BS EN 15267-1-2009 Air quality - Certification of automated measuring systems - Part 1 General principles《空气质量 自动化测量系统的证书 通用原理》.pdf
《BS EN 15267-1-2009 Air quality - Certification of automated measuring systems - Part 1 General principles《空气质量 自动化测量系统的证书 通用原理》.pdf》由会员分享,可在线阅读,更多相关《BS EN 15267-1-2009 Air quality - Certification of automated measuring systems - Part 1 General principles《空气质量 自动化测量系统的证书 通用原理》.pdf(20页珍藏版)》请在麦多课文档分享上搜索。
1、BS EN15267-1:2009ICS 13.040.99NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBRITISH STANDARDAir quality Certification ofautomated measuringsystemsPart 1: General principlesThis British Standardwas published under theauthority of the StandardsPolicy and StrategyCommittee on 30
2、 April2009 BSI 2009ISBN 978 0 580 57914 1Amendments/corrigenda issued since publicationDate CommentsBS EN 15267-1:2009National forewordThis British Standard is the UK implementation of EN 15267-1:2009.The UK participation in its preparation was entrusted to TechnicalCommittee EH/2/1, Stationary sour
3、ce emission.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisionsof a contract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immu
4、nityfrom legal obligations.BS EN 15267-1:2009EUROPEAN STANDARDNORME EUROPENNEEUROPISCHE NORMEN 15267-1March 2009ICS 13.040.99English VersionAir quality - Certification of automated measuring systems - Part1: General principlesQualit de lair - Certification des systmes de mesurageautomatiss - Partie
5、1 : Principes gnrauxLuftbeschaffenheit - Zertifizierung von automatischenMesseinrichtungen - Teil 1: GrundlagenThis European Standard was approved by CEN on 14 February 2009.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this Europ
6、eanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the CEN Management Centre or to any CEN member.This European Standard exists in three official versions (English,
7、French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as theofficial versions.CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus
8、, Czech Republic, Denmark, Estonia, Finland,France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMIT EU
9、ROPEN DE NORMALISATIONEUROPISCHES KOMITEE FR NORMUNGManagement Centre: Avenue Marnix 17, B-1000 Brussels 2009 CEN All rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 15267-1:2009: EBS EN 15267-1:2009EN 15267-1:2009 (E) 2 Contents Page Forewo
10、rd 3 Introduction .4 1 Scope 5 2 Normative references 5 3 Terms and definitions .6 4 Abbreviations .7 5 Principles 7 5.1 Performance testing of the automated measuring system .7 5.2 Initial assessment of the AMS manufacturers quality management system .8 5.3 Certification 8 5.4 Surveillance 8 6 Role
11、s and responsibilities 9 6.1 General 9 6.2 Roles and responsibilities of the manufacturer .9 6.3 Roles and responsibilities of the test laboratory .9 6.4 Roles and responsibilities of the relevant body 10 7 Certification procedure 11 7.1 General . 11 7.2 Performance testing of the automated measurin
12、g system 11 7.3 Initial assessment of the manufacturers quality management system . 11 7.4 Certification . 11 7.5 Surveillance . 12 7.6 Review of certifications 13 Annex A (informative) Application and assessment processes 14 Annex B (informative) Example certificate template . 15 Bibliography . 17
13、BS EN 15267-1:2009EN 15267-1:2009 (E) 3 Foreword This document (EN 15267-1:2009) has been prepared by Technical Committee CEN/TC 264 “Air quality”, the secretariat of which is held by DIN. This European Standard shall be given the status of a national standard, either by publication of an identical
14、text or by endorsement, at the latest by September 2009, and conflicting national standards shall be withdrawn at the latest by September 2009. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held r
15、esponsible for identifying any or all such patent rights. This document is Part 1 of a series of European Standards: EN 15267-1, Air quality Certification of automated measuring systems Part 1: General principles EN 15267-2, Air quality Certification of automated measuring systems Part 2: Initial as
16、sessment of the AMS manufacturers quality management system and post certification surveillance for the manufacturing process EN 15267-3, Air quality Certification of automated measuring systems Part 3: Performance criteria and test procedures for automated measuring systems for monitoring emissions
17、 from stationary sources According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary,
18、Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. BS EN 15267-1:2009EN 15267-1:2009 (E) 4 Introduction The certification of automated measuring systems (AMS) supports t
19、he requirements of certain Directives of the European Union (EU), which require, either directly or indirectly, that AMS comply with performance criteria, maximum permissible measurement uncertainties and testing requirements. These Directives include the Directive on the limitation of emissions of
20、certain pollutants into the air from large combustion plants 1, the Directive on the incineration of waste 2 and the Framework Directive on ambient air quality assessment and management 3 and the associated daughter directives 4, 5, 6 and 7. The responsibility for approving AMS for monitoring ambien
21、t air quality under Directive 96/62/EC lies with the national competent authority or a body designated by the EU member state. No explicit requirement for approving AMS for monitoring emissions from stationary sources is defined in the relevant EU Directives, although the competent authorities in so
22、me EU member states have such arrangements in place. In some EU member states the competent authority delegates the responsibility for approval of AMS to a certification body accredited to EN 45011 by national accreditation bodies. In some EU member states the competent authority cannot be accredite
23、d by external bodies, in others they may be. These approaches have built up over many years and reflect the different administrative and legal arrangements that exist in the EU member states. In order to recognize these different approaches, this European Standard uses the collective term “relevant
24、body” when referring to competent authority or certification body. The terms “competent authority” and “certification body” are only used where it is necessary to be specific for the purpose of clarity in the way in which a requirement applies under the different approaches. The European Standard EN
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN1526712009AIRQUALITYCERTIFICATIONOFAUTOMATEDMEASURINGSYSTEMSPART1GENERALPRINCIPLES 空气质量 自动化 测量 系统

链接地址:http://www.mydoc123.com/p-573047.html