ECA TEP 109-1981 Test Criteria for X-Ray Image Intensifier Tubes《X射线图像增强管测试标准》.pdf
《ECA TEP 109-1981 Test Criteria for X-Ray Image Intensifier Tubes《X射线图像增强管测试标准》.pdf》由会员分享,可在线阅读,更多相关《ECA TEP 109-1981 Test Criteria for X-Ray Image Intensifier Tubes《X射线图像增强管测试标准》.pdf(18页珍藏版)》请在麦多课文档分享上搜索。
1、EIA TEPIOS BI m 3234b00 O007440 8 m OCTOBER 1981 7 TEST CRITERIA . FOR X-RAY IMAGE INTENSIFIER TUBES FORMULATED BY EIA TUBE ENGINEERING PANEL ADVISORY COUNCIL (TEPAC) TEPAC PUBLICATION No. 109 (Revision of TEPAC Suggested Standard No. 9) EIA TEP307 83 W 3234600 0007443 T NOTICE EIA Engineering Stand
2、ards and Publications are designed to serve the public interest through eliminating misunderstandings between manufacturers and purchasers, facilitatirig interchangeability and improvement of products, and assisting the purchaser in selecting and obtaining with minimum delay the proper product for h
3、is particular need. Existence of such Standards and Publications shall not in any respect preclude any member or non-member of EIA from manufacturing or selling products not conforming to such Standards and Publications, nor shall the existence of auch Standards and Publications preclude their volun
4、tary use by those other than EIA members, whether the standard is to be used either domestically or internationally. Recommended Standards and Publications are adopted by EIA without regard to whether or not their adoption may involve patents on articles, materials, or processes. By such action, EIA
5、 does not assume any liability to any patent owner, nor does it assume any obligation whatever to parties adopting the Recom- mended Standard or Publication. This document has been developed to recommend a standardized method of measurement of x-radiation from CRTS for tube manufacturer compliance w
6、ith HHS Bureau of Radiological Health Regulations on this subject, Published by ELECTRONIC INDUSTRIES ASSOCIATION Engineering Department 2001 Eye Street, N.W. Washington, D.C. 20006 .- PRICE: $5.50 Printed in U.S.A. c- -. EIA TEPLOS BL m 3234b00 00074i.12 L m TEPAC Publication No. 109 Paragraph 1.0
7、2, o 3.0 4.0 FIGURE 1: FIGURE 2: FIGURE 3: FIGURE 4: FIGURE 5: FIGURE 6: FIGURE 7: FIGURE 8: FIGURE 9: FIGURE 10: FIGURE 11: APPENDIX I: APPENDIX II: TEST CRITERIA FOR X-RAY IMAGE INTENSIFIER TUBES TABLE OF CONTENTS Purpose and Scope Definitions . Measurements Conversion Factor Useful Area and Field
8、 Diameter Useful Area (Calculated) X-Ray Test Resolution Chart Radiation Meacuremen t Se t-Up Resolving Power Measurement Set-up Resolving Power Test Plot Contrast Test Phantom Radiation Measurement Set-up Contrast Measurement Set-up Radiation Measurement Set-up Output Screen Brightness Page 2 2 3 5
9、 7 7 0 9 9 10 11 12 12 13 13 14 15 -1- - / EIA TEPLOS 81 m 3234600 0007443 3 m I- TEST CRITERIA FOR X-RAY IMAGE INTENSIFIER TUBES EIA/TEPAC PUBLICATION NO. 109 PREFACE The material herein was developed by the JT-4 Committee on Photosensitive Electron Tubes and previously issued in the form of a JEDE
10、C suggested Standard entitled “Test Standard for X-Ray Image Intensifier Tubes“ (JEDEC Suggested Standard No. 9, dated March 1969). a The document was transferred to the JT-20 Committee on Electro-Optic Devices who reaffirmed the publication for distribution under the cognizance of the EIA Tube Engi
11、neering Panel Advisory Council (TEPAC) as TEPAC Pub1 ication No. 109. EIA TEPLOS 81 = 3234b00 O007444 5 1.0 1.1 2.0 O 2.1 2.2 2.3 2.4 2.5 TEST CRITERIA FOR X-RAY IMAGE INTENSIFIER TUBES Purpose and Scope .- This document provides recommended test methods for the measurement and ratings of X-ray imag
