1、Designation: F2927 12Standard Test Method forDoor Systems Subject to Airblast Loadings1This standard is issued under the fixed designation F2927; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number i
2、n parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method identifies the standard procedures thatshall be followed when utilizing either a shock tube or acontrolled open-air explosion
3、to evaluate the blast capacity ofa door system. This test method is designed for all types ofswinging doors, including single and double doors construc-tion. This method is used to test complete door assemblies. Adoor assembly includes the door panel(s), latching hardware,hinges, post mullion (if ap
4、plicable), frame and frame connec-tion to a rigid reaction structure. The door panel(s) may alsocontain one or more integral vision lites (glazing systems). Theglazing system may include, but not be limited to thosefabricated from monolithic glass, laminated glass, plastic,glass-clad plastics, glass
5、/plastic glazing materials, and filmed-backed glass. The results gathered from this method can beused for door installations in non-rigid wall openings. The testmethod may be adapted to horizontal sliding and vertical-liftdoors.1.2 The scaled range or standoff of the charge shall be 1 m(3 ft, 3 in.)
6、 or greater from the specimen in order to reduce oreliminate any punching effect the blast may have on thespecimen. A charge-in-contact blast test is not covered by thismethod.1.3 This test method and the resulting data are valid for thedoor size tested and smaller doors of identical construction.Ac
7、ceptance criteria are divided into five Door ResponseDamage Categories (Categories I, II, III, IV and V). Refer tosection 7.1 and Table 1 for a description of each category.1.4 A door assembly may also contain ancillary hardwaresuch as pulls, closers, kickplates, coordinators, gaskets, etc.Although
8、these hardware components may not influence blastresistance performance, the specifier may wish to verify thatthese items do not dislodge from the door or frame during a testand become a flying debris hazard.1.5 For doors equipped with a vision lite, the door shall beevaluated using the Door Respons
9、e Damage Categories intro-duced in section 1.3 and defined in Table 1 and the glazing andglazing system of the vision lite shall also be evaluated usinga No Break, No Hazard, Minimal Hazard, Very Low Hazard,Low Hazard and High Hazard rating system. Refer to section7.5 and Table 2 for glazing hazard
10、definitions.1.6 This method is intended to test the blast capacity of adoor assembly from a shock wave. It does not attempt toaddress all testing required of door assemblies. These tests mayinclude, but are not limited to, charge-in-contact blastresistance, forced entry resistance, bullet resistance
11、, fireresistance, sound attenuation, and gas or water leakage. Thesetypes of tests are not covered by this test method.1.7 This test method does not verify the blast performanceof the wall that a tested door will be placed in.1.8 The values stated in SI units (International System ofUnits) are to be
12、 regarded as the standard. The values given inparentheses are provided for information only.1.9 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health pract
13、ices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E699 Practice for Evaluation of Agencies Involved inTesting, Quality Assurance, and Evaluating of BuildingComponentsF1642 Test Method for Glazing and Glazing Systems Sub-ject to Ai
14、rblast Loadings2.2 Other Standards:3ISO/IEC International Standard 17025 General Require-ments for the Competence of Testing and CalibrationLaboratories3. Terminology3.1 Definitions:1This test method is under the jurisdiction ofASTM Committee F12 on SecuritySystems and Equipment and is the direct re
15、sponsibility of Subcommittee F12.10 onSystems Products and Services.Current edition approved Oct. 1, 2012. Published November 2012. DOI:10.1520/F2927-12.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMSt
16、andards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohock
17、en, PA 19428-2959. United States1TABLE 1 Door Response Damage Categories and DescriptionsDamage Rating Description of Door / Frame ResponseDamage LevelCategoryUndamaged The door specimen is substantially unchanged after the airblast loading and is fullyoperable. Any permanent deformation shall be wi
18、thin 3 mm (18 in.) of the pretestcondition. The door must be checked that it is operable by unlatching and swingingthe door open and then closed and latched. The door can be secured. The externalportion of the frame, frame anchorage, latches, and hinges shall not show any visibledamage. If strain ga
19、uges were used, the recorded stresses in the door material arewithin the specifiers acceptable limits.IDamaged butOpenableThe door panel, the frame, and/or the hardware has acceptable permanentdeformation or damage; however, the door remains openable. The door must bechecked that it is openable by u
20、nlatching and swinging the door open far enough toallow ingress / egress. Acceptable permanent deformation or damage and degree ofopening to permit ingress / egress is determined by the specifier based on the enduse of the door.IINon-catastrophicFailureThe door may get lodged into the frame from the
21、 blast force or the door may swingopen in rebound. The door may be inoperable and may hinder ingress / egress.Acceptable permanent deformation or damage is determined by the specifier basedon the end use of the door. The door and hardware components are not permitted todetach from the frame and be t
22、hrown into the test structure witness area. The frameand frame anchorage must remain and integral system and attached to the teststructure wall.IIILimited Hazard Failure The door leaf becomes separated frame or the frame anchorage fails and the entiredoor leaf and frame assembly become separated fro
23、m the test structure wall and arethrown into the test structure witness area. The dislodged door leaf or assembly mustremain within the3m(120in.)finishfloor as shown in Fig. 1. There shall be noevidence of any dislodged hardware component striking the witness panel mountedon the back wall of the tes
24、t structure. Note: A door assembly equal to or exceeding 3m (120 in.) in height cannot obtain a “Limited Hazard Failure Category IV Rating”due to the size limitation of the test structure witness area.IVHigh Hazard Failure The door leaf becomes separated frame or the frame anchorage fails and the en
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF29272012STANDARDTESTMETHODFORDOORSYSTEMSSUBJECTTOAIRBLASTLOADINGS 承接 空气 爆破 负载 系统 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-539750.html