《ASTM F2137-2004 Standard Practice for Measuring the Dynamic Characteristics of Amusement Rides and Devices《娱乐骑座装置和设备动力特性测量的标准实施规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM F2137-2004 Standard Practice for Measuring the Dynamic Characteristics of Amusement Rides and Devices《娱乐骑座装置和设备动力特性测量的标准实施规范》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F 2137 04Standard Practice forMeasuring the Dynamic Characteristics of AmusementRides and Devices1This standard is issued under the fixed designation F 2137; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of
2、last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers acquisition of data related to thedynamic characteristics of amusement rides and devices.1.2 Thi
3、s practice also defines the specific requirements of aStandardized Amusement Ride Characterization Test (SARCTest) for use in characterizing the dynamic motion of anamusement ride or device.2. Referenced Documents2.1 SAE Standard:SAE J211 Instrumentation for Impact Tests23. Terminology3.1 Definition
4、s:3.1.1 aliasinga phenomenon associated with sampleddata systems, wherein a signal containing significant energy atfrequencies greater than one half of the system sample fre-quency manifests itself in the sampled data as a lowerfrequency (aliased) signal. Aliasing can be avoided only bylimiting the
5、frequency content of the signal prior to thesampling process. Once a signal has been aliased, it is notpossible to reconstruct the original signal from the sampleddata.3.1.2 calibration constantthe arithmetic mean of the sen-sitivity coefficients, evaluated at frequencies that are evenlyspaced on a
6、logarithmic scale between FLand FH.3.1.3 calibration valuethe ratio of the reference calibra-tion system output, in engineering units relevant to the trans-ducer, to the data channel output, in volts, as measured atconstant excitation frequency and amplitude.3.1.4 channel frequency class (CFC)a freq
7、uency responseenvelope that conforms to Fig. 1 and is referred to by the valueFHin hertz. The CFC frequency response envelope is definedby the boundaries shown in Fig. 1 and the following charac-teristic frequencies:FLPass band lower limit (hertz). Always equal to zero(0.0) hertz.FHPass band upper l
8、imit (hertz). The CFC designator.FNThe corner or knee of the frequency response envelope.Always equal to or greater than 1.667 3 FH.FSThe minimum sample frequency for a sampled datasystem that corresponds to the designated CFC. Always equalto or greater than 12 3 FH.3.1.4.1 DiscussionFL, FH, FN, and
9、 FSare always specifiedin hertz. While the characteristics of the CFC may be appliedto individual components of a data channel, the CFC is, bydefinition, the frequency response envelope of the entire datachannel from the mounted transducer to the final representationof the acquired data.3.1.5 coordi
10、nate systemthree orthogonal axes that inter-sect at an origin whose positive directions correspond to theright-hand rule.3.1.5.1 measurement coordinate systema coordinate sys-tem that provides the reference axes and sign convention forthe test data record(s).3.1.5.2 patron coordinate systema coordin
11、ate system thatis fixed with respect to the human upper torso and oriented asin Fig. 2.3.1.5.3 vehicle coordinate systema coordinate system thatis fixed with respect to the ride or device being tested.3.1.6 data channelthe entire instrumentation system for asingle channel of data acquisition; from t
12、he transducer to thefinal representation of the data, including all post-acquisitiondata processing that may alter the amplitude or frequencycontent of the data.3.1.7 data channel full scalethe maximum usable value,in units of the physical phenomenon being measured, that maybe represented by a data
13、channel. This value is determined bythe data channel component with the lowest full-scale range.3.1.8 free-run timea period of time during the ride cyclewhen no energy is added to the ride vehicle.3.1.9 full-scalethe maximum usable value, in units of thephysical phenomenon being measured, which may
14、be repre-sented by a data channel or some component thereof.3.1.10 “g”the standard acceleration due to gravity at thesurface of the earth. Defined as 32.2 ft/s/s or 9.81 m/s/s.3.1.11 nonlinearitythe ratio, in percent, of the maximumdifference between a calibration value and the corresponding1This pr
15、actice is under the jurisdiction of ASTM Committee F24 on AmusementRides and Devices and is the direct responsibility of Subcommittee F24.10 on TestMethods.Current edition approved May 1, 2004. Published May 2004. Originallyapproved in 2001. Last previous edition approved in 2001 as F 2137 01.2Avail
16、able from Society of Automotive Engineers, 400 Commonwealth Drive,Warrendale, PA 15096.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.value determined from the straight line defined by the sensi-tivity coefficient and zero bias.3.1.
17、12 reference calibration systemthe entire calibrationinstrumentation system from the reference transducer to theoutput device that provides the calibration excitation value inengineering units appropriate to the physical phenomenonbeing measured.3.1.13 resolutionthe lowest magnitude data channel out
18、-put value that can be identified as non-zero.3.1.14 sensitivity coeffcientthe slope of the straight linerepresenting the best fit, as determined by the method of leastsquares, to calibration values generated at a single frequencyand at various amplitudes within the data channel full scalerange. In
19、the special case where only a single calibration valueis considered, the sensitivity coefficient and the calibrationvalue will be equal.3.1.15 standardized amusement ride characterization test(SARC Test)an instrumented test of an amusement ride orFIG. 1 Frequency Response EnvelopeFIG. 2 Patron Coord
20、inate SystemF2137042device that is done in conformance to the general specificationsof this standard and the particular specifications of Section 12.3.1.16 test data recordthe uninterrupted time record ofdata channel value(s) that results from a data acquisitionsession. the length of a data acquisit
21、ion session is not specified.The data acquisition session is considered complete (or inter-rupted) when data is not recorded for a time interval longerthan the sampling period of the data recorder. Both a strip chartpaper record and a computer data file containing periodicallysampled data channel va
22、lues are typical forms of a test datarecord.3.1.17 test documentationthe entire body of documenta-tion pertaining to a test performed in compliance with thispractice, including, but not limited to, the test data record(s),data channel specifications and other test specifications, andinformation as p
23、rovided in this practice (see Section 11 and12.1.9).3.1.18 transducerthe device at the front end of the datachannel that converts a physical phenomenon, such as accel-eration, to a calibrated electrical signal that may be input to theremainder of the data channel.3.1.19 transverse sensitivitythe sen
24、sitivity of a rectilineartransducer to excitation along an axis that is perpendicular toits nominal sensitive axis.3.1.20 zero biasthe magnitude of the data channel outputwhen the transducer input is zero or static.4. Significance and Use4.1 This practice is intended for use whenever the dynamicchar
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF21372004STANDARDPRACTICEFORMEASURINGTHEDYNAMICCHARACTERISTICSOFAMUSEMENTRIDESANDDEVICES 娱乐 装置 设备

链接地址:http://www.mydoc123.com/p-537839.html