EN 50131-8-2009 en Alarm systems - Intrusion and hold-up systems - Part 8 Security fog device systems《报警系统 侵入和拦劫系统 第8部分 安全烟雾设备 系统》.pdf
《EN 50131-8-2009 en Alarm systems - Intrusion and hold-up systems - Part 8 Security fog device systems《报警系统 侵入和拦劫系统 第8部分 安全烟雾设备 系统》.pdf》由会员分享,可在线阅读,更多相关《EN 50131-8-2009 en Alarm systems - Intrusion and hold-up systems - Part 8 Security fog device systems《报警系统 侵入和拦劫系统 第8部分 安全烟雾设备 系统》.pdf(28页珍藏版)》请在麦多课文档分享上搜索。
1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI British StandardsWB9423_BSI_StandardColCov_noK_AW:BSI FRONT COVERS 5/9/08 12:55 Page 1Alarm systems Intrusionand hold-up systems Part 8: Security fog device/systemsBS EN 50131-8:2009National foreword
2、This British Standard is the UK implementation of EN 50131-8:2009. It supersedes BS 7939:1999 which is withdrawn.The UK participation in its preparation was entrusted to Technical CommitteeGW/1, Electronic security systems.A list of organizations represented on this committee can be obtained onreque
3、st to its secretary.This publication does not purport to include all the necessary provisions of acontract. Users are responsible for its correct application. BSI 2009ISBN 978 0 580 54903 8ICS 13.320Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard
4、 was published under the authority of the StandardsPolicy and Strategy Committee on 31 July 2009Amendments issued since publicationAmd. No. Date Text affectedBRITISH STANDARDBS EN 50131-8:2009EUROPEAN STANDARD EN 50131-8 NORME EUROPENNE EUROPISCHE NORM May 2009 CENELEC European Committee for Electro
5、technical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: avenue Marnix 17, B - 1000 Brussels 2009 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No.
6、EN 50131-8:2009 E ICS 13.320 English version Alarm systems - Intrusion and hold-up systems - Part 8: Security fog device/systems Systmes dalarme - Systmes dalarme contre lintrusion et les hold-up - Partie 8: Systmes/dispositifs gnrateurs de fume Alarmanlagen - Einbruch- und berfallmeldeanlagen - Tei
7、l 8: Nebelgerte/Nebelsysteme fr Sicherungsanwendungen This European Standard was approved by CENELEC on 2009-04-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without
8、 any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language
9、made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the Czech Republic, Denmark
10、, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. BS EN 50131-8:2009EN 50131-8:2009 2 Foreword This European S
11、tandard was prepared by the Technical Committee CENELEC TC 79, Alarm systems. The text of the draft was submitted to the formal vote and was approved by CENELEC as EN 50131-8 on 2009-04-01. The following dates were fixed: latest date by which the EN has to be implemented at national level by publica
12、tion of an identical national standard or by endorsement (dop) 2010-04-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2012-04-01 The series EN/TS 50131 will consist of the following parts, under the general title “Alarm systems Intrusion and hold-up
13、 systems”: Part 1 System requirements Part 2-2 Intrusion detectors Passive infrared detectors Part 2-3 Requirements for microwave detectors Part 2-4 Requirements for combined passive infrared and microwave detectors Part 2-5 Requirements for combined passive infrared and ultrasonic detectors Part 2-
14、6 Opening contacts (magnetic) Part 2-7-1 Intrusion detectors Glass break detectors (acoustic) Part 2-7-2 Intrusion detectors Glass break detectors (passive) Part 2-7-3 Intrusion detectors Glass break detectors (active) Part 3 Control and indicating equipment Part 4 Warning devices Part 5-3 Requireme
15、nts for interconnections equipment using radio frequency techniques Part 6 Power supplies Part 7 Application guidelines Part 8 Security fog devices/systems _ BS EN 50131-8:2009 3 EN 50131-8:2009 Contents Introduction . 5 1 Scope . 6 2 Normative references. 6 3 Definitions and abbreviations . 6 3.1 D
16、efinitions 6 3.2 Abbreviations . 7 4 Environmental 7 4.1 Environmental classification . 7 4.2 Environmental tests . 7 5 Access levels 8 6 Regulation requirements . 8 6.1 General 8 6.2 Electrical safety 8 6.3 Safety data sheets . 8 6.4 EMC requirements . 8 6.5 Warning signs 8 6.6 Pressure vessels 8 7
17、 Device/system parameters 9 7.1 Performance . 9 7.2 Battery backup requirement . 9 7.3 IP/IK rating . 9 7.4 Wire free interconnections . 9 8 General requirements 9 8.1 Tamper . 9 8.2 Fog neutralisation. 9 8.3 Discharge nozzle10 8.4 Fog eject limiter 10 8.5 Heating unit 10 8.6 Overheating 10 8.7 Acci
18、dental triggering 10 8.8 Isolation of the security fog system 10 8.9 Fixings 10 9 Operational requirements .10 9.1 Communication 10 9.2 Fault monitoring .11 9.3 Power failure 11 9.4 Efficacy .11 9.5 Non-toxicity 12 9.6 Residue 12 BS EN 50131-8:2009EN 50131-8:2009 4 10 Consumables 12 10.1 Replenishme
19、nt .12 10.2 Formulation 12 10.3 Traceability .12 11 Marking 12 12 Documentation .12 13 Design, installation, operation and maintenance (informative) 12 Annex A (normative) Performance tests 13 Annex B (normative) Security fog system warning sign 20 Annex C (informative) Guidance on design, installat
20、ion, operation and maintenance of the security fog system 22 Bibliography 24 Figures Figure A.1 Test chamber 17 Figure A.2 Target 18 Figure A.3 Partial target 19 Figure B.1 Security fog system warning sign . 20 Tables Table A.1 . 15 Table A.2 . 16 Table B.1 How to calculate the size of sign you need
21、 21 BS EN 50131-8:2009 5 EN 50131-8:2009 Introduction This European Standard applies to a security fog system that is part of an Intruder and Hold-up Alarm System (I b) Clause 10: cold test operational; c) Clause 14: damp heat, cyclic operational; d) Clause 17: sulphur dioxide (SO2) (endurance); e)
22、Clause 20: impact operational; f) Clause 22: vibration sinusoidal (operational); g) Clause 23: vibration sinusoidal (endurance); h) Clause 27: electromagnetic compatibility, immunity (operational). 5 Access levels The access levels used in this standard shall be as stated in EN 50131-1:2006, 8.3.1,
23、except for access level 2. Access level 2 “user” shall not be able to access the security fog system. 6 Regulation requirements 6.1 General The security fog system shall operate to the following minimum relevant European regulations. 6.2 Electrical safety The electrical (safety) construction of the
24、security fog system shall be to EN 60065. 6.3 Safety data sheets The transport, storage and handling of consumables, shall comply with the requirements stated on the safety data sheets. 6.4 EMC requirements The security fog system shall meet the EMC conditions and the severity levels defined in EN 6
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN5013182009ENALARMSYSTEMSINTRUSIONANDHOLDUPSYSTEMSPART8SECURITYFOGDEVICESYSTEMS 报警 系统 侵入 拦劫 部分 安全 烟雾

链接地址:http://www.mydoc123.com/p-716727.html