1、A-A-54837 9999974 OL43627 98T = 1 INCH-POUND I A-A-54 8 3 7 12 April 1993 COMMERCIAL ITEM DESCRIPTION SYRINGE, IRRIGATING, Glass The General Services Administration has authorized the use of this Commercial Item Description as a replacement for Federal Specification GG-S-931, which is cancelled. Thi
2、s Commercial Item Description covers a bulb type glass irrigating syringes. Salient characteristics: Classification. The syringe shall be of the following types: TYPE I - Tapered Tip TYPE II - Cone Tip (rubber) TYPE III - Tapered Tip with removable tip Material. The syringe shall be fabricated from
3、borosilicate glass. The bulb and removable tip shall be fabricated from inert medical grade rubber or inert medical grade neoprene. Style and desisn. All the syringes shall be a bulb-type with a glass barrel. The Type I syringe shall have tapered glass tip. The Type II syringe shall have a rubber co
4、ne tip. with a removable rubber tip. The bulb shall form a leakproof seal with the syringe barrel. The bulb shall be capable of repeated sterilizations without any determental effects. The bulb shall be easily compressed and shall return to its original configuration without any permanent distortion
5、. The style and design of the syringe shall be in accordance with Figure 1. Each syringe shall be packaged in an individual container that shall protect the syringe during shipment and storage. The Type III syringe shall have a tapered glass tip AMSC N/A DISTRIBUTION STATEMENT A. distribution is unl
6、imited. Approved for public release; FSC 6515 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-54837 M 74 OL43b28 8lb M A-A-54 8 3 7 Markinq. The capacity and the manufacturers name or registered trademark shall be permanently marked on the syring
7、e. Workmanship. The syringe shall be free from defects which detract from its appearance or impair its serviceability. Unit. Each (EA). One syringe of the type and ounce specified, constitutes one unit. Quality Assurance Provisions. Responsibility for inspection. Unless otherwise specified in the co
8、ntract or purchase order, the contractor is responsible for the performance of all inspection requirements as specified herein. Except as otherwise specified in the contract or purchase order, the contractor may use his own or any facilities suitable for the performance of the inspection requirement
9、s specified herein, unless disapproved by the Government. The Government reserves the right to perform any of the inspections set forth in the specification where such inspections are deemed necessary to assure supplies and services conform to prescribed requirements. Records. Records of examination
10、s and tests performed by or for the contractor shall be maintained by the contractor and made available to the Government upon the Governments request, at any time, or from time to time, during the performance of the contract and for a period of three years after the delivery of the supplies to whic
11、h such records relate. Inspection. Inspection, as used herein, is defined as both examination (such as visual or auditory investigation without the use of special laboratory appliances or procedures) and testing (determination by technical means of physical and chemical properties) of the item. Exam
12、ination. Examination shall be conducted to determine compliance with specification requirements. Samplinq for examination. Sampling for examination shall be conducted in accordance with MIL-STD-105 and as specified herein. Unit of product for examination purposes shall be one syringe as specified. S
13、ampling shall be inspection level II with an Acceptable Quality Level (AQL) of 1.0. 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-54837 . 9999974 OL43b29 752 A-A-5 4 8 3 7 Tests. Tests shall be conducted to determine compliance with specifica
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DODAA548371993SYRINGEIRRIGATINGGLASS 玻璃 注射器 PDF

链接地址:http://www.mydoc123.com/p-701781.html