ECA CB-12-1990 Gold Plating Study Test Report《镀金研究测试报告》.pdf
《ECA CB-12-1990 Gold Plating Study Test Report《镀金研究测试报告》.pdf》由会员分享,可在线阅读,更多相关《ECA CB-12-1990 Gold Plating Study Test Report《镀金研究测试报告》.pdf(26页珍藏版)》请在麦多课文档分享上搜索。
1、(u I o 7- m EIA CB-12 90 9 3234600 0000070 T 9 - * c EIA ENGINEERING .U-EXN - Gold Plating Study Test Report CB-12 SEPTEMBER 1990 ELECTRONIC INDUSTRIES ASSOCIATION ENGINEERING DEPARTMENT EIA CB-12 90 = 3234600 0000071i 1 NOTICE ELA Engineering Standards and Publications are designed to serve the pub
2、lic interest through eliminating misunderstandings between manufacturers and purchasers, facilitating interchangeability and improvement of products, and assisting the purchaser in selecting and obtaining with minimum delay the proper product for his particular need. Existence of such Standards and
3、Publications shall not in any respect preclude any member or nonmember of ELA from manufacturing or selling products not conforming to such Standards and Publications, nor shall the existence of such Standards and Publications preclude their voluntary use by those other than ELA members, whether the
4、 standard is to be used either domestically or internationally. Recommended Standards and Publications are adopted by EL4 without regard to whether their adoption may involve patents on articles, materials, or processes. By such action, EIA does not assume any liability to any patent owner, nor does
5、 it assume any obligation whatever to parties adopting the Recommended Standard or Publication. Technical Publications are. distinguished from EU Recommended Standards or Interim Standards, in that they contain a compilation of engineering data or information useful to the technical community, and r
6、epresent approaches to good engineering practices that are suggested by the formulating committee. This Publication is not intended to preclude or discourage other approaches that similarly represent good engineering practice, or that may be acceptable to, or have been accepted by, appropriate bodie
7、s. Parties who wish to bring other approaches to the attention of the formulating committee to be considered for inclusion in future revisions of this Publication are encouraged to do so. It is the intention of the formulating committee to revise and update this Publication from time to time as may
8、be occasioned by changes in technology, industry practice, or government regulations, or for other appropriate reasons. (CB-12 was formulated under the cognizance of the EIA P-5.1 Task Group on Gold Plating.) Published by ELECTRONIC INDUSTRIES ASSOCIATION Engineering Department 2001 Pennsylvania Ave
9、., N.W. Washington, D.C. 20006 PRICE: $16.00 Copyright 1990 All Rights Reserved Printed in U.S.A. ,- CI - EIA CB-12 90 m 3234600 O000072 3 m CB-12 TABE OF CONTENTS ITEM Introduction Test Satriples and Preparation Sample Size Applicable Documents Test Selection Contact Coding Contact Allocation Table
10、 1 Evaluation Program Chart Porosity Gold Finish Thickness Contact Engagement and Separation Forces Low Level Circuit Resistance Durability Vi brat ion Thermal Cycling with Humidity Temperature Life (Elevated Teniperature) Salt Spray kamination (Gold Finish) Special Notes Sunnnarized Test Results Co
11、ntad Engaging and Separation Forces Electrical Resistance Monitoring Plating Thickness Porosity i - PAGE NUMBER 2 3 4 4 4 5 5 6 7 8 9 9 9 10 11 12 13 14 14 15 16 17 19 24 24 . - EIA CB-12 90 3234600 0000073 5 = CB-12 Page 1 INTRODUCTION SCOPE : The purpose of this study is to evaluate the performanc
12、e characteristics of gold plating thicknesses when exposed to a severe series of environmental sequences. phenomenon which could potentially cause contact interface degradation. The program is designed to stress the component system beyond nom1 military qualification test sequences. established. The
13、 sequences as established were chosen for their impact on No pass/fail criteria was The data as generated is used for comparative purposes only. PARTICIPATING COMPANIES AND BASIC REPORTING FORMAT Three companies participated in performing the test program as established. For reporting purposes, all
14、data is anonymous and grouped. companies chose the product to be tested per the slash sheets of MIL-C-39029. Testing was performed by qualified laboratories. All said laboratories had current suitability status in effect as issued by DESC for the products involved. Participating Upon completion of t
15、esting, all data was suhitted to an independent agency. Said agency sumM1-ized and presented the data in the formt contained herein as approved by the EIA P-5.1 Task Group on gold plating. Upon completion of the report, all data was returned to the submitting companies for their own disposition. Cop
16、ies of the report were suhitte to each participating company only. The data presented herein is “grouped“. That is, the averages are the grand average of all data suhnitted from all participating companies. maximum data point was,the maximum observed from all data suhitted from all participating com
17、panies. The The comnittee wishes to acknowledge all participating companies for their time and resources in generating the data contained herein. participating in the test program were: Companies a) Dupont b.) Elco c) Texas Instrmts The independent agency collating the data was Contech Research, Inc
18、. I EIA CB-12 90 = 3234600 0000074 7 CB-12 Page 2 TEST SAMPLES AND PREPARATION 1. 2. 3. 4. 5. 6. Unless otherwise indicated all materials were certified by the manufadurer to be in accordance with the applicable product specification. The connectors as tested and suhitted were certified by the manuf
19、adurer as being fabricated and assembled utilizing nom1 production techniques comn for this type of product and inspected in accordance with the quality criteria as established for the product involved. All connectors were coded and identified to maintain continuity throughout the test sequences. Te
20、st lead attachment for electrical resistance monitoring was in accordance with the applicable product specification. Unless otherwise specified in the test procedures used, no further preparation was performed. Three different connector styles were evaluated in this study. connectors are categorized
21、 as follows: These a) b) c) Style A - Pin (dia. 1 and socket type Style B - Square post and contact type Style C - Blade and dual tine stamped contact , I ;-. EIA CB-12 90 3234600 0000075 9 CB-12 Page 3 SAMFLE SIZE Unless otherwise specified, the number of connectors suhnitted to the exposures and t
22、he number of data points monitored were in accordance with the indicated test plan. APPLICABLE DOCUMENTS 1. The following test standards were used in the performance of this evaluation. a) MIL-STD-1344 b) EIA Rs 364 2. The following products were sunitted to the exposure in accordance with the follo
23、wing specifications: a) MIL-C-55302 1. All test were performed in accordance with the sequences and procedures as specified herein. 2. See Test Plan Flow Diagram, Figure #1, for test sequences used. 1 e EIA CB-12 90 m 3234600 O000076 O m CB-12 Page 4 CONTACT CODING The contacts shall be coded as sho
24、wn below as a convenience for comparative evaluation. engagement and separation forces, crimp.contact resistance, low level circuit resistance and the final measurements, be carefully recorded so that a comparison can be made between the initial and final measurements on It is important that the ini
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ECACB121990GOLDPLATINGSTUDYTESTREPORT 镀金 研究 测试报告 PDF

链接地址:http://www.mydoc123.com/p-704137.html