EN 60079-35-1-2011 en Explosive atmospheres - Part 35-1 Caplights for use in mines susceptible to firedamp - General requirements - Construction and testing in relation to the risk.pdf
《EN 60079-35-1-2011 en Explosive atmospheres - Part 35-1 Caplights for use in mines susceptible to firedamp - General requirements - Construction and testing in relation to the risk.pdf》由会员分享,可在线阅读,更多相关《EN 60079-35-1-2011 en Explosive atmospheres - Part 35-1 Caplights for use in mines susceptible to firedamp - General requirements - Construction and testing in relation to the risk.pdf(26页珍藏版)》请在麦多课文档分享上搜索。
1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationExplosive atmospheresPart 35-1: Caplights for use in mines susceptible to firedamp General requirements Construction and testing in relation to the risk of explosionBS EN 60079-3
2、5-1:2011Incorporating corrigendum September 2011National forewordThis British Standard is the UK implementation of EN 60079-35-1:2011,withdrawn.The UK participation in its preparation was entrusted to Technical CommitteeEXL/31, Equipment for explosive atmospheres.A list of organizations represented
3、on this committee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. ISBN 978 0 580 76787 6 ICS 29.260.20 Compliance with a British Standard cannot confer immunity fro
4、m legal obligations.This British Standard was published under the authority of the Standards Policy and Strategy Committee on 30 September 2011.Amendments/corrigenda issued since publicationDate Text affectedBRITISH STANDARDBS EN 60079-35-1:2011 The British Standards Institution 2012Published by BSI
5、 Standards Limited 201231 March 2012 Implementation of CENELEC corrigendum September 2011: Corrected examples in Annex ZY, Marking sectionIEC 60079-35-1:2011. It supersedes BS EN 62013-1:2006, which isincorporating corrigendum September 2011. It is identical toEUROPEAN STANDARD EN 60079-35-1 NORME E
6、UROPENNE EUROPISCHE NORM August 2011 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Management Centre: Avenue Marnix 17, B - 1000 Brussels 2011 CENELEC - All rights of exploitation in an
7、y form and by any means reserved worldwide for CENELEC members. Ref. No. EN 60079-35-1:2011 E ICS 29.260.20Supersedes EN 62013-1:2006 English version Explosive atmospheres - Part 35-1: Caplights for use in mines susceptible to firedamp - General requirements - Construction and testing in relation to
8、 the risk of explosion (IEC 60079-35-1:2011) Atmosphres explosives - Partie 35-1: Lampes-chapeaux utilisables dans les mines grisouteuses - Exigences gnrales - Construction et essais lis au risque dexplosion (CEI 60079-35-1:2011) Kopfleuchten fr die Verwendung in schlagwettergefhrdeten Grubenbauen -
9、 Teil 35-1: Allgemeine Anforderungen - Konstruktion und Prfung in Relation zum Explosionsrisiko (IEC 60079-35-1:2011) This European Standard was approved by CENELEC on 2011-06-30. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving
10、this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official vers
11、ions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of
12、 Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the Uni
13、ted Kingdom. Incorporating corrigendum September 2011Foreword The text of document 31/921/FDIS, future edition 1 of IEC 60079-35-1, prepared by IEC TC 31, Equipment for explosive atmospheres, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 60079-35-1 on 2011-06-30. T
14、his European Standard supersedes EN 62013-1:2006. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and CENELEC shall not be held responsible for identifying any or all such patent rights. The following dates were fixed: latest
15、date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2012-03-30 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2014-06-30 This European Standard has been prepared under a
16、mandate given to CENELEC by the European Commission and the European Free Trade Association and covers essential requirements of EC Directive ATEX (94/9/EC). See Annex ZZ. Annexes ZA, ZY and ZZ have been added by CENELEC. _ Endorsement notice The text of the International Standard IEC 60079-35-1:201
17、1 was approved by CENELEC as a European Standard without any modification. _ BS EN 60079-35-1:2011 EN 60079-35-1:2011 (E) 2 Annex ZA (normative) Normative references to international publications with their corresponding European publications The following referenced documents are indispensable for
18、the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. NOTE When an international publication has been modified by common modifications, indicated by (mod), the
19、relevant EN/HD applies. Publication Year Title EN/HD Year IEC 60050-426 - International Electrotechnical Vocabulary - Part 426: Equipment for explosive atmospheres - - IEC 60050-845 - International Electrotechnical Vocabulary (IEV) - Chapter 845: Lighting - - IEC 60079-0 - Explosive atmospheres - Pa
20、rt 0: Equipment - General requirements EN 60079-0 - IEC 60079-1 - Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures “d“ EN 60079-1 - IEC 60079-7 - Explosive atmospheres - Part 7: Equipment protection by increased safety “e“ EN 60079-7 - IEC 60079-11 - Explosive atmosphere
21、s - Part 11: Equipment protection by intrinsic safety “i“ EN 60079-11 - IEC 60127-2 - Miniature fuses - Part 2: Cartridge fuse-links EN 60127-2 - IEC 60332-1-1 - Tests on electric and optical fibre cables under fire conditions - Part 1-1: Test for vertical flame propagation for a single insulated wi
22、re or cable - ApparatusEN 60332-1-1 - IEC 60332-1-2 - Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulated wire or cable - Procedure for 1 kW pre-mixed flame EN 60332-1-2 - IEC 60664-3 - Insulation coordination for eq
23、uipment within low-voltage systems - Part 3: Use of coating, potting or moulding for protection against pollution EN 60664-3 - UL 1642 - Standard for Lithium Batteries - - BS EN 60079-35-1:2011 EN 60079-35-1:2011 (E) 3 Annex ZY (informative) Significant changes between EN 60079-35-1:2011 and EN 6201
24、3-1: 2006 This European Standard supersedes EN 62013-1:2006. The significant changes with respect to EN 62013-1:2006 are as listed below. Type Significant Changes Clause Minor and editorial changes Extension Major technical changes This first edition cancels and replaces EN 62013-1: 2006, and consti
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN600793512011ENEXPLOSIVEATMOSPHERESPART351CAPLIGHTSFORUSEINMINESSUSCEPTIBLETOFIREDAMPGENERALREQUIREMENTSCONSTRUCTIONANDTESTINGINRELATIONTOTHERISKPDF

链接地址:http://www.mydoc123.com/p-717583.html