions. The bond strength of the materials is determined in a tensile test machine befo
5、re and after an accelerated aging cycle of heat, cold and humidity. A properly bonded assembly will exhibit no greater loss in bond strength after aging than that permitted by the Engineering specification. I Date I Action I Revisions I 1995 0929 I I CopyrightO2001, Ford Global Technologies, Inc FOR
6、D LABORATORY TEST METHOD BN 113-01 Bonding of Samples Prepare bonded test assemblies that meet the Engineering Material Specification. The assembly shall consist of the approved trim cover, molding, bonding, padding, adhesive, subfoundation and/or foundation board materials as used in production ass
7、emblies in which the material being evaluated will be employed. Dielectric Bonding Conditions (when used) For each test, bond the assembly, using a 2.4 mm wide aluminum or brass die bar, using a pressure range of 862 - 2068 kPa at 3000 R.F. volts (peak) minimum at 13.5 megacycles or 2400 R.F. volts
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDFLTMBN11312001BONDSTRENGTHOFTRIMASSEMBLIESREPLACESFLTMBN01301PDF

链接地址:http://www.mydoc123.com/p-747245.html