DLA A-A-59375-2000 FURNACES HEAT-TREATING ELECTRIC NATURAL ATMOSPHERE BOX TYPE [Superseded DLA MIL-F-80258 A CANC NOTICE 1 DLA MIL-F-80258 A DLA MIL-F-80258]《盒型大气电热处理熔炉 [代替 DLA MIL.pdf
《DLA A-A-59375-2000 FURNACES HEAT-TREATING ELECTRIC NATURAL ATMOSPHERE BOX TYPE [Superseded DLA MIL-F-80258 A CANC NOTICE 1 DLA MIL-F-80258 A DLA MIL-F-80258]《盒型大气电热处理熔炉 [代替 DLA MIL.pdf》由会员分享,可在线阅读,更多相关《DLA A-A-59375-2000 FURNACES HEAT-TREATING ELECTRIC NATURAL ATMOSPHERE BOX TYPE [Superseded DLA MIL-F-80258 A CANC NOTICE 1 DLA MIL-F-80258 A DLA MIL-F-80258]《盒型大气电热处理熔炉 [代替 DLA MIL.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、pzq A-A-59375 27June2000 SUPERSEDING 28 October 1986 MIL-F- 8025 SA COMMERCIAL ITEM DESCRIPTION FURNACES, HEAT-TREATING, ELECTRIC, NATURAL ATMOSPHERE, BOX TYPE The General Services Administration has authorized the use of this commercial item description for all federal agencies. 1. SCOPE. This comm
2、ercial item description (CID) covers electric box type furnaces intended for use in heat-treating shops for hardening, tempering, normalizing, and annealing metal parts in a natural atmosphere. Furnaces covered by this CID are not intended for atmosphere control use. 2. CLASSIFICATION. The furnaces
3、shall be of the following types, styles, classes, and sizes. The type, style, class, and size to be furnished shall be as specified (see 7.2(b). The chamber depth for the type I furnace shall be as specified (see 7.2(c). Type I - Single chamber (style A or style B) Type II - Double chamber (style A
4、lower chamber and style B upper chamber) Style A - Forced air convection design Class 1 - 1200 OF to 1250 OF maximum operating temperature Class 2 - 1400 OF maximum operating temperature Style B - Radiation design Class 2 - 1400 OF maximum operating temperature Class 3 - 2000 OF maximum operating te
5、mperature Class 4 - 2200 OF to 2300 OF maximum operating temperature Class 5 - 2750 OF maximum operating temperature Size and depth - The chamber width, height, and depth are shown in tables I through III. Beneficial comments, recommendations, additions, deletions, clarifications, etc., and any data
6、 which may improve this document should be sent to: Defense Supply Center Richmond, ATTN: DSCR-VBD, 8000 Jefferson Davis Highway, Richmond, VA 23297-5610. AMSC NIA FSC 3424 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. Provided by IHSNot for ResaleNo reproduction
7、or networking permitted without license from IHS-,-,-A-A-59375 TABLE II. Sizes of type I, style B furnaces. 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59375 Size o1 TABLE II. Sizes of type I, style B furnaces (continued). Lower furnace Upp
8、er furnace Chamber dimensions, Chamber dimensions, Width Height Depth Width Height Depth Style Class inches Style Class inches 2 12 12 11 3 12 12 12 TABLE III. Sizes of type II furnaces. 121 12 I 12 I 17 I 2 12 12 23 2 12 12 29 2 18 18 24 A 2 18 18 36 B 11 19 I 12 I 19 11 10 I 10 I 24 1 12 12 36 1 1
9、9 12 19 131 12 I 12 I 18 I 3 12 12 24 3 12 12 30 10 10 24 I I 4 12 12 36 4 19 12 19 3. SALIENT CHARACTERISTICS 3.1 General requirements. The furnace shall be new and one of the manufacturers current models capable of operation in accordance with the requirements herein. All parts subject to wear, br
10、eakage, or distortion shall be accessible for adjustment, replacement, and repair. The furnace shall be a box design having electrical heating elements, a hearth to support the load, and a single opening in the end of the chamber for loading and unloading on a horizontal plane. 3.1.1 Furnace type. T
11、he type I furnace shall have a single chamber of either a style A forced air convection design or a style B radiation design. The type II furnace shall have a double chamber (overhnder) with a style A lower chamber and a style B upper chamber. 3 Provided by IHSNot for ResaleNo reproduction or networ
