EN 50131-6-2008 en Alarm systems - Intrusion and hold-up systems - Part 6 Power supplies (Incorporates Amendment A1 2014)《报警系统 侵入和拦劫系统 第6部分 电源》.pdf
《EN 50131-6-2008 en Alarm systems - Intrusion and hold-up systems - Part 6 Power supplies (Incorporates Amendment A1 2014)《报警系统 侵入和拦劫系统 第6部分 电源》.pdf》由会员分享,可在线阅读,更多相关《EN 50131-6-2008 en Alarm systems - Intrusion and hold-up systems - Part 6 Power supplies (Incorporates Amendment A1 2014)《报警系统 侵入和拦劫系统 第6部分 电源》.pdf(46页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARDBS EN 50131-6:2008Alarm systems Intrusion and hold-up systems Part 6: Power suppliesICS 13.310g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g
2、3g47g36g58BS EN +A1:2014BS EN 50131-6:2008+A1:2014ISBN 978 0 580 75604 7Amendments/corrigenda issued since publicationDate Comments30 September 2014 Implementation of CENELEC amendment A1:2014This British Standard was published under the authority of the Standards Policy and Strategy Committee on 29
3、 February 2008 The British Standards Institution 2014. Published by BSI Standards Limited 2014National forewordThis British Standard is the UK implementation of EN 50131-6:2008+A1:2014. It supersedes BS EN 50131-6:2008 which is withdrawn.The start and finish of text introduced or altered by amendmen
4、t is indicated in the text by tags. Tags indicating changes to CENELEC text carry the number of the CENELEC amendment. For example, text altered by CENELEC amendment A1 is indicated by .The UK participation in its preparation was entrusted by Technical Committee GW/1, Electronic security systems to
5、Subcommittee GW/1/1, Alarm components.A list of organizations represented on this subcommittee can be obtained on request to its secretary.The publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.Compliance with a Briti
6、sh Standard cannot confer immunity from legal obligations.EUROPEAN STANDARD EN 50131-6 NORME EUROPENNE EUROPISCHE NORM January 2008 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central
7、 Secretariat: rue de Stassart 35, B - 1050 Brussels 2008 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 50131-6:2008 E ICS 13.310 Supersedes EN 50131-6:1997English version Alarm systems - Intrusion and hold-up systems - Part 6: P
8、ower supplies Systmes dalarme - Systmes dalarme contre lintrusion et les hold-up - Partie 6: Alimentation Alarmanlagen - Einbruch- und berfallmeldeanlagen - Teil 6: Energieversorgungen This European Standard was approved by CENELEC on 2007-12-01. CENELEC members are bound to comply with the CEN/CENE
9、LEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any C
10、ENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versio
11、ns. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania,
12、Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. EN 50131-6:2008+A1June 2014EN 50131-6:2008 - 2 - Foreword This European Standard was prepared by the Technical Committee CENELEC TC 79, Alarm systems. The text of the daft was submitted to the Unique Acceptance Procedure and was
13、approved by CENELEC as EN 50131-6 on 2007-12-01. This European Standard supersedes EN 50131-6:1997 + corrigendum April 1998. The following dates were fixed: latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 20
14、08-12-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2010-12-01 EN 50131 will consist of the following parts, under the general title Alarm systems - Intrusion and hold-up systems: Part 1 System requirements Part 22 Intrusion detectors Passive infra
15、red detectors Part 23 Intrusion detectors Microwave detectors Part 24 Intrusion detectors Combined passive infrared / Microwave detectors Part 25 Intrusion detectors Combined passive infrared / Ultrasonic detectors Part 26 Intrusion detectors Opening contacts (magnetic) Part 271 Intrusion detectors
16、Glass break detectors Acoustic Part 272 Intrusion detectors Glass break detectors Passive Part 273 Intrusion detectors Glass break detectors Active Part 3 Control and indicating equipment Part 4 Warning devices Part 53 Requirements for interconnections equipment using radio frequency techniques Part
17、 6 Power supplies Part 7 Application guidelines Part 8 Security fog devices EN 50131-6:2008 - 2 - Foreword This European Standard was prepared by the Technical Committee CENELEC TC 79, Alarm systems. The text of the daft was submitted to the Unique Acceptance Procedure and was approved by CENELEC as
18、 EN 50131-6 on 2007-12-01. This European Standard supersedes EN 50131-6:1997 + corrigendum April 1998. The following dates were fixed: latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2008-12-01 latest date b
19、y which the national standards conflicting with the EN have to be withdrawn (dow) 2010-12-01 EN 50131 will consist of the following parts, under the general title Alarm systems - Intrusion and hold-up systems: Part 1 System requirements Part 22 Intrusion detectors Passive infrared detectors Part 23
20、Intrusion detectors Microwave detectors Part 24 Intrusion detectors Combined passive infrared / Microwave detectors Part 25 Intrusion detectors Combined passive infrared / Ultrasonic detectors Part 26 Intrusion detectors Opening contacts (magnetic) Part 271 Intrusion detectors Glass break detectors
21、Acoustic Part 272 Intrusion detectors Glass break detectors Passive Part 273 Intrusion detectors Glass break detectors Active Part 3 Control and indicating equipment Part 4 Warning devices Part 53 Requirements for interconnections equipment using radio frequency techniques Part 6 Power supplies Part
22、 7 Application guidelines Part 8 Security fog devices BS EN 50131-6:2008+A1:2014EN 50131-6:2008+A1:2014 - 2 -EN 50131-6:2008/A1:2014 2 Foreword This document (EN 50131-6:2008/A1:2014) has been prepared by CLC/TC 79 “Alarm systems“. The following dates are fixed: latest date by which this document ha
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN5013162008ENALARMSYSTEMSINTRUSIONANDHOLDUPSYSTEMSPART6POWERSUPPLIESINCORPORATESAMENDMENTA12014 报警 系统

链接地址:http://www.mydoc123.com/p-716726.html