12、e intensifier tubes. CAUTION: SAFETY CONSIDERATIONS Measuring instruments should be properZy grounded. Cau-bion should be -taken to avoid shock hazard, particularly in the vicinity of the anode connection and the voltage metering systems, . ment procedue. Safety glasses -should be worn at al2 times
13、during the measure- X-ray film badga skould be worn in accordance with estabZishsd plant safety practices for mon%torZng radiation dosage. Defini ti ons . X-ray Image Intensifier Tube - A vacuum tube containing an input screen which converts an X-ray pattern into an electron pattern and in which the
14、 electrons are accelerated and focused on to an output screen which converts the electron pattern into a light image of brightness greater than that of a fluoroscope screen, Useful Area - The area of the input plane enclosed by a circle having a radius over which the resolution is specified (see Fig
15、.1). Useful Field Diameter - The diameter of the X-ray beam, measured at the location of the object, which produces an X-ray shadow covering the useful area (see Fig. 1). Image Quality - The faithfulness of the reproduction of an X-ray pattern (see definitions 2.8 and 2.9). Input Screen - The surfac
16、e, either flat or curved, in which X-radiation is absorbed and in which the X-ray image is converted into either an image of fluorescent light or of electric charge. EIA TEPLOS BL m 3234600 0007445 7 m 2.6 2.7 2.8 2.9 2.10 3. O 3.1 3.1.1 3.1.2 3.1.3 Output Screen - The surface in which is located th
17、e phosphor which 9 displays a light image. Conversion Factor - The quotient of the brightness in foot lamberts (or candelas/m2) at the output screen by the input radiation in mR/minute. The P number phosphor of the output screen and the quality of the input radiation must be specified. 1 candela/m2
18、= 0.2919 foot lambert. 1 foot lambert = 3.426 candela/m2. Maximum Resolving Power - The number of space and bar combinations per cm (inch) of high x-ray contrast at the entrance plane such that the bars still can be discerned visually as separate entities at the output screen. Minimum Visible Contra
19、st - The difference in thickness of the X-ray absorption fil ter expressed as a percentage of the maximum thick- ness that produces a perceptible difference in brightness on the output screen at a specified exposure rate (see Fig. 7). The Entrance Plane - The plane in front of the input screen, thro
20、ugh which, according to the specifications of -the manufacturer, no part of the image intensifier will protrude (see Fig. 1). I ! , o Measurements - For the evaluation of an X-ray Image Intensifier, the fol lowing measurements chal 1 be made: 1) Useful Area 2) Image Quality 3) Conversion Factor The
21、Useful Area Place an X-ray tube at a distance of 71 cm entrance plane. 28 inches) from the Confine the X-ray beam in order to irradiate exactly the useful area Measure the diameter of the X-ray beam at the entrance plane = a cm (inches). O 3.1.4 3.1.5 3.1.6 3.1 7 3.2 3.2.1 O 3.2.2 EIA TEPLOS 81 3234
22、600 0007446 9 Reduce the X-ray-tube-entrance plane distance to 35.6 cm (14 inches). Confine the X-ray beam in order to irradiate exactly the useful area. Measure the diameter of the X-ray beam at the entrance plane = b cm (inches). The diameter of the useful area can now be calculated by the for- mu
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ECATEP1091981TESTCRITERIAFORXRAYIMAGEINTENSIFIERTUBESX 射线 图像 增强 测试 标准 PDF

链接地址:http://www.mydoc123.com/p-704560.html