DLA MIL-DTL-83725 D-2011 RELAYS VACUUM GENERAL SPECIFICATION FOR.pdf
《DLA MIL-DTL-83725 D-2011 RELAYS VACUUM GENERAL SPECIFICATION FOR.pdf》由会员分享,可在线阅读,更多相关《DLA MIL-DTL-83725 D-2011 RELAYS VACUUM GENERAL SPECIFICATION FOR.pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、Comments, suggestions or questions on this document should be addressed to DLA Land and Maritime, ATTN: VAT, Post Office Box 3990, Columbus, OH 43218-3990, or emailed to relaydla.mil. Since contact information can change, you may want to verify the currency of this address information using the ASSI
2、ST Online database at https:/assist.daps.dla.mil/. AMSC N/A FSC 5945 INCH-POUND MIL-DTL-83725D 7 October 2011 SUPERSEDING MIL-DTL-83725C 14 March 2002 DETAIL SPECIFICATION RELAYS, VACUUM, GENERAL SPECIFICATION FOR This specification is approved for use by all Departments and Agencies of the Departme
3、nt of Defense. 1. SCOPE 1.1 Scope. This specification establishes the general requirements for relays with vacuum dielectric (see 6.3) for use in high or low voltage circuits of electronic and electrical equipment (see 6.1). 1.2 Part or Identifying Number (PIN). The PIN consists of the letter “M“, b
4、asic specification number; specification sheet number, and an assigned dash number (see 3.1), as shown in the following example: M 83725 /5 -001 Military General Specification Dash designator specification sheet number number number 2. APPLICABLE DOCUMENTS 2.1 General. The documents listed in this s
5、ection are specified in sections 3 and 4 of this specification. This section does not include documents cited in other sections of this specification or recommended for additional information or as examples. While every effort has been made to ensure the completeness of this list, document users are
6、 cautioned that they must meet all specified requirements documents cited in sections 3 and 4 of this specification, whether or not they are listed. 2.2 Government documents. 2.2.1 Specifications, standards, and handbooks. The following specifications, standards, and handbooks form a part of this do
7、cument to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. FEDERAL FED-STD-H28 - Screw Thread Standards for Federal Services. DEPARTMENT OF DEFENSE STANDARDS MIL-STD-202 - Test Methods for Electronic and Electrica
8、l Component Parts. MIL-STD-1285 - Marking of Electrical and Electronic Parts. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-83725D 2 HANDBOOKS MIL-HDBK-454 - Electronic Equipment, General Guidelines for. (Copies of these documents are avail
9、able online at https:/assist.daps.dla.mil/quicksearch or from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.) 2.2 Non-Government publications. The following documents form a part of this document to the extent specified herein. Unless otherwise
10、 specified, the issues of these documents are those cited in the solicitation or contract. AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI) ANSI J-STD-004 - Requirements for Soldering Fluxes. (Application for copies can be found online at http:/www.ansi.org/ or 25 West 43rd Street, New York, NY 10036-80
11、02, telephone 212-642-4900, fax 212-302-1286) 2.3 Order of precedence. Unless otherwise noted herein or in the contract, in the event of a conflict between the text of this document and the references cited herein (except for related specification sheets), the text of this document takes precedence.
12、 Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 Specification sheets. The individual item requirements shall be as specified herein and in accordance with the applicable specification sheet. In the even
13、t of any conflict between the requirements of this specification and the specification sheet, the latter shall govern. 3.2 Qualification. The relays furnished under this specification shall be a product which has been tested, and has passed the qualification inspection specified herein, and has been
14、 listed on or approved for listing on the applicable Qualified Products List (QPL). 3.3 Materials. Materials shall be as specified herein. However, when a definite material is not specified, a material shall be used which will enable the relay to meet the performance requirements of this specificati
15、on. Materials used shall be fungus inert (see 6.6), self-extinguishing; and shall not support combustion, give off noxious gases in harmful quantities, give off gases in quantities sufficient to cause explosion of sealed enclosures, cause contamination to any part of the relay, or form current carry
16、ing tracks when subjected to any of the tests specified herein. The selection of materials shall be such as to provide maximum shelf life. After qualification, any change of parts or material shall be submitted to the Government qualifying activity for approval. Acceptance or approval of any constit
17、uent material shall not be construed as a guaranty of the acceptance of the finished product. 3.3.1 Metals. Metals shall be of a corrosion-resistant type or shall be plated or treated to resist corrosion. The use of mercury or mercury compounds is prohibited. The use of magnesium or magnesium alloys
18、 is prohibited (not applicable to contact systems). Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-83725D 3 3.3.1.1 Plated finishes. a. Pure tin plating as an underplate or final finish, is prohibited both internally and externally. Tin cont
19、ent of (product) and solder shall not exceed 97 percent, by mass. Tin shall be alloyed with a minimum of 3 percent lead, by mass (see 6.8). b. Pure zinc plating is prohibited internally and externally. c. Pure cadmium plating is prohibited internally and externally. 3.3.1.2 Dissimilar metals. When d
20、issimilar metals are used in intimate contact with each other, protection against electrolysis and corrosion shall be provided. The use of dissimilar metals in contact, which tends toward active electrolytic corrosion (particularly brass, copper, or steel used in contact with aluminum or aluminum al
21、loy), is not acceptable. However, metal spraying or metal plating of dissimilar base metals to provide similar or suitable abutting surfaces is permitted. Dissimilar metals should be as defined in 6.5. In hermetic seals, the 0.25 volt difference between the header material and the housing material i
22、s not applicable. 3.3.2 Magnet wire. Magnet wire shall be of such quality as to ensure that the relay meets all the performance requirements of this specification. 3.3.3 Plastic. Plastic shall be of such quality as to ensure that the relay meets all the performance requirements of this specification
23、 3.3.4 Ceramic. Ceramic shall be of such quality as to ensure that the relay meets all the performance requirements of this specification. 3.3.5 Recycled, recovered, or environmentally preferable materials. Recycled, recovered, or environmentally preferable materials should be used to the maximum ex
24、tent possible provided that the material meets or exceeds the operational and maintenance requirements, and promotes economically advantageous life cycle costs. 3.4 Interface and construction. Relays shall meet the interface and construction requirements specified in 3.1 (weight, physical dimensions
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAMILDTL83725D2011RELAYSVACUUMGENERALSPECIFICATIONFORPDF

链接地址:http://www.mydoc123.com/p-691212.html