DLA MIL-E-1 190 K-2013 ELECTRON TUBE RECEIVING TYPE 6112.pdf
《DLA MIL-E-1 190 K-2013 ELECTRON TUBE RECEIVING TYPE 6112.pdf》由会员分享,可在线阅读,更多相关《DLA MIL-E-1 190 K-2013 ELECTRON TUBE RECEIVING TYPE 6112.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、AMSC N/A FSC 5960 MIL-E-1/190K 17 September 2013 SUPERSEDING MIL-E-1/190J 21 February 2003 MILITARY SPECIFICATION SHEET ELECTRON TUBE, RECEIVING TYPE 6112 This specification is approved for use by all Departments and Agencies of the Department of Defense. The requirements for acquiring the electron
2、tube described herein shall consist of this document and MIL-PRF-1. DESCRIPTION: Twin triode, subminiature, high Mu. Outline - 3-1 (EIA). Base - E8-10. Envelope - T3. Cathode - Coated unipotential. Base connections: Pin No. - 1 2 3 4 5 6 7 8 Element - 2a 2g h 2k 1k h 1g 1a ABSOLUTE RATINGS: Paramete
3、r: Ef Eb Ec Ehk Rk/k Rg/g Ib/a Pp/a TE Alt Unit: V V dc V dc v Ohms Meg mAdc W C ft Maximum: 6.6 165 0, -55 200 - 1.1 3.3 0.30 +220 See Note 1 Minimum: 6.0 - - - - - - - - - Test Conditions: 6.3 100 0 0 1,500 - - - - - GENERAL: Qualification Not required. First article test is required and shall con
4、sist of all tests in table I with a sample size of 2 for a lot size less than or equal to 150 units and a sample size of 4 for a lot size greater than or equal to 151 units. All samples shall pass conformance inspection part 1 of table I before continuing. Half of the samples shall then be subjected
5、 to conformance inspection part 2, and the remaining samples shall be subjected to part 3, with no test failures permitted during any testing. After first article approval, acceptance testing shall consist of conformance inspection part 1 of table I with sample size in accordance with table III, cat
6、egory XVI (acceptance level 10.0) of MIL-PRF-1. INCH-POUND Inactive for new design after 7 March 1997. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-E-1/190K 2 TABLE I. Testing and inspection. Requirement or test MIL-STD-1311 Method Conditions
7、Symbol Limits Units Min Max Conformance inspection, part 1 Electrode current (1) (anode) 1256 See note 2 and 3 Ib 0.5 1.10 mA dc Electrode current (2) (anode) 1256 Ec = -2.8 V dc; Rk = 0 (see note 2) Ib - 50 A dc Total grid current 1266 Eb = 150 V dc; Ec = 0; Rk/k = 820 ohms; Rg/g = 1.0 Meg (see not
8、es 2 and 3) Ic 0 -0.3 A dc Heater current 1301 If 280 320 mA Transconductance (1) 1306 See note 2 Sm 1,500 2,100 mhos Heater-cathode leakage 1336 See note 2 Ihk - 5.0 A dc Short and discontinuity detection 1201 - - - - Conformance inspection, part 2 Insulation of electrodes 1211 See note 2 - 50 - -
9、Low-frequency vibration 1031 Rp = 10,000 ohms; E = 40 Hz; 15 G (see note 2) Ep - 25 mV ac Audio frequency noise 1246 Esig = 45 mV ac; Rg = 0.5 Meg; Rp = 0.2 Meg; Rk = 750 ohms; (see note 4) EB - 17 vu Grid currents 1266 Ef = 7.5 V; Ec = -4.0 V dc; Eb = 150 V dc; Rk = 0; Rg/g = 1.0 Meg (see notes 2 a
10、nd 5) Ic 0 -0.5 A dc Transconductance (2) 1306 Ef = 5.7 V (see note 2) Sm Ef - 15 % Amplification factor 1316 See note 2 Mu 60 80 - AC amplification 1321 Ebb = 100 V dc; Ecc = 0; Esig = 0.2 V ac; Rk = 0 (see note 2) Ep 8.0 - V ac Provided by IHSNot for ResaleNo reproduction or networking permitted w
11、ithout license from IHS-,-,-MIL-E-1/190K 3 TABLE I. Testing and inspection - Continued. Requirement or test MIL-STD-1311 Method Conditions Symbol Limits Units Min Max Conformance inspection, part 2 -Continued Direct-inter-electrode capacitance 1331 No shield (see note 2) No shield (see note 2) No sh
12、ield; section 1 No shield; section 2 No shield; No shield Cgp Cin Cout Cout Cgg Cpp 0.8 1.30 0.16 0.21 - - 1.20 2.10 0.30 0.35 0.014 0.80 pF pF pF pF pF pF Lead fatigue 1116 - - - - Envelope strain 2126 - - - - Shock 1041 450 G; EhK = +100 V dc; Rg = 0.1 Meg; (see note 6) - - - - Vibration fatigue 1
13、031 2.5 G; fixed frequency; F = 25 min, 60 max - - - - Post-shock and vibration-fatigue test end points: - Low-frequency vibration 1031 Ep - 100 mV ac Heater-cathode leakage 1336 Ihk - 20 A dc Change in transconductance (1) of individual tubes 1306 Sm t - 20 % Permanence of marking 1105 Conformance
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAMILE1190K2013ELECTRONTUBERECEIVINGTYPE6112PDF

链接地址:http://www.mydoc123.com/p-691298.html