12、king permitted without license from IHS-,-,-A-A-59375 3.1.2 Furnace stvle. The style A furnace shall use forced air convection to heat the load. Air shall be heated in an area separated from the load and blown into the chamber by one or more fans. The load shall not be exposed to radiant heat from t
13、he electrical heating elements. The style B furnace shall use radiation to heat the load by direct exposure to the electrical heating elements. 3.2 Components. All the furnaces shall include, as a minimum, the following components: 3.2.1 Frame. The furnace shall have a structural frame that shall pr
14、ovide stable support for the chamber, hearth, and maximum rated load. A floor-mounted furnace shall have provisions for being lifted by a forklift. 3.2.2 Shell. The outer shell of the furnace shall be constructed of reinforced sheet steel and have welded or riveted joints to provide a rigid structur
15、e. 3.2.3 Hearth. Unless otherwise specified (see 7.2(d), the hearth shall be constructed of heat- conducting material considered by the manufacturer as standard. The hearth shall be capable of supporting rated loads at the furnace maximum operating temperature without permanent distortion. If requir
16、ed, rollers or slide rails shall be provided for moving the load in and out of the chamber as specified (see 7.2(e). If required, the furnace shall be provided with the number and arrangement of removable shelves as specified (see 7.2(f). 3.2.4 Lining. The furnace chamber and door lining shall be ra
17、ted for the furnace maximum operating temperature and shall have insulating properties that maintain the furnace exterior surface temperature at or below the temperature shown in table IV. 3.2.5 Door. The furnace shall have a door-operated interlock switch that turns off the power to the heating ele
18、ments when the door is opened. The door of a class 1 or 2 furnace shall be mounted on hinges and swing open. The door of a class 3,4, or 5 furnace shall open by being lifted vertically either by manual means with a suitable counterweight(s) or by a power-operated system as specified (see 7.2(g). The
19、 door mechanism shall move the door away from the face of the furnace a sufficient distance to prevent damage to the chamber perimeter seal or to the lining during lifting and lowering. The door hot side shall face away from the operator at all times during lifting and lowering. 3.2.6 Temperature co
20、ntroller. Unless otherwise specified (see 7.2(h), the furnace shall have a microprocessor-based programmable temperature controller that meets the requirements of sections 5-3 and 5-18.2 of National Fire Protection Association (NFPA) 86, “Standard for Ovens and Furnaces“ (DoD adopted). The temperatu
21、re controller shall maintain the furnace chambers temperature at the control thermocouple within k 2 OF of the set temperature. If required, ramp and soak period software programs for process temperature control shall be provided as specified (see 7.2(i). The temperature controller shall have an ext
22、ernal dual 120-volt, single-phase, 60- hertz outlet for powering a process data recorder or other process monitor. 3.2.7 Excess temperature controller. Unless otherwise specified (see 7.2j), an excess temperature controller independent of the temperature controller shall be provided. The excess temp
23、erature controller shall automatically turn off the heating elements when the chamber temperature rises above the set temperature by an incremental temperature selectable within a range of 50 OF to 100 OF. 4 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IH
24、S-,-,-A-A-59375 Style 3.2.8 Electrical svstem. Unless otherwise specified (see 7.2(k), the electrical system shall conform to the NFPA 70, “National Electrical Code“ (DoD adopted), and NFPA 86 sections 4-6 and 5-18. The furnace shall be wired for operation from a 230- or 460-volt, 3-phase, 60-hertz
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAAA593752000FURNACESHEATTREATINGELECTRICNATURALATMOSPHEREBOXTYPESUPERSEDEDDLAMILF80258ACANCNOTICE1DLAMILF80258ADLAMILF80258

链接地址:http://www.mydoc123.com/p-687308.html